There is no way to completely reset the Digitrax DCS100 or DCS200 Command Station/Booster using Option Switches such as Option Switch 39. Option Switch 39 resets Locomotive Registry, Consists, etc. associated with DCC equipped locos by resetting mobile decoder info (that is in the command station) and consists, routes and loco roster info. It does not necessarily reset other Option Switches as expected. A complete reset of the DCS100 and DCS200 to factiory defaults is only accomplished by removing input power and removing the battery. This involves disconnecting the grey terminal plug then removing the metal cover by unscrewing the ...
There are times, when all else has failed, that it is best to simply start over. To reset Super Chief, you can use the Chief's option switches to start fresh. *Special Instructions for DCS100 Op Switches 36, 37, 38, & 39 For Op Switch #36-#39 to work properly: In this example, a complete reset will occur (Option Switch 39). 1. Place the DCS100's MODE toggle switch on the DCS100 in the Center OP position 2. Press the SWCH key on the DT400/DT402/DT500 3. Press 3 and then press 9 4. Set the OpSw of choice to c by pressing the ...
Overview:To reset locomotive electronics to factory defaults the user must set CV08 to a value of 08. It is recommended that this procedure be performed on the dedicated service mode programming track using direct mode programming.* Note: This is the only programming procedure that we recommend using the programming track for. All other programming should be performed on the main track using Operations mode programming.Procedure:1. Place the DCC equipped locomotive on a dedicated service-mode programming track.* Note: The rails of this track should be connected to the PROG A & PROG B outputs on the DCS100 command station.2. Set the ...
Digitrax Series 3 and later mobile decoders are reset by setting CV08 to a value of 08 to reset everything or 09 to reset every thing EXCEPT the loadable speed table.Earlier Digitrax decoders require resetting each CV individually. To reset earlier Digitrax mobile decoders: Reset your decoder to the factory settings by going into program mode and manually resetting the following CVs to these values: CV01=03 CV29=06 CV03=00 CV04=00 CV02=00 CV05=00 CV06=00 If you set up loadable speed tables, you may also need to reset CV65=00 CV66=00 CV67=00 CV68-93=00 CV91=00 CV95=00
CV08 is the factory reset CV for all FX3 decoders and also the Manufacturer ID CV for all decoders.When you read the value of CV08, Digitrax decoders report back "129".To reset all CV values to their factory default, program CV08 to a value of 008 while the locomotive is on the programming track.To reset all CV values except for 28 step speed tables to their factory values set CV08 to a value of 009.Note: Performing a factory reset will not affect the manufacturer ID and will reset the decoder's address to the factory default of 03, a 2 digit address.
CV08 is the factory reset CV for all FX3 decoders and also the Manufacturer ID CV for all decoders. This procedure is performed on a programming track. To reset all CV values to their factory default, program CV08 to a value of 008/x08 while the locomotive is on the programming track. To reset all CV values except for 28 step speed tables to their factory values set CV08 to a value of 009/x09. Earlier Digitrax decoders must be reset manually, CV by CV. This procedure may or may not work with other manufacturer's decoders. When you "read" the value of ...
Resetting Factory Defaults You are unlikely to encounter a problem that will require a factory reset. One such instance may occur if you set a password for your Duplex Group name and forget what it is. Resetting to factory default condition is an easy way to correct the situation. Note: If you have more than one UR92 in your layout, you will want to disconnect all of them to do a full factory reset on each unit as follows. Once they have been reset, reconnected to your LocoNet, and allowed to renegotiate a common Group name; you can change the ...
To reset a non responsive MTH decoder follow these simple steps. 1. Place the locomotive on the Mainline track 2. Select address 55 3. Enter OPS mode programming 4. Select CV55 and a value of 55 5. Write to the decoder This will reset the decoder to address 03. Once reset, the decoder can be programmed. MTH decoders are best programmed in OPS mode programming on the Mainline. NOTE: When programming in OPS mode, remember to select the address of the locomotive you want to program or you risk programming all the locomotives on the layout. ...
There are times when it is necessary to reset the Super Empire Builder. Because this is a system reset, there are special instructions: There are different levels of system reset. OpSw 36: Clears all mobile decoder information, including locomotive consists. OpSw 38: Clears the locomotive roster (such as when you receive a "slot=max" error report). OpSw 39: Full reset, clears all internal memory states. The factory default setting for all DB150 option switches is t or "thrown" The Initial Procedure 1. Determine which DB150 option switch you want to change, 36, 38 or 39. 2. Move the Mode toggle switch on ...
To reset the DCS51/DCS50 to factory settings: If you change command station option switches and experience unexpected results, just set OpSw 39 to “c” (closed) to reset the unit to the original factory settings. 1. Press the PROG key. The display shows the last decoder programming mode used. 2. Press the SWITCH key. The display shows the last switch used and its commanded position. 3. Use the numeric keypad to enter the number of the Option Switch you want to change; in this case 39. 4. Press the "c - / CV-WR (lower right of keypad)" key to set the ...
Most Digitrax mobile decoders have a global reset function, which returns the decoder's CVs to their factory default settings.This is useful if the CV values in a particular decoder have been changed with less than wonderful results. For example, you may have accidentally set the CV value for acceleration so that the engine won't move for minutes when issued a speed command. This makes it look like the decoder is not working when all it needs is to have the CV value for acceleration reset. Many of the decoders that are sent to us for repair just need to have ...
Q: What is the exact reset procedure for a TF4? I tried both with series 3 procedure (CV8) and the other mobile decoders procedure with no success. My TF4 remains out of control. However, the white output makes the LED on my decoder testing board flicker. A: Since CV8 to 08 only works on series 3 and later decoders, it does not work on the function only decoders. TF4's CVs must be reset manually to factory values. The Factory Default Values are: CV64 000 CV61 002 CV49 000 CV50 000
If you want to reset the SE8C to its factory settings, follow this procedure: No track power is required for testing, but you will need a working LocoNet connection and throttle, or a PC running DCC control software that is connected to LocoNet. a. Press and hold the Option Button until the red LED starts to blink. b. Release the button, the red and green LEDs will blink alternately indicating that you are in Option Switch programming mode. c. Go into SWITCH mode on your throttle or PC. d. Select Switch 20. e. Close and then Throw the switch to ...
Digitrax command stations have Option Switches that care used to customize their operation. Command Station option switches should not be changed unless you fully understand what you are trying to accomplish. Information on these Option Switches is included in each command station's manual.Be sure that you are changing the correct Command Station Option Switches as the unit can be crippled by closing the wrong switches. NEVER CLOSE OPTION SWITCH #1!!Clearing your Command Station's Mobile Decoder SlotsMost command station problems are caused by filling up the command station's available slots by the following:1. Operators failing to zero the speed of unused ...
Performing factory decoder reset using Digitrax Zephyr Xtra (DCS51) or Zephyr (DCS50)Overview:To reset a Digitrax decoder to factory defaults the user must set CV08 to a value of 08. It is recommended that this procedure be performed on the dedicated service mode programming track using direct mode programming.Procedure:1. Place the decoder equipped locomotive on an electrically isolated service-mode programming track which is connected to Programming Outputs Prog 'A' & 'B'.2. Press the PROG MODE key until “dir” appears in the LED display.3. Press the STEPS CV key. (The LED display should read “t###” with the # symbols replaced by actual digits)4. Enter “08” using ...
Q: How do I reset the DS54 CV's to factory default values? A: Each DS54 CV must be manually reconfigured to set the DS54 to factory default values. The factory default values for the DS54's CVs are: CV01 = 1 All other programmable CVs = 0
In order to reset your WTL12 to the factory default setting as a Command Station/Throttle simply follow the steps below: Disconnect the power from the WTL12 unit Press and Hold the PWR key Reconnect the power while continuing to hold the PWR key Release the PWR key The WTL12 is now configured as a Command Station/Throttle. The power button will be lit up green on the right side.
When I plug in a DT402D throttle to LocoNet using a DCS240 as my Command Station, it flashes the display as normal then fades and continues to reset. Make sure you have a charged battery installed in your DT402D. The DT402D is attempting to power on the RF24 radio in the throttle and register with the UR92. Without a battery it cannot draw enough power from LocoNet to complete this procedure. If you plan to use your DT402D as a tethered throttle it is recommended that you use throttle options to turn off the throttles duplex radio capabilities. Press OPTN ...
Instructions below are for both DCS100 & DCS200 (DCS200 omitted in text for clarity).1. Refer to the DCS100 Option Switch Table to decide which option switches you want to change. Also note that there are special instructions for OpSw's 36, 37, 38, & 39. 2. Move the MODE toggle switch on the front of the DCS100 into the "OP" position . The LocoNet Railsync will go inactive & all other boosters plugged in to LocoNet, including the one that is built into the DCS100, will shut down. 3. Disconnect LocoNet from the DCS100 you are configuring. 4. Connect your DT300 ...
Note: These instructions are the same for DCS100 & DCS200 (DCS200 omitted for clarity).1. Refer to the DCS100 Option Switch Table to decide which option switches you want to change. Also note that there are special instructions for OpSw's 36, 37, 38, & 39. 2. Move the MODE toggle switch on the front of the DCS100 into the "OP" position . The LocoNet Railsync will go inactive & all other boosters plugged in to LocoNet, including the one that is built into the DCS100, will shut down. 3. Disconnect LocoNet from the DCS100 you are configuring. 4. Connect your DT400 ...
At the factory, your DS64 was set to control solenoid type turnout machines that use a single pulse output for operation. If you are using solenoid type turnouts, you can install the DS64 “out of the box.” If you have reconfigured your DS64 for stall motor type turnouts, the DS64 can be reconfigured back to solenoid type turnout motors.1. Connect the DS64’s ‘TRKA’ and ‘TRKB’ terminals to your track. No turnouts should be connected to the DS64 at this time.2. On the DS64 press and hold the OPS button down for about 3 seconds until the red OPS LED and ...
Testing for Tower 55 DCC Equipped Locos after 4 Digit address programming:Note these instructions are the same for both DCS50 Zephyr and DCS51 Zephyr Xtra1. Press the LOCO key on the DCS50. (The LED display should begin flashing)2. Enter the 4-digit address that was programmed in the procedure above using the numeric keypad. (The LED display should be flashing “####” with the # symbols replaced with the 4-digit address that was keyed in)3. Press the LOCO key on the DCS50. (The LED display should display “####” solid and the locomotive sounds should start up)4. Select FORWARD with the direction knob ...
The DCS100, 200, 240 and DB150 use several beeps and clicks that can be used as diagnostic tools that will help you debug a number of error conditions. DCS100/200 Audible Sounds 1 Beep DCS100/200 has powered on successfully or has sent a programming command. 3 Beeps A loco address has been "purged" due to non-use. This is informational only and is normal. 4 Beeps Booster short circuit shutdown. Fault Alarm. 6 Beeps Command station already present in system. When two command stations are operating on the same system, you may experience unexpected results. 7 Beeps DCS100/200 CMOS battery low ...
The DS64 is a powerful stationary decoder. If you have tried to program this stationary decoder and are having problems, there are several things that you can do before contacting Tech Support for further help. Is the DS64 receiving enough power? The DS64 can be powered in several different ways. Although it is possible to power the DS64 from track power, this has been a source of problems for many operators due to low voltage. This typically arises on a railroad that is using power in excess of the capacities of its power supplies. Have you programmed all four addresses ...
Before sending your Digitrax mobile decoder in for repair try these troubleshooting steps to see if you can “bring it back from the dead” and save a trip to the shop and possible repair charge. As with troubleshooting anything, begin checking what could be wrong methodically. Write down your observations as you work through the list to solve the problem.The most common "repair" problem we see in our repair department is decoders that are programmed incorrectly.Many decoders we receive for repair have been programmed with CV values that cause them to seem to have a problem. The good news-bad news ...
Before sending your Digitrax Command Station or Booster in for repair try these simple steps to see if you can “bring it back from the dead” and save a possible trip to the repair shop.1. Nothing is respondingIf there are NO LEDs lit on the front panel of the Command Station or Booster: Check the power supply to the unit to make sure that it has not been knocked loose in the power socket and that the socket is powered. Check the connections from the power supply to Track A and Track B connections on the front of the unit ...
Function Controls F9-F12 Some Broadway Limited Locomotives use Functions F0-F12 when running in DCC mode. In some cases F9-F12 do not respond properly. To remedy this problem, simply reset the locomotive to the factory default setting per the Broadway Limited Instructions you received with your locomotive. Note: F9-F12 are accessible on the DT400 throttle when used in conjunction with the DCS100 command station.
Function Controls F9-F12 Not Responding Properly on Broadway Limited LocomotivesSome Broadway Limited Locomotives use Functions F0-F12 when running in DCC mode. In some cases F9-F12 do not respond properly. To remedy this problem, simply reset the locomotive to the factory default setting per the Broadway Limited Instructions you received with your locomotive.Note: F9-F12 are accessible on the DT400 & DT402 series throttles when used in conjunction with the DCS100 command station.
More Locos, More power, More Fun! The DCS100 Command Station lets your LocoNet System run up to 120 locos and 120 throttles. Complete with full read/ write programming, route capability, and a separate programming output so you can run and program at the same time. The DCS100 is the base command station/booster for the Super Chief Xtra sets and is also available separately as an add on.
Many clubs use a DCS100/200 as a Booster in their setups. Digitrax does not recommend using a DCS100/200 as a Booster only for this type of setup. If you decide to do so, please keep this information in mind: The DCS100/200 configuration is stored in memory that uses a CR2032 battery. Over time the battery can get weak and the DCS100/200 will loose its ability to store its configuration. When this happens, the DCS100/200 will sound 7 beeps at power up. It will also revert back to its factory settings and once again become a Command Station. Since LocoNet ...
The green CONFIG Indicator shows the primary operating mode of the DCS100. This indicator should be steady green blinking off briefly once every 4 seconds. This indicates that the setting for DCS100 Option Switch 05 is set up correctly. If you see 8 blinks every 4 seconds then we recommend that you change the DCS100 Option Switch 05 to closed. The DCS100 will operate correctly in either case. The CONFIG Indicator will be mainly off when DCS100 option switch 01 is incorrectly set to closed. In this case you must change option switch 01 to thrown for correct operation.
When you hear 7 beeps when power is applied to your DCS100, you need to replace the CMOS battery. The DCS100 will continue to operate, even if this battery is not present, but all your memory settings and option switch settings will not be remembered when the DCS100 is powered down. To replace the CMOS battery without losing any memory settings: 1. Remove the DCS100 input power & disconnect all DCS100 leads. 2. Open the DCS100 case: a. Remove the two screws on the top and bottom of each side of the case. b. Slide the gray front panel off ...
Q: I have the original DCS100 with the old style non-removable wire connectors. What would I gain with a firmware upgrade? A: Early DCS100s that do not access Functions 9 - 12. If you have a DCS100 that you would like to have updated, please send it to the Digitrax Repair Department for updating. This update is a chip change only and the original style connectors will not be changed to the new style connectors. The circuit boards used for the two different connectors are completely different and are not interchangeable. The DCS100 must be sent to us for this ...
The MODE and SCALE switches are used to configure the DCS100 for your railroad. The 3 MODE switch settings are: RUN is for normal operations. OP is used to customize the DCS100 by changing its option switch settings. SLEEP is used to shutdown the system and all throttles that are plugged in to the system. SCALE Switch (O/G HO N) This switch sets the maximum track voltage limit. 1. Set the DCS100's SCALE switch to the scale you are running (N, HO, O\G). Use the lowest setting (N, HO, or O/G) that will run your layout. 2. Set the MODE switch ...
Regulated power supply delivers more power with less heat for more efficient booster operation. Operates up to 4 Five amp boosters. Scale selectable for use with N, HO or large scale. DC Ammeter. On/Off Switch. Integral cooling fan. Design coordinated for use with Digitrax products. One "Y" Cable (P/N YC52) Included for convenience with dual 5 amp protected outputs All secondary devices must be properly fused on their power input leads for their rated capacity. For example if you intend to use the PS2012 to drive a 5 and an 8 amp booster, you must input fuse these devices for ...
The actual track voltage supplied by the DCS100 can be adjusted. To do this, you must open the DCS100 case (this will not void your warranty). 1. Remove the DCS100 input power & disconnect all DCS100 leads. 2. Remove the two screws on the top and bottom of each side of the case. 3. Slide the gray front panel off the DCS100. 4. Be careful to avoid disturbing components other than the ones described below. 5. Locate the small yellow trimmer potentiometer behind the LocoNet B Jack and Scale Switch. 6. Use a small screwdriver to turn the potentiometer clockwise ...
Can I convert my DCS100 to a booster. I cannot find the switches in the instructions to accomplish this. Is it too old?. Can I return it for repair to accomplish converting it to a booster? The DCS100 is already a booster combined with a command station, but it can be converted to act as an expansion booster by using option switch 2 (OpSw02).
The two "POWER IN" terminals on all Digitrax boosters & command stations are the power input connections. Digitrax recommends the PS514 to power the DC200 and DB150. Set the voltage setting on the PS514 to 16.8v or 19v. The PS2012 can also be used to power the DCS100 and DB150. The "Y" cable provided with the PS2012 has an embedded 5 amp current protection. The PS2012 can also be used to power the DCS200. The "Y" cable is not suitable for use with the DCS200 since it has an 8 amp. output. When powering your layout, make sure that all polarities and ...
The NET indicator is a red LED that displays information about what the DCS100 sees on LocoNet. When your layout is wired correctly and LocoNet is operating properly, the NET indicator will be on and it will flicker off any time a good LocoNet message is detected by the DCS100. The table below explains the patterns you will see for this indicator.
The DCS100 automatically shuts down when the heat sink temperature rises to around 45 to 50 degrees Celsius and the OFF LINE indicator will glow red. The DCS100 automatically resumes operation when the heat sink cools down to approximately 40 degrees Celsius. The OFF LINE indicator will also be lit when there is no track status. This is normal and you should not be alarmed.
This list is the same for DCS100 & DCS200 Command Stations.* NOTE: Option Switches 36, 37, 38 & 39 have special instructions.
The TRACK STATUS indicator shows that there is voltage on RAIL A & RAIL B terminals. The color indicates the type of signal: If it is orange the track is getting DCC signals with no analog zero stretching. If the color is green or red then a stretched zero signal is being used to operate a conventional locomotive. When zero stretching is present, the DCC decoder equipped locomotives will read their digital commands normally and perform as commanded. If the Track Status LED is not lit there is no voltage on the track, the track power to the DCS100 may ...
The DCS100 uses several beeps and clicks that can be used as diagnostic tools that help you debug a number of conditions.
Q: I recently split my layout in half, with a DB150 acting as a booster powering one side and a DCS100 powering the other. I'm trying to reconnect the bus feeders to the rails, which all worked properly before the split. Now when I reconnect the feeders there is no short indication, BUT when a loco goes over the insulated gap between the two sections, a short occurs. A: This is a common issue when the first booster is added to a DCS100/DCS200 command station. MOST DCS100/DCS200 command stations come from the factory set with Rail A & Rail B connections that are the opposite ...
You can use your DT400 series throttle with a DCS100 or DCS200 to set up routes that are triggered by operating a single turnout address to make it either c (closed) or t (thrown). Setting up and operating routes is similar to consisting locomotives because you can cause more than one unit to operate based on a single command sent to the system. We call the turnout address that other turnout addresses are “consisted” to, the TOP address. To operate a route, use Sw (Switch) mode to select the TOP turnout address in the route and move it to either closed or ...
A slot is a memory location in the command station that holds an active decoder address. The number of slots is the number of locomotives that the command station can support in operation at a time. When the available slots are filled with decoder addresses, trying to select another locomotive address to run generates the "slot=max" error code. When all the slots are full you can't select another address until one is released from the system. See Clearing your Command Station's Mobile Decoder Slots below for how to prevent this from happening.The DCS100 Command Station/Booster that is included with Super Chief Xtra and other ...
Q: I connect my DT400 to my DCS100 and it works fine, but when I add a DB150 working as a booster the DT400 stops working. What is wrong? A: A number of things may cause this, so you can use the diagnostic features of the DT400 to solve this problem. Experience has proven that the most common LocoNet problem is related to pins 3 and 4. By following this diagnostic procedure, you can narrow down to the source of the problem. Starting with DT400 without a battery [The throttle has no battery for this test to assure it executes ...
The Super Chief can be used to operate routes. A Route is a group of turnouts and their specified positions that will be triggered by the activation of a single "TOP" switch address to a specified position. The DCS100 Super Chief supports up to 32 routes. Each route consists of a list that contains a TOP turnout address and its position (c or t) and up to 7 other turnout addresses and their positions. Routes are stored in the DCS100's memory and can be operated by any throttle in the system that can send switch commands. Each of these 32 ...
The 5 Amp DCS100 and the 8 Amp DCS200 share the same front panel layout. There is a variety of indicators, switches and connectors: Power Input The two POWER IN terminals on all Digitrax boosters & command stations are the power input connections. Power On Indicator This green LED indicates that the power to the DCS100 is on. Ground Terminal The terminal marked ground provides electrical safety features and an RF ground reference for minimum radiated noise. This should be the ONLY point of any DCS100 installation that is connected to the AC safety ground pin provided on most 3 ...
When using a DCS100 or DCS200 to setup routes within the Command Station in conjunction with DS64 Stationary Decoders, the DS64 needs to be connected to Track Power. The DCS100/200 does not send internal route messages via LocoNet. DCS100/200s only send Routes as a series of switch commands out to the Track in DCC format. The DSC100/200 were designed in 1996 and had no requirement to echo these same switch commands out via LocoNet. Additionally, DS64 Stationary Decoders are designed to allow up to 8 Routes to be programmed internally into them. Please refer to the DS64 manual and other ...
Does your throttle say slot=max ?This means that the system's capacity to handle operating locos is full. The DCS100 can run up to 22 or 120 addresses at the same time. If you have the slot=max message, be sure that all locos that are not running are released from throttles or set DCS100 OpSw 44 to closed to increase the number of address slots available to 120. The DCS100 command station that comes with all Genesis, Empire Builder and Chief series starter sets are set with a factory default of 22 slots. So, once you begin to operate significantly more locos, you may need to ...
I would like to know what the output voltage of PROG A & PROG B terminals should be on my DCS100 Command Station. Under normal circumstances, there will be no voltage present across PROG A & PROG B. When the DCS100 is actually programming a decoder, there will be brief bursts of voltage up to 12 Volts.
DS64 is set up by setting Option Switches (OpSw)This is how to set option switches on the DS64:1. Begin with your DS64 powered up. Turnouts can be either connected or not.2. On the DS64 press and hold the OPS button down for about 3 seconds until the red OPS LED and green ID LED begin to blink alternately. This indicates that the DS64 is ready to change the option switches.3. Using your DCC throttle, select the Switch Address that corresponds to the OpSw number and send the Closed or Thrown command corresponding to the setting you have chosen. Refer to ...
The master volume control CV is CV58, its values range from 0 to 15. The factory default value for this is 09.Digitrax SFX decoders have a factory default value of 09 set for CV58. This works well for 32 ohm speakers.The decoder will reset to this value whenever you do a decoder reset of CV8=8. Digitrax SFX decoders built for use with 8 ohm speakers should have this value changed to 4 or 5 for best operation value of 4 or 5, since the decoder may not supply enough current at high volume/drive levels.Your results may also depend upon track voltage present. Kato USA says ...
Is it possible to connect my BDL168 across two power districts (Boosters). I envisage using zone 1 & 2, with detection sections 1-8 one one booster (DCS100), with zones 3 & 4, with detection sections 9-16 on another booster (DB150). Will this work? Please refer to the chart below: Note that Pins 1 & A, 6 & F, 13 & P, and 18 & V are identified as "Connection to Booster for Zone *. Each Zone can support up to four detection sections. So, for your application, the DCS100 would be connected to Pins 1 & A and 6 & ...
Follow these simple instructions to determine the best location/s on your layout for installing your UR panels for the best possible infrared or radio reception. With LocoNet, you can use Infrared, Duplex Radio and Simplex radio individually or in any combination on your layout.You'll need to be able to observe whether your command station is receiving commands from the UR panels when you are installing infrared or radio receivers and transceivers. Your Digitrax command station makes it easy to determine when the system is receiving a signal and when it is not. You can observe the NET LED and the Track Status Indicator or your ...
If your throttle says "slot=max", this means that the Super Empire Builder's capacity to handle operating locos is full. The DB150 can run up to 22 addresses at the same time. If you have the "slot=max" message, be sure that all locos that are not running have been released from throttles. This will free up room inside the DB150 for other locos to run. A DCS100 command station can run up to 120 locos so, if you are having this problem often, you should consider adding a DCS100 to your LocoNet system. To Release Locomotives 1. Use the throttle to ...
Q: I have a Digitrax Chief system. I wired the programming track as per the manual, using PROGA and PROGB outputs on the DCS100. I turned on the system and checked the track voltage with a Tony Trains RRamp meter, the mainline read 14.2 volts. The programing track did not read anything. I then checked the two wires coming from the DCS100 and they did not have any readable signal. A: The programing track connected to PROG A and PROG B will NEVER have track power on except the very instant the program message is sent. So, you would not ...
When DCC locos enter a brake section with braking on, they will receive braking commands from the command station instead of normal DCC operating commands. DCC locos in this braking section will come to a stop. When you throw the switch to allow normal DCC commands, the DCC locos will resume normal operation. Once the DCC loco has left the brake section under normal DCC power, simply return the switch to the break position so that the next DCC loco will stop in the section. This is useful if you want to have trains stop at stations around the layout ...
Why do my trains start moving at 25% throttle?You may need to adjust some CV valuesCheck the value of CV02, start voltage; the default setting is 0 (zero). You may need to adjust this value.Check the value of CV03, acceleration rate; the default setting is also 0. It is possible that the locomotive has been set for a slow acceleration rate.You can also adjust how each locomotive responds to throttle inputs by programming loadable speed tables or 3 step speed tables.If you decide to reset the decoder to factory default values , set CV08 to a value of 08 to reset the decoder back ...
Q: I read in the February 2008 "Scale Rails" on page 11 that I need to add some "High Frequency Filter" gizmos on my layout to make my trains run properly. I have been using Digitrax equipment for 12 years, do I need to make these changes? A: We do not feel that this is necessary. With modern, well designed decoders, almost any combination of transmission-line ringing and other mismatch effects described in this article are completely filtered and ignored by the decoder. This is a superior solution rather than trying to design filters for unpredictable limiting cases of wiring ...
The DT400 can control Functions 1 - 12.Note: DT400 can access F0-F12 when used with the DCS50 Zephyr or DCS100 Super Chief command station. DT400 can only access F0-F8 when used with a DB150 Super Empire Builder command station.To enter Fn (function) mode:1. Determine which throttle you want to control functions on and make it the active throttle by single clicking the throttle knob or by turning the throttle knob a couple of clicks.2. DT400’s numeric keypad is always active in function mode during normal loco operations. When the mode indicator on your DT400 shows Fn, simply press any number ...
Braking sections are sections of track which will cause a DCC equipped locomotive to stop automatically. The simplest way to do this is to set up a track section where the power is turned off. This has two disadvantages. First, since there is no power, the locomotive lights will be off when the train is stopped in the section. Second, the lead loco in a consist stops as soon as it hits the dead section. Other locos in the consist will push the dead loco forward. In a long consist, you could get a situation where the last loco in ...
Before sending your Digitrax DS54 stationary decoder in for repair try these steps to see if you can “bring it back from the dead” and save a trip to the shop and possible repair charge.If you find you need to send in an item for repair, click here For Digitrax Repair Procedures and InformationAre there burn marks on the DS54 decoder?You'll need to send it in for repair!Understand CV programming with different throttleCV values shown are 00 or 000 for decimal and x00 for hex. Read your manual carefully to be sure you are using the appropriate values when programming ...
Notes on IPL updating DT402 Throttles to R2 DT402 throttles can be updated to R2 using any compatible PC connection, including the DCS240 and PR3. Always make sure you are using the latest version of DigiIPL to update your hardware. When updating DT402D throttles the RF24 module must also be updated to the latest RF24 firmware. After updating the DT402s to R2 it is recommended that you reset the throttle to factory default. If you encounter any issue updating your DT402 throttle, the IPL update process can be repeated to resolve any issues. Occasionally running the update twice or 3 ...
The DCS50 is set up at the factory to run right "out of the box", but the DCS50 does have several operational options that you can use to customize the perfomance of your railroad. It should be noted that: Most customers never have any need to change these options.Changing DCS50 Option Switches1. See the DCS50 Option Switch Table that follows to decide which option switches you want to change.2. Press the PROG key. The display shows the last decoder programming mode used by the DCS50.3. Press the SWITCH key. The display shows the last switch used by the DCS50 and ...
This document outlines the power requirements for Digitrax LocoNet accessories. To simplify wiring, Digitrax recommends providing individual power supplies for like accessories. For example a power supply or power buss which only powers the PM42s. A power supply or power buss used solely to power multiple DS64s. UR9x and UP5 panels can be daisy chained provided adequate current is provided to properly power all the panels. Through the use of individual power supplies, the chance of Ground Loops or sneak paths back to ground is minimized. Using individual power supplies will also make troubleshooting much easier. Many Digitrax LocoNet ...
The DT402 & DT400 can program and readback CVs with the DCS100 or DCS200 (Super Chief) or the DCS51 or DCS50 (Zephyr). You must use the programming track for this unless you are using Ops Mode with transponding installed to allow for Ops Mode readback. Infrared and simplex radio throttles must be plugged in to LocoNet to read back CVs & their values. Duplex radio throttles do not have to be plugged in for reading back CVs.Systems with a DB150 command station (Super Empire Builder) are not able to read back CV Values programmed into decoders. To read back CV values: 1. Place the decoder ...
I have a Zephyr control station and I would like to set up a Braking District as shown in your PDF sheet in the Basic DCC issue section; you show a DCS100 connecting through a modified LocoNet cable to a DBxxx booster -- can this same setup be used with a Zephyr system? No. The braking district described here uses Super Chief and a second booster to create a braking district. Super Chief is configured by toggling OpSw47 and connecting it to a second booster that is properly configured. Because Zephyr does not have an available OpSw47, and because there ...
Is it possible to use UP3 with a Super Chief system?Yes. Both have LocoNet in common, so the signals produced by the DCS100 Super Chief go though LocoNet to all devices that can connect to the LocoNet, including the UP3.
I have a DCS100. I do not understand why my DT400's speed increases (all the way up to 99) sometimes when I plug it in. Also, sometimes the Loco number (when selected when this is taking place) will increase too. There is no control enabled when this is taking place. If I plug in a DT100 it operates normally. One of the buttons on the DT400 may be stuck, leading to this behavior. Take a look at the control panel of the DT400 and you will probably see this stuck button since it will not be in a fully returned ...
Super Chief superseded Chief II.Super Chief IncludedA DT400 throttleA DCS100 Command Station BoosterA UP5 Universal PanelInstruction Sets
Chief was Digitrax third commercially produced starter set. It was manufactured from 1998 to 2000. It included:A DT100 throttleA DCS100 command Station Booster
Automated Routing with DS64 Routes are a way of operating a preset combination of turnouts to predefined positions using a single Switch command. Route tables hold the Switch Address and position information that make up the Route that operates when a single command is issued. The DCS100 Super Chief can store up to 32 individual routes that consist of a "Top" address and 7 additional turnout addresses and their positions. The DS64 has a route table that can hold up to 8 individual routes that consist of a "Top" address and 7 additional turnout addresses and their positions. Sensors ...
Q: Using Digitrax systems to program an MRC AD310 decoder is especially confusing because the MRC Command 2000 uses several "switches" and "levers" rather than standard CV numbers. A conversion chart for the 10 possible MRC engine addresses would be a wonderful help to us old-timers. A: The documentation available from the manufacturer of this decoder is incomplete. Many older decoders such as this one are not able to recognize all the digital packets in use by more modern DCC Systems. What we have learned is the MRC AD310 is: Programmable up to 127 (1~127) locomotive addresses Programmable for either 28 or ...
Programming On The Mainline: Operations Mode ProgrammingOperations Mode Programming [Ops Mode] lets you program CVs in DCC locomotives equipped with Extended Packet Format decoders while they are on the mainline. This is handy for situations where you want to make an adjustment to a specific locomotive while it is in service. There are also situations where mobile decoders from other manufacturers can only be programmed in this manner. A typical use for Ops mode programming would be to change the acceleration rate (CV03) or the deceleration rate (CV04) of your locomotives to simulate the weight and braking capability of the ...
I'm trying to install a DH123D decoder in a Life like P2K PA loco and make the mars light work. HELP! Because the DH123D is a two-function decoder (front headlight, rear headlight), it may not be the best decoder choice for this locomotive. In practice, some PA's had only one headlight, thus there would be no Mars light. The DH123D would be an appropriate choice for those locomotives. Typically, eastern railroads would just have one headlight; think Pennsy and Southern Railway. Western railroads, because of higher train speeds, often used warning lights such as the Mars Light or Pyle Gyra-Light; ...
We are a LARGE club layout. We have several reversing districts, 25 operators and run 30 trains at a time. We want computer control, turnout control, signaling. You name it, we've got it. What equipment do we need to run this layout?You probably need the Super Chief Xtra Set with additional throttles, boosters, mobile & stationary decoders & detectors.A typical HO layout of this size would need approximately 5 boosters & power supplies to provide enough power to run 30 engines. The DCS100 command station/booster will be one of these boosters so; you would need 4 additional DB150 series boosters. You will ...
Each DCC decoder that is installed in a locomotive is assigned a unique address. To select a locomotive and run it on either throttle, you must know the address assigned to the decoder. Digitrax decoders are set up at the factory with the “default” digital address of 03. This means that when you take a Digitrax decoder out of the package and install it in your loco, you can select address 03 on your throttle and run the decoder. The first Configuration Variable (CV) programmed by most DCC users is the decoder’s address since it is not very useful to ...
CVs are decoder memory locations that hold loco address, operational configuration and performance settings. Adjusting them to customize the performance of a specific locomotive is one of the main advantages of DCC over DC running. - Doug StuardThese are special storage locations or "pigeonholes" in your mobile decoders. By programming various CVs, you can control each decoder's performance characteristics. CVs store information like the decoder's short address, long address, start voltage, mid-point voltage, loadable speed tables and many more. Once you have programmed these characteristics, the decoders "remember" them until you change them again. Most manufacturers use a similar set ...
DT400 is designed to maintain a close similarity in function & feel with Digitrax DT300, DT200, & DT100 series throttles. This family resemblance makes it easy to add new throttles to your Digitrax Command Control System and be able to use them in ways similar to the existing throttles that you are already used to. DT400 can be used with any Digitrax LocoNet System or other LocoNet compatible DCC system. User friendly Multi-line Backlit LCD with easy to read icons and messages. Prompts in the display guide you every step of the way. To make operation easy and ...
CV # Use Decoder DefaultValue ValueRange CV01 Address All 01-9999 01-127 * CV02 Start Voltage All 001 0-255; higher is more voltage CV04 Acceleration Rate All 000 0 - 31 CV04 Deceleration Rate All 000 0 - 31 CV05 Maximum Voltage Gen4 - 0 (disabled) 1 - 255; lower is slower CV06 Midpoint Voltage All 0 (disabled) 1 - 255 CV07 Manufacturer's Version ID All Variable - CV08 Manufacturer's ID, Decoder Reset All FX3 129 08 to reset,09 reset leave speed tables CV13 DC Functions "On" FX, not on FX3 - See decoder documentation CV15 Decoder Lock FX3 000 See ...
Q: How do I program the PM42 Option Switches (OpSw) with a DT400 throttle? A: The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSws is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the DT400 series throttle with any Digitrax command system. 1) Connect the PM42 to a DCS50, DCS51, DB150, DCS100, or DCS200 with a standard LocoNet cable. 2) Connect the PM42 to an external power source; Digitrax ...
There are many different CVs that have been defined to control operating characteristics of your locomotives. Your decoder manual has a complete listing of CVs that are available with specific decoders, what they do and suggested values for each CV. Programming these CVs is simple:1. Be sure that only the locomotive you want to program is on the programming track.2. Press the PROG Key to enter programming mode. The DCS50 will display one of the programming modes available. Digitrax recommends the Paged Mode when you are using the programming track. As you press the PROG Key repeatedly, you will cycle ...
Q: I just purchased a used Digitrax set consisting of a DB150, UT2 and a PS515 for a very low price. What do I need to add to bring this up to current standards? A: Because of Digitrax LocoNet, it is easy to add the latest components to upgrade on older starter set. What you purchased was originally called a Genesis Starter Set. The PS515 did not come with it but it is the perfect power supply for the DB150. Your next step depends on what you want to do with your railroad. In this case, the components you have will be ...
Q: Can you have two command stations on the same layout? A: No. If you try and run with two command stations you will experience what we usually refer to as "shocking, horrifying results." Two command stations on a single layout is often a problem with modular layouts. You can disable the command station capability in Digitrax Command Station/Boosters so that you can use them as boosters only to add more power to your layout.For the DCS100 to disable command station mode:1. Set Op switch 2 to "c" 2. Set Op switch 5 to "t" 3. Set it to auto ...
Digitrax Series 3 Decoders include the following features and more: FX3 Function Outputs Supersonic motor drive for quiet operation Support for all DCC programming methods One-Step decoder factory CV reset Motor isolation protection White or Golden Yellow LEDs on decoders that come equipped with LEDs Operations mode read back capability for CV read back on the main line
I have a Zephyr and a DT400 throttle. My locos have chips of various manufacture. Is there a method, without dismantling the loco of reading which chip is fitted in it? Well, we can't speak for other manufacturers, but if you take a look at the Digitrax decoder index, you will note that many Digitrax decoders have a Manufacturer's ID of "129". This is found by reading the value of CV#8. Some other manufacturers also use Manufacturer's IDs, and you will need to consult their documentation for this information. Note: CV08 is also used to reset Digitrax Series 3 decoders ...
HELP!!!!!!!!If your Zephyr DCS50 display isn't showing you what you expect based on the manual, press the EXIT key to return to normal operating mode. Also make sure that the "Power" is on. Then try the throttle task again. If you think you might have made an inadvertent change to one of the factory settings in either the decoder or the command station, try resetting everything to the factory settings and try the task again. Please see the related articles (below).
Digitrax SoundFX Decoder Troubleshooting Guide This troubleshooting guide assumes that you are working with an operating Digitrax system that is able to run trains and that the locomotive you are troubleshooting is operational and has a Digitrax sound decoder and speaker installed correctly. If there is no sound, first make sure the decoder is not muted: Press the Function 8 (F8) key, and make sure F8 is OFF. Function 8 is used to toggle between sound active (F8 OFF) and mute (F8 ON). If there is no sound and the locomotive won’t move when the address is selected on your ...
Why does the DS64 generate multiple output pulses for a single command? I get between 2 and 5 pulses over a period of about 2 seconds. Option Switch 01 determines the type of turnouts that you can operate, static or pulse. The Factory default is for "Pulse". Option Switches 02, 03, 04, and 05 set the pulse length. OpSw 02 = Closed the pulse width is 200ms (milliseconds). OpSw 03 = Closed, the pulse width is 400ms. OpSw 04 = Closed, the pulse width is 800ms. OpSw 05 = Closed, the pulse width is 1600ms. All, or any combination of ...
PM74 Current Trip settings: The PM74 has the nominal trip current for all 4 channels configured by OPSW7 and OPSW8, in the following order; If OPSW7 is changed to Closed, then Trip current is 3Amps, and OPSW8 is ignored If OPSW8 is changed to Closed , then Trip current is 6Amps. If OPSW7 and 8 are both Thrown (factory reset default) the Trip current is default 4Amps. Note that the DCC channel current is typically time-varying, so the trip current is usually a peak above the average track currents detected. The continuous/combined current on any of the track plug/connectors must ...
Status Editing - a DCC decoder's status can be manually changed by a Digitrax command station at any time the decoder is selectable. Speed steps are the increments of motor voltage that a locomotive's mobile decoder produces. Most DCC decoders can operate in 14, 28 or 128 speed steps. In some cases, older decoders operate only in 14 steps. You also may find that it is better to adjust the number of speed steps used by a particular decoder. Digitrax uses status editing to change how the command station communicates with an individual decoder. Our systems power up with the ...
Q: If my layout is experiencing short because of a thrown switch, how can you reset the switch using DCC? Many Digitrax operators use the PM42 Power Manager, which provides protection to four power sub-districts. One segment of the PM42 is used to control track switch power, with the balance being used for train power. When the inevitable happens and a train runs into a thrown switch, resulting in a short, the PM42 shuts down the track power in that segment, while the track switch power is maintained, allowing you to throw the offending switch. Because the PM42 isolates only ...
The layout uses twenty-eight turnouts on the mainline and an additional eleven turnouts in the yard. Each turnout is powered by a Tortoise slow motion turnout motor. Each of the twenty-eight mainline turnouts has three dwarf signals associated with it. The aspects of the signals are shown below. The indications of the signals are: Green = Proceed Yellow = Proceed with caution Red = Stop Each signal has one head with two LEDs. There are also thirty-eight mainline block signals (red/green) that are controlled by heavy duty single pole double throw relays. This makes a total of 122 signals. Since ...
What is the difference between programing on the layout using Track A and B and using a dedicated programing track using Pgm A & B. Is there a difference in voltage, packets, protocol between the two? Programming Track Broadcast programming, also called service mode programming, uses a programming track. The programming track is electrically separate from the rest of the railroad, and is connected to the "PROG A" and "PROG B" terminals of your DCS100/200 or Zephyr (Xtra) command station.One major advantage to a programming track is that many systems can read-back the Configuration Variables (CV's) that are in ...
Whoa!!!!!Each locomotive on your railroad has a mobile decoder which receives the command control signals from the command station and operates the locomotive motor accordingly. The performance of mobile decoders can be adjusted by changing the Configuration Variables (CV's) of the decoder. You can improve the speed performance of a locomotive by adjusting its start speed (CV02, V-Start), its mid-range speed (CV06, V-Mid) and its top speed (CV05 - V-Max). You can also adjust the acceleration (CV03) and the deceleration (CV04).If the deceleration CV value you set for a particular loco is very large, this can make it look like ...
The actual track voltage supplied by the DB150 can be adjusted. To do this, you must open the DB150 case (this will not void your warranty). 1. Open the DB150 case. Remove the black screws on the top and bottom of the case and slide the gray front panel off. Be careful to avoid disturbing components other than the ones described below. 2. Locate the small yellow trimmer potentiometer behind the LocoNet B Jack and Scale Switch. 3. Use a small screwdriver to turn the potentiometer clockwise to increase the scale voltage setting. Turn it counter clockwise to decrease the ...
LNWI Advanced Options Status LEDs: The LNWI has two status LEDS Green ID indicator and a Red OPS indicator. The state of these indicators can be interpreted to provide status information and also some useful diagnostic insights. Table 1: Status LEDs LED Status Indicates Green ID indicator mostly lit, winking OFF every 3 seconds LNWI is powered and connected to LocoNet Green ID indicator mostly off, blinking ON every 3 seconds LNWI is powered and LocoNet is not connected or sleeping Green ID indicator winks OFF LNWI received a good LocoNet Message Red OPS indicator blinks ON LNWI received a ...
To program Bachmann's E-Z Command® Decoder-Equipped DCC Turnouts follow these steps: 1. Connect the turnout (or wye or crossover) to a powered section of track (Rail A & B)2. Verify Track Power is on.3. Press and hold the programming button of the E-Z Command® turnout/wye/crossover until switch toggles twice (release programming button). The turnout is now in programming mode. 5. Press Switch button on the Throttle. 6. Select the desired address on the Throttle (1-100 for this device). 7. Press OPTN button if using a DT40x or DT500 series Throttle, the CV-WR key then the EXIT key on a DCS50/51 ...
Q: Can I assume that any of the 3 powering options for the DS64 are acceptable for OpSw changes? A: Yes you can power the DS64 using any of the 3 options. The DS64 is strictly looking for power, and doesn't need the DCC signal from the track to set op-switches. Q: If I have only 3 turnouts on a DS64, to complete the 4 point programming I have been inputting a bogus turnout number. Is that correct? A: Yes, that is correct. Q: When setting OpSw 1, do I have to be connected to track power or can I power ...
This example is a small yard with a crossing signal at its entrance. We will use independent turnout addresses to demonstrate the flexibility that the DS64 offers. Here, route (track) 2 3 and 4 will activate the blinking light when set and the deactivation is done by resetting to route 1, the main line. The advantage of this setup is that you can easily do operating RR Crossing lights without the need for additional equipment for block detection. The turnout output utilized for the RR crossing operation is simply integrated into the route setup. In addition to the route ...
If Zephyr DCS50/DCS51’s display shows FuLL this means that it has reached the limit of 10 (20 for the Zephyr Xtra) locomotive addresses that it can manage at one time. If you want to select additional addresses, you will need to release one or more loco addresses before you will be able to select other locomotives to run.The DCS50/DCS51 runs a “purging” routine that helps eliminate addresses that have not been used for a period of time to make slots available for running other addresses.If you see this "FuLL" message while you are operating, you can release locos that you ...
There is a numeric keypad on the DT402/DT400 throttle. The numeric keys on the keypad are primarily related to the throttle mode shown in the LCD’s mode indicator area, but can be used for numeric entry and function control in other modes. For example, when the command station is in the Function Mode Fn, the numeric keys are used for function control. When the command station is in the Locomotive Mode,Lo, the numeric keys are used to enter loco addresses. When the command station is in the Switch Mode is Sw, the numeric keys are used to enter switch addresses.In ...
The tuneable trip current (TTC) adjustment allows you to set the current at which the reversing section reverses when the train crosses the gap into the section. This allows you to improve the operation of your reversing sections.The tuneable trip current is adjustable from .25 amps to 8 amps. Turning the TTC screw clockwise increases the current trip point and turning the TTC screw counterclockwise decreases the current trip point. The total adjustment is approximately one half revolution of the TTC adjustment screw. The TTC adjustment is made using a full load on the reversing track--the total number of locomotives/cars ...
There are 1024 different CVs that have been defined to handle many characteristics you might want to use for your locomotives. Your decoder manual has a complete listing of CVs that are available in specific decoders, what they do and suggested values for each CV. 1. Place the decoder equipped locomotive you want to program on the programming track. If you are using operations mode programming, the loco you want to program can be anywhere on the layout but it must have a decoder that is capable of ops mode programming installed. 2. Enter Program Mode by pressing the PROG ...
Zephyr Xtra (DCS51) and Zephyr (DCS50) systems can program Soundtraxx Tsunami decoders using Blast Mode Programming on the Mainline. Blast Mode Programming will program EVERYTHING sitting on the main line track so, you MUST remove everything from the track that you are not programming or use an isolated piece of track connected to Rail A & B. NOTE: Track power must be ON during Blast Mode Programming. Blast Mode programming will work with all sound decoders not just Tsunami. You will not be able to read back CVs using Blast Mode Programming. To use Blast Mode Programming with Zephyr, close ...
The Mode Switch: The Mode Switch next to the Green LED is used to toggle back and forth between MS-100 mode and PR2 Programmer Mode. The Green LED will wink once per second if in the MS-100 Mode or toggle every second when in the PR2 sound programming mode. The Loconet Termination Switch: The switch next to the error LED is used only in MS-100 mode to activate the Loconet current source termination feature. This switch is active ONLY when a command station is NOT connected to the Loconet and the red LED is solid on indicating there is no ...
In addition to the locomotive address, there are different Configuration Variables (CV's) that have been defined to handle many characteristics you might want to use for your locomotives. These include operational characteristics such as acceleration, headlight functions and others. The manual for each decoder type has a complete listing of CVs that are available in specific decoders, what they do and the suggested values for each CV. Simpler decoders have few CVs while advanced decoders may have many different CVs 1. Place the decoder equipped locomotive you want to program on the programming track If you are using operations mode ...
The DS64 is a powerful stationary decoder that can be used to control different devices on your railroad. It can be used on both command control and analog model railroads. The DS64 is configured by the settings of different Option Switches (OpSw's), listed below: OpSw01 - Solenoid or slow motion devices OpSw02 - Pulse Timeout, 200ms OpSw03 - Pulse Timeout, 400ms OpSw04 - Pulse Timeout, 800ms OpSw05 - Pulse Timeout, 1600ms OpSw06 - Output Auto Power Up OpSw07 - Factory-default Reset OpSw08 - Regular/Extended Startup Delay OPSw09 - Timeout Option OpSw10 - Throttle/Computer Option OpSw12 - Sensor Input Option OpSw13 ...
How To Run a Route with DS64:1. Select the Switch Address that corresponds to the Top Address of the route you want to run.2. Issue a Closed or Thrown command depending on which you set up in the route table.Note that if you are using an actual switch address as your top address and you send the opposite closed or thrown command from that set up in the route; you will operate that switch address only and not the route.For example: If you set up Switch Address 50 as your Top Address by sending a Thrown command, you’ll need to ...
Programming is the process of setting the configuration variables (CVs) in your decoder to the appropriate values that will make the locomotive perform the way you want it to. The first CVs that most people change are those that set the locomotive decoder's address. The mobile decoder in your locomotive usually comes pre-porgrammed to a factory default address of "03". Once you add a second locomotive, you will want to change the this new locomotive to another address. Not doing so will result in both locomotives operating at the same time when you send commands to address 03.Likewise, there are a ...
DCS240 FAQ I’m getting a “StealZap” or message on my DT402 rev 2 throttle. What is this? This is a feature that helps prevent having the same address selected on multiple throttles and creating unexpected operations. When you steal you are truly stealing control of the locomotive instead of sharing it as was the case before the DCS240 and DT402 R2 firmware were released. When using a DT402 R2 throttle with an Advanced Command Station featuring expanded slots, each throttle ID is associated with the Loco Addresses it has selected. When you select a Loco that is selected on ...
The Kelana Jaya Rail Line model is a DCC intense layout, using many Digitrax command control components to achieve the goal of training operators of the actual rail line. The railroad was built in the 1990's and many of the Digitrax devices used for the Kelana Jaya Rail Line model have been superseded with improved units. Components used for the Kelana Jaya layout: 28 Mainline turnouts 11 Yard turnouts 39 Tortoise switch machines 84 Dwarf signals (yellow/green, red/green, red/yellow) 38 Mainline block signals 38 Heavy duty SPDT switch relays Digitrax Components Used for the Kelana Jaya layout: 1 DCS 100 ...
The following CV settings have been found to give great performance from the Trix Mikado. These settings were discovered by Norm Stenzel after much trial and error. Once the loco was set with the following CV values this locomotive operated very nicely with the sound synchronized to its movement. CV 2 = 4 Default Value = 4 START VOLTAGECV 3 = 0 Default Value = 8 ACCELERATIONCV 4 = 0 Default Value = 6 DECELERATIONCV 5 = 35 Default Value = 64 MAX VOLTAGECV 6 = 20 Default Value = 22 MID POINT VOLTAGECV 29 = 6 Default Value = 4 CONFIGURATION ...
DT402 R2 Release Notes Access to Expanded Slots Updating the DT402 to R2 gives the throttle access to expanded slots in the DCS240 Advanced Command Station. Access to these expanded slots are only available when IR and Radio(RF1) options are set to OFF in your throttle. This means that throttles working in IR mode or Simplex Radio will not have access to the expanded slots. Simplex Radio throttles(DT402R) will have access expanded slots if radio(RF1) is set to off and the throttle is plugged in. It is recommended that throttles be factory reset after upgrading the firmware to R2. By ...
Duplex Radio Throttle do not need to be plugged in to LocoNet to Program Decoders. Simplex Radio & Infrared throttles must be plugged in to LocoNet to program CVs on the programming track. Ops Mode Programming can be done without plugging radio throttles in to LocoNet. IR throttles must be plugged in for Ops Mode Programming. 1. Be sure that only the loco you want to program is on the programming track. If you are using operations mode programming, the loco you want to program can be anywhere on the layout but it must have a decoder that is ...
Overview: Broadway Limited has issued a new line of H0-Scale locomotives called "Blueline". These locomotives are equipped with sound decoders that can be operated in a conventional Direct Current environment. They also are fitted with an 8-pin DCC Medium plug to allow for conversion to a DCC operating environment. Among other decoders, Broadway Limited recommends using our DN143IP mobile decoder for this purpose. Converting these locomotives is simple, but programming a 4 digit address can be a challenge. BLI has a support page which indicates that changing the locomotive address and other CV's can be done in OPS Mode (also ...
Decoder Lock lets you use more than one decoder in a locomotive and be able to program their CVs separately. This is a manufacturer specific CV. The instructions provided here work for Digitrax decoders. If you are using decoders from another manufacturer, please consult your decoder instructions for how this feature works with the decoder you have installed. For example, if you use a mobile decoder and a sound decoder together in your locomotive, you can use the same mobile decoder address during operation and when programming you can unlock only the one you want to program. Since all decoders with the ...
This article stops in a strange place?? We need to find the rest of it and split it up into meaningful chunks. Also needs meta stuff Troubleshooting in General:Regardless of the guides, manuals, tips, suggestions, experts or whatever, troubleshooting can occasionally degenerate into a vast chasm of darkness and confusion. It would be impossible to cover all the areas that have, can or may cause problems. This is a general guide to identifying and resolving problems with Digitrax Complete Train Control. Keep Good Records:Although it may seem to be a pain while setting up your Digitrax system, keeping layout records ...
Zephyr Xtra Super Empire Builder Xtra Super Chief Xtra Command Station DCS51 DB150 DCS100 Current Rating 3 Amps 5 Amps 5 Amps or 8 Amps Throttle DCS51 DT402 DT402 Throttle Controls Single Knob, Direction Switch Dual click encoder throttles Dual click encoder throttles Function Control F0-F29 F0-F29 F0-F29 Keypad Full Numeric Keypad Full Numeric Keypad Full Numeric Keypad Display Large LED Multi-line Backlit LCD Multi-line Backlit LCD Throttle Capacity 20 22 120 Loco Capacity 20 22 120 Loco Address Range 00-9000+ 00-9000+ 00-9000+ Stationary Address Range 01-999 00-999 00-999 Turnout Position Reporting Yes, last command sent Yes, last ...
The PS615 is the Digitrax recommended power supply for the DCS240 in 5 amp mode. For operations at 8 amps the PS2012 is the recommended power supply. When using the PS2012 special wiring considerations need to be used when powering both the DCS240 and legacy boosters from the same PS2012. Leagacy boosters are defined as the DCS100, DCS200, DB150, DB200 or DB100. Please see the separate article “Powering your DCS240 with a PS2012” and the additional notes below. The DCS240 may be powered either using the barrel plug connector or the screw terminals labeled “+” and “- “. The barrel ...
Option switches are used to change the operation of the DB150. Option Switch # Effect on system when Option Switch “c” closed Default OpSw 02 Booster Only override t OpSw 03 DB150’s booster is auto reversing t OpSw 05 Default closed for command station –DO NOT CHANGE- c OpSw 13 Loco purge time extended from 200 seconds to 600 seconds t OpSw 14 Loco purging is disabled t OpSw 15 Purging will force loco to Stop or 0 speed t OpSw 17 Automatic advanced decoder assisted [FX] consists are disabled c OpSw 18 Extend the DB150 booster short circuit ...
The DB200+ is the 8 amp booster. It has NO command station capability. This booster was designed for adding power to layouts that run lots of locos and for large-scale layouts where power requirements are heavy.DB200+ Control PanelNOTE: DB200+ front panel graphics may vary from those shown here. Internally the booster is the same. These instructions are written for both versions of graphics as well as the DB200+ OPTO optoisolated version of the booster. About the Green Jumper WireEvery DB200+ is shipped with a green jumper wire on the front panel Booster Terminal Plug connecting Synch & Ground or ‘Config ...
OpSw Setup Enter OpSw mode by pressing the OpSw button. The OPS and ID light will flash alternating RED and GREEN. Use your throttle in SWITCH mode to set switches to thrown or closed to match your desired OpSw setting. There are currently no published OpSws for the BXPA1. If you erroneously set an OpSw, the BXPA1 can be factory reset by setting OpSw40 = Closed Trip Speed Pot The Trip Speed Pot can be adjusted to set the speed at which auto reversing and power management is resolved. Turning the pot clockwise will make the speed slower and turning ...
We recommend testing your new SE8C prior to installation on your layout. The following testing procedures will help familiarize you with the general operation of the SE8C. Track power needs to be ON, a working LocoNet connection and a throttle or PC running DCC control software. Pre-Installation Set-Up 1. Solder one wire from a 12V AC or 15V DC power supply to Pin 3 and the second wire from the power supply to the Pin C on the 44-Pin edge connector; this powers the SE8C. Digitrax manufactures the PS14, which is appropriate for this installation. Multiple SE8Cs can be powered ...
Digitrax Query Mode: The new generation of Digitrax Advanced Command Stations and other new products from ~October 2016 onwards include some convenient new self-diagnostic and external diagnostic capabilities and methods, to help keep LocoNet systems and devices healthy and working optimally, without requiring additional tools. The DCS240 and DCS210 Advanced Command Stations include “Query Mode” diagnostic information that can be interrogated or read-out using enhanced capabilities of DT500 throttles. Advanced Command Station Query information is grouped into six broad groups of data/diagnostic information displayable by a DT500/DT500D: “Lnt”: LocoNet Device Type/product info “ELE”: Device Electrical information, voltages/currents, etc. “Lnt”: LocoNet ...
The MODE key is used to move from one operational mode to another on the DT300 throttle and to dispatch selected addresses or consists to make them available for use by other throttles in the system. Lo (Loco) mode is the DT300’s default mode since most of the time you are running locomotives.Press the MODE key to cycle from Lo (Loco) mode to Sw (Switch) mode to Mu (Multi Unit) mode and back to Lo, and so on.The current operation mode will show in the middle of the bottom row of the LCD display.Dispatch: To Dispatch or offer a locomotive ...
Zephyr Xtra Super Empire Builder Xtra Super Chief Xtra Command Station DCS51 DB150 DCS100 Current Rating 3.0 Amps 5 Amps 5 Amps or 8 Amps Throttle DCS51 DT402 DT402 Throttle Controls Single Knob, Direction Switch Dual click encoder throttles Dual click encoder throttles Function Control F0-F28 F0-F28 F0-F28 Keypad Full Numeric Keypad Full Numeric Keypad Full Numeric Keypad Display Large LED Multi-line Backlit LCD Multi-line Backlit LCD Throttle Capacity 20 22 120 Loco Capacity 20 22 120 Loco Address Range 00-9000+ 00-9000+ 00-9000+ Stationary Address Range 01-999 00-999 00-999 Turnout Position Reporting No Yes, last command sent Yes + actual ...
Digitrax series7 mobile decoders have many industry standard Configuration Variable (CV) numbers and values, as well as numerous Digitrax custom CV numbers and definitions or controls. The series7 CV values are a superset of older Digitrax FX3 series3 and series6 decoders, already covered in Digitrax Decoder Manual V2 on the Digitrax Web site. The “CV8 to 8 default” columns indicate current factory defined value after writing a value of 8 to CV8, using; Service mode programming track or Mainline Operations Mode Write to the active decoder address. An entry with value/xx indicates a xx number invokes the value before the ...