KB384 Zephyr Xtra and Zephyr - Can I add a booster?

Q:  Can I add a booster to my Zephyr? A:  Yes. Since the DCS51 Zephyr Xtra and DCS50 Zephyr are equipped with LocoNet, adding additional boosters is easy; you simply divide your railroad up into power districts and add the boosters and their individual power supplies. These are connected together using LocoNet cables. Because the Zephyr Xtra is rated at 3 amps and the Zephyr is rated at 2.5 amps: most boosters have higher ratings, you may want to have the Zephyr control a smaller area that has fewer power consumers (locomotives, lighted passenger cars), such as a main line ...

KB264 DB150 Reset Instructions

There are times when it is necessary to reset the Super Empire Builder. Because this is a system reset, there are special instructions: There are different levels of system reset. OpSw 36: Clears all mobile decoder information, including locomotive consists. OpSw 38: Clears the locomotive roster (such as when you receive a "slot=max" error report). OpSw 39: Full reset, clears all internal memory states. The factory default setting for all DB150 option switches is t or "thrown" The Initial Procedure 1. Determine which DB150 option switch you want to change, 36, 38 or 39. 2. Move the Mode toggle switch on ...

KB265 DB150 Option Switch Setup

The DB150 has many customizable system operation options that you can set. The DB150's power up defaults are fine for most applications and the DB150 will run just fine right out of the box. These options are provided for those individuals who want more flexibility in setting up their operations. The factory default setting for all DB150 option switches is t or thrown except for 5, 17, 25, 33 and 34 which are closed ("c"). Changing DB150 Option Switches 1. Consult DB150 Option Switch Table to determine which DB150 option switches you want to change. 2. Move the right toggle switch on the ...

KB266 DB150 Option Switch Table

  Option switches are used to change the operation of the DB150. Option Switch # Effect on system when Option Switch “c” closed Default OpSw 02 Booster Only override t OpSw 03 DB150’s booster is auto reversing t OpSw 05 Default closed for command station –DO NOT CHANGE- c OpSw 13 Loco purge time extended from 200 seconds to 600 seconds t OpSw 14 Loco purging is disabled t OpSw 15 Purging will force loco to Stop or 0 speed t OpSw 17 Automatic advanced decoder assisted [FX] consists are disabled c OpSw 18 Extend the DB150 booster short circuit ...

KB267 Super Empire Builder- DB150 Beeps 5 Times

If the DB150 beeps 5 times and shuts down briefly and then comes back on again. It is probably being run too close to its pre-set current limit. To solve this problem, reduce the track current load by setting up additional power districts to provide more total power for the layout. In this case excess current consumption may clip or mutilate some outgoing packets to keep the track current within acceptable limits.

KB271 Zephyr as a Throttle

I have a Zephyr and a DB150. How can I wire the two together so that the Zephyr acts as throttle and the DB150 supplies power? At this this time I have only a single block. The easiest way to handle this situation is to divide the railroad up into two power districts. If one command station unit is more powerful than the other, then the area controlled by the weaker unit (in this case, the 2.5 Amp Zephyr) could simply be a single siding or engine terminal. The Zephyr would then become a booster, supplying power to this small ...

KB534 Short Circuit when adding a DB100 or DB150 booster to a DCS100 or DCS200 Command Station

Q:  I recently split my layout in half, with a DB150 acting as a booster powering one side and a DCS100 powering the other. I'm trying to reconnect the bus feeders to the rails, which all worked properly before the split. Now when I reconnect the feeders there is no short indication, BUT when a loco goes over the insulated gap between the two sections, a short occurs. A:  This is a common issue when the first booster is added to a DCS100/DCS200 command station. MOST DCS100/DCS200 command stations come from the factory set with Rail A & Rail B connections that are the opposite ...

KB326 DCS100 and DB150 - Power Supply

The two "POWER IN" terminals on all Digitrax boosters & command stations are the power input connections. Digitrax recommends the PS514 to power the DC200 and DB150.  Set the voltage setting on the PS514 to 16.8v or 19v.  The PS2012 can also be used to power the DCS100 and DB150.  The "Y" cable provided with the PS2012 has an embedded 5 amp current protection.  The PS2012 can also be used to power the DCS200.  The "Y" cable is not suitable for use with the DCS200 since it has an 8 amp. output. When powering your layout, make sure that all polarities and ...

KB458 DT402 & DT400 - Read Back CVs

The DT402 & DT400 can program and readback CVs with the DCS100 or DCS200 (Super Chief) or the DCS51 or DCS50 (Zephyr). You must use the programming track for this unless you are using Ops Mode with transponding installed to allow for Ops Mode readback.  Infrared and simplex radio throttles must be plugged in to LocoNet to read back CVs & their values.  Duplex radio throttles do not have to be plugged in for reading back CVs.Systems with a DB150 command station (Super Empire Builder) are not able to read back CV Values programmed into decoders. To read back CV values: 1. Place the decoder ...

KB461 DT400 & DT402 - Programming CVs other than address

In addition to the locomotive address, there are different Configuration Variables (CV's) that have been defined to handle many characteristics you might want to use for your locomotives. These include operational characteristics such as acceleration, headlight functions and others. The manual for each decoder type has a complete listing of CVs that are available in specific decoders, what they do and the suggested values for each CV. Simpler decoders have few CVs while advanced decoders may have many different CVs 1. Place the decoder equipped locomotive you want to program on the programming track If you are using operations mode ...

KB464 DT402 & DT400 - Programming Mobile Decoder Addresses

  Duplex Radio Throttle do not need to be plugged in to LocoNet to Program Decoders.  Simplex Radio & Infrared throttles must be plugged in to LocoNet to program CVs on the programming track. Ops Mode Programming can be done without plugging radio throttles in to LocoNet. IR throttles must be plugged in for Ops Mode Programming. 1. Be sure that only the loco you want to program is on the programming track. If you are using operations mode programming, the loco you want to program can be anywhere on the layout but it must have a decoder that is ...

KB595 Command Station Option Switches-Clear Slots and Factory Reset

Digitrax command stations have Option Switches that care used to customize their operation.  Command Station option switches should not be changed unless you fully understand what you are trying to accomplish.  Information on these Option Switches is included in each command station's manual.Be sure that you are changing the correct Command Station Option Switches as the unit can be crippled by closing the wrong switches.  NEVER CLOSE OPTION SWITCH #1!!Clearing your Command Station's Mobile Decoder SlotsMost command station problems are caused by filling up the command station's available slots by the following:1.  Operators failing to zero the speed of unused ...

KB98 Setting Up a Programming Track with DB150

If you want to change the address or other settings of your locomotive decoders, you must set up a programming track. It is very important that the rest of your railroad can be isolated from the DB150 and the programming track when you are programming a locomotive. Decoders are programmed when the DB150 command station sends programming information to them through the rails. There are two basic ways of programming decoders. Service mode programming broadcasts a message to all DCC equipped locos that are on the track. Because this is a broadcast method, you will need to set up a ...

KB99 Shutting Down & Resuming with the DB150

Shutting Down the System When you are finished with your sessionDispatching All Locomotive Addresses Some users prefer to “dispatch” or release all addresses active in their system before shutting down. This can prevent unexpected results when you power up the layout again. 1. Turn track power off: Press the PWR Key followed by the N - Key , the Track Power Indicator on the DT400 and the Track Status Indicator on your command station will go off. 2. Move the DB150 command station’s “MODE” switch to the “SLEEP” position. 3. Turn off the power supply to the system. Leaving the ...

KB100 DB150 - Track Power On and Off with a DT400 series throttle

How To Turn Track Power On and Off with the DT400 series throttle Turn track power on: Press the PWR Key, then press the Y + Key and the Track Power Indicator on your DT400 series display and on your command station will come on solid. If the track power indicator is blinking, press the Y+ key again to make it solid. Turn track power off: Press the PWR Key , then press the N - Key . The Track Power Indicator on your DT400 series and on your command station will go off. To Exit: Exit PWR mode by pressing the ...

KB101 DB150 Track Power Indications with DT400 Series Throttle

The DT400 series’ Track Power Indicator and the DB150’s track status indicator show whether track power is on or off. The first time you plug in your DT400 series throttle, track power will usually be off. To run trains, you will need to turn on the track power. Look at your DB150 and/or DT400 series to determine whether the track power is on or off. 1. When track power is off: DB150 TRACK STATUS indicator is off DB150 OFF LINE indicator is on and DT400 series Track Power Indicator is off (Track Power Indicator is a small dot in the top line on ...

KB102 DB150 Track Voltage Adjustment

The actual track voltage supplied by the DB150 can be adjusted. To do this, you must open the DB150 case (this will not void your warranty). 1. Open the DB150 case. Remove the black screws on the top and bottom of the case and slide the gray front panel off. Be careful to avoid disturbing components other than the ones described below. 2. Locate the small yellow trimmer potentiometer behind the LocoNet B Jack and Scale Switch. 3. Use a small screwdriver to turn the potentiometer clockwise to increase the scale voltage setting. Turn it counter clockwise to decrease the ...

KB104 DB150 Control Panel

The front panel of the DB150 Super Empire Builder has electrical connection points, indicator lamps, LocoNet connections and toggle switches which give status indications, configure and connect the unit for your railroad. Power Input The two “POWER IN” terminals on all Digitrax boosters & command stations are the power input connections. Please see the related articles about power requirements for the DB150. Power Supply Digitrax recommends the PS515 power supply to power the DB150. There are many other transformers and power packs that can supply the input power for the DB150. Check with your Digitrax dealer for suggestions. Most regular ...

KB105 Super Empire Builder Quick Start Guide

These instructions will get you up and running quickly. A full description of all controls and technical reference information are included later in this section of the Tech Support Depot. This section assumes that you are using a new set straight out of the box. If your set is radio equipped, we recommend that you follow this quick start guide without using radio to learn the basics. When you are successfully running your radio throttle tethered to the system, then go to the DT400 series tetherless overview article to learn how to install the radio option. Connect the DB150 to the ...

KB494 Upgrading Old Starter Set

Q:  I just purchased a used Digitrax set consisting of a DB150, UT2 and a PS515 for a very low price. What do I need to add to bring this up to current standards? A:  Because of Digitrax LocoNet, it is easy to add the latest components to upgrade on older starter set.  What you purchased was originally called a Genesis Starter Set.  The PS515 did not come with it but it is the perfect power supply for the DB150.   Your next step depends on what you want to do with your railroad.  In this case, the components you have will be ...

KB503 DB150 Power On LED Diagnostic Indications

Digitrax DB150 Command Station/Booster Power On LED Diagnostic BlinkingSteady on = DB150 is operating as a Command Station/Booster 1/2 sec on / 1/2 sec off = DB150 is operating as a Booster only 1 sec on / 1 sec off = DB150 is in Option (OP) mode, the Option switch is in the OPTN position 2 sec on / 2 sec off = DB150 is in Sleep mode, the Option switch is in Sleep mode Fast pulsing = DB150 is in Program Mode, the Option Switch is in PROG mode. Commands sent in this mode will program decoders that are ...

KB505 Command Station Audible Beeps - DCS100, DCS200, DCS240, DB150

The DCS100, 200, 240 and DB150 use several beeps and clicks that can be used as diagnostic tools that will help you debug a number of error conditions.   DCS100/200 Audible Sounds 1 Beep           DCS100/200 has powered on successfully or has sent a programming command. 3 Beeps         A loco address has been "purged" due to non-use. This is informational only and is normal. 4 Beeps         Booster short circuit shutdown. Fault Alarm. 6 Beeps         Command station already present in system. When two command stations are operating on the same system, you may experience unexpected results. 7 Beeps         DCS100/200 CMOS battery low ...