KB384 Zephyr Xtra and Zephyr - Can I add a booster?

Q:  Can I add a booster to my Zephyr? A:  Yes. Since the DCS51 Zephyr Xtra and DCS50 Zephyr are equipped with LocoNet, adding additional boosters is easy; you simply divide your railroad up into power districts and add the boosters and their individual power supplies. These are connected together using LocoNet cables. Because the Zephyr Xtra is rated at 3 amps and the Zephyr is rated at 2.5 amps: most boosters have higher ratings, you may want to have the Zephyr control a smaller area that has fewer power consumers (locomotives, lighted passenger cars), such as a main line ...

KB865 DB200+ - 8amp Booster Instructions

The DB200+ is the 8 amp booster. It has NO command station capability. This booster was designed for adding power to layouts that run lots of locos and for large-scale layouts where power requirements are heavy.DB200+ Control PanelNOTE: DB200+ front panel graphics may vary from those shown here.  Internally the booster is the same. These instructions are written for both versions of graphics as well as the DB200+ OPTO optoisolated version of the booster. About the Green Jumper WireEvery DB200+ is shipped with a green jumper wire on the front panel Booster Terminal Plug connecting Synch & Ground or ‘Config ...

KB419 How far apart to locate boosters

Q:  Your recommendation is to have a DB150 booster at no more than 50 foot intervals. Will one booster handle all track in that 50 foot area, i.e. a passenger terminal throat with many turnouts and switches? A:  The "50 foot intervals" applies to the maximum distance which boosters can be located from each other. This is a conservative recommendation.  You should consider how much power will be consumed in a district when locating boosters around the layout. If your power district is a single track railroad stretching over hundreds of feet of linear distance, boosters should be placed at 50 ...

KB102 DB150 Track Voltage Adjustment

The actual track voltage supplied by the DB150 can be adjusted. To do this, you must open the DB150 case (this will not void your warranty). 1. Open the DB150 case. Remove the black screws on the top and bottom of the case and slide the gray front panel off. Be careful to avoid disturbing components other than the ones described below. 2. Locate the small yellow trimmer potentiometer behind the LocoNet B Jack and Scale Switch. 3. Use a small screwdriver to turn the potentiometer clockwise to increase the scale voltage setting. Turn it counter clockwise to decrease the ...

KB135 DB200+ - Troubleshooting Heat Shutdowns

If the DB200+ booster shuts down frequently: 1. Move the DB200+ so that the heat sink has a flow of cool air. 2. Place the DB200+ out of direct radiant heat like sunshine or a room heater. 3. Try direct cooling by using a small fan to blow cool air onto the heat sink. 4. Lower the track load current. 5. Reduce the input voltage from the transformer. If the DB200+ beeps 4 times and shuts down briefly and then comes back on again, it is probably being run too close to its pre-set current limit. To solve this problem, ...

KB136 DB200+ - Autoreversing Booster

To make the DB200+ an Auto Reversing Booster follow the following steps: 1. Remove input power from the DB200+ by turning off the Input Power Supply. 2. Move the Mode Switch to the center P/R or OP position 3. Restore power to the DB200+ by turning on the Input Power Supply. Use the below diagram as a guide to configuring the DB200+ for Reverse Loops. Please note that for Auto Reverse applications the DB200+'s Mode Switch is set to the center P/R or OP position. Also note the DB200+ connections to the track- the DB200+ track connections are NOT directly ...

KB616 HO layout and 8 amp boosters

I was planning on purchasing the Digitrax Super Chief Radio 5 amps but several members in the club told me to buy them Super Chief Radio 8 amp for my HO Layout.  They said you will need the power when you start expanding.Question:Is it ok to use the 8 amp version for my HO layout?Answer:Yes it is fine to use 8 amp Digitrax boosters on your HO layout.  The choice between 8 amp and 5 amp command station/boosters, it is a question of how much power your railroad is likely to consume on your railroad as it is built today.  ...

KB103 Troubleshooting DB150 Shutdowns

If the DB150 unit shuts down occasionally due to a track short circuit: 1. Correct the short circuit condition and the booster will resume normal operation. 2. Turning off the booster when a short occurs is not necessary since it will re-start automatically when the short is cleared. If the DB150 unit shuts down frequently: 1. Move the DB150 so that the heat sink has a flow of cool air. 2. Place the DB150 out of direct radiant heat like sunshine or a room heater. 3. Try direct cooling by using a small fan to blow air onto the heat ...

KB78 Case Study: Nemo Junction - Basic Wiring Part 2 of 9

Although this is a simple railroad, it will have some advanced features. When the railroad's sectional modules are first assembled, the electrical connections are simple. The railroad will be controlled with a DCS50 Zephyr, using a PM42 Power Manager for short circuit protection. One section of the PM42 will control the inner oval of track, a second section of the PM42 will control the outer segment. This is done so that if a train derails on one loop, the train operation on the other loop will not be affected. Because the DCS50 is rated at 2.5 amps, the PM42 must ...

KB1007 PS2012 - Overview and Installation

Regulated power supply delivers more power with less heat for more efficient booster operation. Operates up to 4 Five amp boosters. Scale selectable for use with N, HO or large scale. DC Ammeter. On/Off Switch. Integral cooling fan. Design coordinated for use with Digitrax products. One "Y" Cable (P/N YC52) Included for convenience with dual 5 amp protected outputs All secondary devices must be properly fused on their power input leads for their rated capacity. For example if you intend to use the PS2012 to drive a 5 and an 8 amp booster, you must input fuse these devices for ...

KB113 Boosters and Power Management

What is the difference between boosters and power management? A Booster is the device that provides the electrical power to the railroad. Most Digitrax command stations have a combined booster. The command station generates the DCC signal then sends it through a booster to the layout. A small model railroad may only have the command station and booster, while a large railroad will have numerous boosters. Multiple boosters provide more power to larger layouts.Additional boosters receive the DCC signal from the command station via LocoNet. Power management usually refers to the devices which act as circuit breakers and power distributors. ...

KB534 Short Circuit when adding a DB100 or DB150 booster to a DCS100 or DCS200 Command Station

Q:  I recently split my layout in half, with a DB150 acting as a booster powering one side and a DCS100 powering the other. I'm trying to reconnect the bus feeders to the rails, which all worked properly before the split. Now when I reconnect the feeders there is no short indication, BUT when a loco goes over the insulated gap between the two sections, a short occurs. A:  This is a common issue when the first booster is added to a DCS100/DCS200 command station. MOST DCS100/DCS200 command stations come from the factory set with Rail A & Rail B connections that are the opposite ...

KB151 Technical Note About DCC Booster Output Ratings

Digitrax boosters have maximum output current limits of either 5 or 8 amps. The actual continuous output current that your booster will provide to the layout depends on several factors including the input supply voltage, the ambient room temperature and air flow over the booster's heat sink. Higher input voltages increase the amount of heat that must be dissipated by the booster's heat sink. If the heat sink does not get enough air flow to allow for heat dissipation, the booster will eventually reach an over temperature state and shut down. A small fan blowing across the heat sink on ...

KB826 Zephyr - Adding Another DCS50

You can add a second Zephyr to add more power and an additional throttle on the DCS50 and two additional Jump ports for using DC power packs to control DCC locomotives.  You will need to change Option Switch 02 to c (Closed) on the second (and any additional DCS50s you might choose to add to the layout as well).  The diagram below shows you how to do this.