KB274 What Voltage on Prog A & Prog B?

I would like to know what the output voltage of PROG A & PROG B terminals should be on my DCS100 Command Station. Under normal circumstances, there will be no voltage present across PROG A & PROG B. When the DCS100 is actually programming a decoder, there will be brief bursts of voltage up to 12 Volts.

KB534 Short Circuit when adding a DB100 or DB150 booster to a DCS100 or DCS200 Command Station

Q:  I recently split my layout in half, with a DB150 acting as a booster powering one side and a DCS100 powering the other. I'm trying to reconnect the bus feeders to the rails, which all worked properly before the split. Now when I reconnect the feeders there is no short indication, BUT when a loco goes over the insulated gap between the two sections, a short occurs. A:  This is a common issue when the first booster is added to a DCS100/DCS200 command station. MOST DCS100/DCS200 command stations come from the factory set with Rail A & Rail B connections that are the opposite ...

KB281 Is it possible to use UP3 with a Super Chief system?

Is it possible to use UP3 with a Super Chief system?Yes. Both have LocoNet in common, so the signals produced by the DCS100 Super Chief go though LocoNet to all devices that can connect to the LocoNet, including the UP3.

KB415 DCS 100 & 200 Front panel

The 5 Amp DCS100 and the 8 Amp DCS200 share the same front panel layout. There is a variety of indicators, switches and connectors: Power Input The two POWER IN terminals on all Digitrax boosters & command stations are the power input connections. Power On Indicator This green LED indicates that the power to the DCS100 is on. Ground Terminal The terminal marked ground provides electrical safety features and an RF ground reference for minimum radiated noise. This should be the ONLY point of any DCS100 installation that is connected to the AC safety ground pin provided on most 3 ...

KB555 DCS100 Command Station/Booster Expanding Available Slots

A slot is a memory location in the command station that holds an active decoder address.  The number of slots is the number of locomotives that the command station can support in operation at a time. When the available slots are filled with decoder addresses, trying to select another locomotive address to run generates the "slot=max" error code.  When all the slots are full you can't select another address until one is released from the system. See Clearing your Command Station's Mobile Decoder Slots below for how to prevent this from happening.The DCS100 Command Station/Booster that is included with Super Chief Xtra and other ...

KB55 RR&Co Settings for BDL168 & BXP88 Operation

Railroad & Co. is a suite of computer programs for both digitally and conventionally controlled model railroads. The BDL168 needs to have several Option Switches changed for proper operation with Railroad & Co.'s Train Controller program. Our recommendations are based upon experience with earlier versions of the program: Suggested BDL168 Settings for Railroad & Co. (from European users): OpSw9 = Closed (No message sent if un-powered) OpSw36 = Closed (Ignore GPON) OpSw37 = Closed (Long delays for sensors) OpSw38 = Closed (Extra long delay for sensors) OpSw39 = Closed (Verbose mode enabled) OpSw43 = Closed (Filter for transponding disabled) OpSw45 ...

KB318 DCS100 - CMOS Battery Replacement

When you hear 7 beeps when power is applied to your DCS100, you need to replace the CMOS battery. The DCS100 will continue to operate, even if this battery is not present, but all your memory settings and option switch settings will not be remembered when the DCS100 is powered down. To replace the CMOS battery without losing any memory settings: 1. Remove the DCS100 input power & disconnect all DCS100 leads. 2. Open the DCS100 case:  a. Remove the two screws on the top and bottom of each side of the case. b. Slide the gray front panel off ...

KB321 DCS100 Audible Sounds

The DCS100 uses several beeps and clicks that can be used as diagnostic tools that help you debug a number of conditions.

KB322 DCS100 - Track Voltage Adjustment

The actual track voltage supplied by the DCS100 can be adjusted. To do this, you must open the DCS100 case (this will not void your warranty). 1. Remove the DCS100 input power & disconnect all DCS100 leads. 2. Remove the two screws on the top and bottom of each side of the case. 3. Slide the gray front panel off the DCS100. 4. Be careful to avoid disturbing components other than the ones described below. 5. Locate the small yellow trimmer potentiometer behind the LocoNet B Jack and Scale Switch. 6. Use a small screwdriver to turn the potentiometer clockwise ...

KB323 DCS100 - Mode Switch & Scale Switch

The MODE and SCALE switches are used to configure the DCS100 for your railroad. The 3 MODE switch settings are:  RUN is for normal operations. OP is used to customize the DCS100 by changing its option switch settings. SLEEP is used to shutdown the system and all throttles that are plugged in to the system. SCALE Switch (O/G HO N) This switch sets the maximum track voltage limit. 1. Set the DCS100's SCALE switch to the scale you are running (N, HO, O\G). Use the lowest setting (N, HO, or O/G) that will run your layout. 2. Set the MODE switch ...

KB324 DCS100 - Off Line Indicator

The DCS100 automatically shuts down when the heat sink temperature rises to around 45 to 50 degrees Celsius and the OFF LINE indicator will glow red. The DCS100 automatically resumes operation when the heat sink cools down to approximately 40 degrees Celsius. The OFF LINE indicator will also be lit when there is no track status. This is normal and you should not be alarmed.

KB325 DCS100 - Track Status Indicator

The TRACK STATUS indicator shows that there is voltage on RAIL A & RAIL B terminals. The color indicates the type of signal:  If it is orange the track is getting DCC signals with no analog zero stretching.  If the color is green or red then a stretched zero signal is being used to operate a conventional locomotive. When zero stretching is present, the DCC decoder equipped locomotives will read their digital commands normally and perform as commanded. If the Track Status LED is not lit there is no voltage on the track, the track power to the DCS100 may ...

KB326 DCS100 and DB150 - Power Supply

The two "POWER IN" terminals on all Digitrax boosters & command stations are the power input connections. Digitrax recommends the PS514 to power the DC200 and DB150.  Set the voltage setting on the PS514 to 16.8v or 19v.  The PS2012 can also be used to power the DCS100 and DB150.  The "Y" cable provided with the PS2012 has an embedded 5 amp current protection.  The PS2012 can also be used to power the DCS200.  The "Y" cable is not suitable for use with the DCS200 since it has an 8 amp. output. When powering your layout, make sure that all polarities and ...

KB455 Route Basics - DCS100 or DCS200

You can use your DT400 series throttle with a DCS100 or DCS200 to set up routes that are triggered by operating a single turnout address to make it either c (closed) or t (thrown). Setting up and operating routes is similar to consisting locomotives because you can cause more than one unit to operate based on a single command sent to the system. We call the turnout address that other turnout addresses are “consisted” to, the TOP address. To operate a route, use Sw (Switch) mode to select the TOP turnout address in the route and move it to either closed or ...

KB584 DCS100 - Firmware Update?

Q: I have the original DCS100 with the old style non-removable wire connectors. What would I gain with a firmware upgrade? A: Early DCS100s that do not access Functions 9 - 12. If you have a DCS100 that you would like to have updated, please send it to the Digitrax Repair Department for updating. This update is a chip change only and the original style connectors will not be changed to the new style connectors. The circuit boards used for the two different connectors are completely different and are not interchangeable. The DCS100 must be sent to us for this ...

KB458 DT402 & DT400 - Read Back CVs

The DT402 & DT400 can program and readback CVs with the DCS100 or DCS200 (Super Chief) or the DCS51 or DCS50 (Zephyr). You must use the programming track for this unless you are using Ops Mode with transponding installed to allow for Ops Mode readback.  Infrared and simplex radio throttles must be plugged in to LocoNet to read back CVs & their values.  Duplex radio throttles do not have to be plugged in for reading back CVs.Systems with a DB150 command station (Super Empire Builder) are not able to read back CV Values programmed into decoders. To read back CV values: 1. Place the decoder ...

KB461 DT400 & DT402 - Programming CVs other than address

In addition to the locomotive address, there are different Configuration Variables (CV's) that have been defined to handle many characteristics you might want to use for your locomotives. These include operational characteristics such as acceleration, headlight functions and others. The manual for each decoder type has a complete listing of CVs that are available in specific decoders, what they do and the suggested values for each CV. Simpler decoders have few CVs while advanced decoders may have many different CVs 1. Place the decoder equipped locomotive you want to program on the programming track If you are using operations mode ...

KB464 DT402 & DT400 - Programming Mobile Decoder Addresses

  Duplex Radio Throttle do not need to be plugged in to LocoNet to Program Decoders.  Simplex Radio & Infrared throttles must be plugged in to LocoNet to program CVs on the programming track. Ops Mode Programming can be done without plugging radio throttles in to LocoNet. IR throttles must be plugged in for Ops Mode Programming. 1. Be sure that only the loco you want to program is on the programming track. If you are using operations mode programming, the loco you want to program can be anywhere on the layout but it must have a decoder that is ...

KB595 Command Station Option Switches-Clear Slots and Factory Reset

Digitrax command stations have Option Switches that care used to customize their operation.  Command Station option switches should not be changed unless you fully understand what you are trying to accomplish.  Information on these Option Switches is included in each command station's manual.Be sure that you are changing the correct Command Station Option Switches as the unit can be crippled by closing the wrong switches.  NEVER CLOSE OPTION SWITCH #1!!Clearing your Command Station's Mobile Decoder SlotsMost command station problems are caused by filling up the command station's available slots by the following:1.  Operators failing to zero the speed of unused ...

KB327 Using the DS64 with internal DSC100 routes

When using a DCS100 or DCS200 to setup routes within the Command Station in conjunction with DS64 Stationary Decoders, the DS64 needs to be connected to Track Power. The DCS100/200 does not send internal route messages via LocoNet. DCS100/200s only send Routes as a series of switch commands out to the Track in DCC format.  The DSC100/200 were designed in 1996 and had no requirement to echo these same switch commands out via LocoNet.  Additionally, DS64 Stationary Decoders are designed to allow up to 8 Routes to be programmed internally into them. Please refer to the DS64 manual and other ...

KB616 HO layout and 8 amp boosters

I was planning on purchasing the Digitrax Super Chief Radio 5 amps but several members in the club told me to buy them Super Chief Radio 8 amp for my HO Layout.  They said you will need the power when you start expanding.Question:Is it ok to use the 8 amp version for my HO layout?Answer:Yes it is fine to use 8 amp Digitrax boosters on your HO layout.  The choice between 8 amp and 5 amp command station/boosters, it is a question of how much power your railroad is likely to consume on your railroad as it is built today.  ...

KB489 Programming DCS100 or DCS200 Option Switches with a DT300 throttle

Instructions below are for both DCS100 & DCS200 (DCS200 omitted in text for clarity).1. Refer to the DCS100 Option Switch Table to decide which option switches you want to change. Also note that there are special instructions for OpSw's 36, 37, 38, & 39. 2. Move the MODE toggle switch on the front of the DCS100 into the "OP" position . The LocoNet Railsync will go inactive & all other boosters plugged in to LocoNet, including the one that is built into the DCS100, will shut down. 3. Disconnect LocoNet from the DCS100 you are configuring. 4. Connect your DT300 ...

KB491 DCS100 and DCS200 Command Station Option Switches

This list is the same for DCS100 & DCS200 Command Stations.* NOTE: Option Switches 36, 37, 38 & 39 have special instructions.

KB492 Programming DCS100 and DCS200 Option Switches with a DT400 Series Throttle

Note:  These instructions are the same for DCS100 & DCS200 (DCS200 omitted for clarity).1. Refer to the DCS100 Option Switch Table to decide which option switches you want to change. Also note that there are special instructions for OpSw's 36, 37, 38, & 39. 2. Move the MODE toggle switch on the front of the DCS100 into the "OP" position . The LocoNet Railsync will go inactive & all other boosters plugged in to LocoNet, including the one that is built into the DCS100, will shut down. 3. Disconnect LocoNet from the DCS100 you are configuring. 4. Connect your DT400 ...

KB494 Upgrading Old Starter Set

Q:  I just purchased a used Digitrax set consisting of a DB150, UT2 and a PS515 for a very low price. What do I need to add to bring this up to current standards? A:  Because of Digitrax LocoNet, it is easy to add the latest components to upgrade on older starter set.  What you purchased was originally called a Genesis Starter Set.  The PS515 did not come with it but it is the perfect power supply for the DB150.   Your next step depends on what you want to do with your railroad.  In this case, the components you have will be ...

KB371 DCS100 - Converting to a booster.

Can I convert my DCS100 to a booster. I cannot find the switches in the instructions to accomplish this. Is it too old?. Can I return it for repair to accomplish converting it to a booster? The DCS100 is already a booster combined with a command station, but it can be converted to act as an expansion booster by using option switch 2 (OpSw02).

KB628 Performing factory decoder reset using Digitrax DCS100 & DT400 series throttle

Overview:To reset locomotive electronics to factory defaults the user must set CV08 to a value of 08. It is recommended that this procedure be performed on the dedicated service mode programming track using direct mode programming.* Note: This is the only programming procedure that we recommend using the programming track for. All other programming should be performed on the main track using Operations mode programming.Procedure:1. Place the DCC equipped locomotive on a dedicated service-mode programming track.* Note: The rails of this track should be connected to the PROG A & PROG B outputs on the DCS100 command station.2. Set the ...

KB505 Command Station Audible Beeps - DCS100, DCS200, DCS240, DB150

The DCS100, 200, 240 and DB150 use several beeps and clicks that can be used as diagnostic tools that will help you debug a number of error conditions.   DCS100/200 Audible Sounds 1 Beep           DCS100/200 has powered on successfully or has sent a programming command. 3 Beeps         A loco address has been "purged" due to non-use. This is informational only and is normal. 4 Beeps         Booster short circuit shutdown. Fault Alarm. 6 Beeps         Command station already present in system. When two command stations are operating on the same system, you may experience unexpected results. 7 Beeps         DCS100/200 CMOS battery low ...