KB971 PM42 - Power Input Requirements

Can I combine the power input requirements for PM42's with other units for economy?Digitrax recommends each PM42 module to have its own seperate power source. The criteria for choosing a power supply for the PM42 is any power source that can deliver 12-15V AC or 13.8-15V DC with a minimum of 125 ma. The Digitrax PS14 meets the minimum power requirement of a PM42.It is possible to power more than one PM42 from a single power source. When powering multiple PM42's special care must be taken to insure identically phasing of all PM42's and ample current availability to power all ...

KB567 DS54 Power Options

  There are two methods of providing power to the DS54: from the rails and from an auxiliary power source. The DS54 can be powered from the rails however, Digitrax strongly recommens that the DS54 be powered from an auxiliary power supply capable of delivering 12-16 volts (ac or dc) at 300 millamperes for best results.  Powering the DS54 from the rails reduces the current available to power locomotives and lighted rolling stock.  The auxiliary power supply connections are the red (+) and black (-) wires. Note: Digitrax recommends the PS14 Power Supply for independently powered DS54’s. Multiple DS54’s can be powered from a single power ...

KB268 Powering the SE8C

What are the power requirements of a SE8C? Any power supply that can provide 12-15 volts either AC or DC with a minimum current rating of 100 ma is all that is necessary to power a single SE8c. Digitrax recommends the PS14 for powering the SE8c. A single PS14 has the ability to power two SE8c’s. When connecting multiple SE8c’s to a single power source the total maximum current requirement of the power source is computed by multiplying the number of SE8c modules by 100 ma (Example: 3 SE8c’s would require a 300 ma power supply - 3x100=300). The edge ...

KB195 PR3 - Hardware Setup

SoundLoader and PR3 have been tested to work on PC compatible computers running at 550MHz and up with Windows XP or Vista, 512MB of RAM. Other combinations of hardware and software such as Windows 98 may also work, but are not supported by Digitrax, and have not been tested to operate properly. Installation consists of three steps: Hardware installation, software installation, and software setup. Below is a photograph of the actual hardware connections required for SoundFX programming. Assemble the PR3 hardware as shown in the diagram below and connect to an appropriate power supply (Digitrax PS14 or equivalent). Note the ...

KB590 Q&A - Powering DS64

  Q:  How do you connect more than one DS64 to a single power supply like a PS14 to power them or do you need a separate power supply for each DS64? A:  One power supply can be used if it can provide adequate power for all the DS64s it is powering. The PS14 has a built-in circuit breaker; when it exceeds its capacity, it will shut down, cool off and then start up again. If you are experiencing this behavior then you need to add one or more PS14s to provide enought power for the DS64s you have connected. Our recommendation of one ...

KB171 PR3 - Stand Alone LocoNet Interface Applications

Under what conditions can the PR3 be used as a Stand Alone LocoNet Terminator? The PR3 is so designed so that it can be configured to act as a stand alone LocoNet controller in the event that a Digitrax command station is unavailable for the control of a series of LocoNet compatible devices. There are two major situations that would require the PR3 to act as a stand alone LocoNet controller. The first situation is where one of the many advanced features offered by the LocoNet and the various LocoNet compatible devices is desired to be used on a layout ...

KB702 UP5 Power Supply and Track Indicator Connections

Hooking up the UP5's Power Supply (Optional but highly recommended to make sure LocoNet voltage is adequate to control large layouts)The optional power supply (PS14) can be connected to one or more UP and/or UR panels to provide additional power for LocoNet operation and for battery saving power to any Digitrax throttle that is plugged into any of the powered panels.1. Plug the PS14 into the DC jack located on the side of the UP5 circuit board.2. Connect the +Common point on each additional board (located between the two LocoNet jacks) to the powered board with 22AWG wire (Figure 2). ...

KB352 Powering your Digitrax Command Control Railroad

Digital Command Control (DCC) has specific electrical requirements that must be provided for your layout control system to operate properly.Input PowerAll DCC systems require an external power supply.  Digitrax manufactures several power supplies for our command stations and boosters: The 3 Amp PS415 (the Zephyr Xtra power supply) The 5 Amp PS515 for all Digitrax 5 amp command stations and boosters The powerful 20 Amp PS2012 can be used for multiple 5 and 8 amp command stations and boosters  Additionally, the PS14 is available to power various other devices for your railroad.  Digitrax strongly encourages you to use our power supplies to insure satisfactory ...