KB480 PM42 - Power Management Circuit Breaker Control

Q: What is the basic configuration and OpSw settings for a section of the PM42 when configured for circuit breaker control? A:  The PM42 is a 4 section multi-purpose device where each of the four sections can be individually configured to act as either a circuit breaker, or automatic reverse loop controller. The PM42 monitors the current flow to the rails and interrupts the connection when it senses that the current demands exceed the upper allowable current level determined by the User controllable Option Switch (OpSw) settings. The power flow of a layout's command control system starts with the command station, or ...

KB481 PM42 - Automatic Reverse Section Control

  Q:  What is the basic configuration and Option Switch (OpSw) settings for each of the four sections of the PM42 when configured for automatic reverse section control? A:  The PM42 is a 4 section multi-purpose device where each of the four sections can be individually configured to act as either a circuit breaker, or auto-reverse section controller or DPDT relay. When configured as an auto-reverse section controller, the PM42 adjusts the rail phasing of the reversing section it controls whenever a locomotive, or car with metal wheels, bridges the gaps between the rails of that reverse section and an adjacent non-reversing section ...

KB197 The Layout - Some thoughts on troubleshooting

  The most common problems on the layout that will impact your DCC system are electrical short circuits. If you find that you cannot get the Track Status light on your command station to come up, or there are numerous beeps from the booster, then disconnect one of the Rails from the booster and the problem should be apparent. There is an electrical short in your layout wiring. The quarter test is the BEST diagnostic tool that you have! With your DCC system up and the Track Status ON, create a short circuit across the rails of the layout every ...

KB231 Zephyr - What does "SLP" mean on the DCS50?

What does SLP mean on the DCS50? The "slp" message on the DCS50 means that the unit thinks it is temporarily in sleep mode. This may occur if the LocoNet data line is grounded for more than 1/8 of a second. You may initially try to exit Sleep Mode by cycling the "Exit" key on the DCS50, or powering down and repowering the unit. If this problem continues, you must check your LocoNet for a shorted connection.

KB103 Troubleshooting DB150 Shutdowns

If the DB150 unit shuts down occasionally due to a track short circuit: 1. Correct the short circuit condition and the booster will resume normal operation. 2. Turning off the booster when a short occurs is not necessary since it will re-start automatically when the short is cleared. If the DB150 unit shuts down frequently: 1. Move the DB150 so that the heat sink has a flow of cool air. 2. Place the DB150 out of direct radiant heat like sunshine or a room heater. 3. Try direct cooling by using a small fan to blow air onto the heat ...

KB308 PM42 - Local Annunciation

How can I remotely monitor the input and output status of a section of the PM42 that is configured to act as a circuit breaker at a remote location? The final output stage, of each section, of the PM4 or PM42 is a DPDT relay. The contacts of this relay act in a similar fashion as the contacts of a DPDT toggle switch. These inputs and outputs can be monitored in a variety of ways. Three common monitoring devices are a LED (with appropriate resistor), a lamp (of the appropriate voltage), or an optical coupler (with appropriate resistor). The following ...

KB534 Short Circuit when adding a DB100 or DB150 booster to a DCS100 or DCS200 Command Station

Q:  I recently split my layout in half, with a DB150 acting as a booster powering one side and a DCS100 powering the other. I'm trying to reconnect the bus feeders to the rails, which all worked properly before the split. Now when I reconnect the feeders there is no short indication, BUT when a loco goes over the insulated gap between the two sections, a short occurs. A:  This is a common issue when the first booster is added to a DCS100/DCS200 command station. MOST DCS100/DCS200 command stations come from the factory set with Rail A & Rail B connections that are the opposite ...

KB505 Command Station Audible Beeps - DCS100, DCS200, DCS240, DB150

The DCS100, 200, 240 and DB150 use several beeps and clicks that can be used as diagnostic tools that will help you debug a number of error conditions.   DCS100/200 Audible Sounds 1 Beep           DCS100/200 has powered on successfully or has sent a programming command. 3 Beeps         A loco address has been "purged" due to non-use. This is informational only and is normal. 4 Beeps         Booster short circuit shutdown. Fault Alarm. 6 Beeps         Command station already present in system. When two command stations are operating on the same system, you may experience unexpected results. 7 Beeps         DCS100/200 CMOS battery low ...

KB477 PM42 - Third Party DCC Command Systems

  Q:  Can I use a PM42 with a non-Digitrax DCC Command system? A:  The PM42 was specifically designed to work with Digitrax Direct Home wired layouts. Any system that is configured this way will probably work with the PM42 with no interoperability issues. Digitrax has no control over or knowledge of each specific non-Digitrax system and how it may interact with the PM42. The PM42 can be used as a stand-alone auto-reversing unit and short circuit manager with many third party DCC systems, but for systems without LocoNet capability a number of the networked management features will not be available. ...

KB478 PM42 - Power Management of an Auto Reversing Section

Q:  What is the preferred way of protecting a reverse loop with circuit breaker management and still having automatic reversing? A:  There are two ways of protecting a reversing section with a circuit breaker and reversing section controller. 1.  Use one PM42 (circuit breaker manager) and one AR1 (automatic reversing section controller). 2.  Use two PM42s (one as a circuit breaker manager and one as a reverse section control). The following diagram displays both methods: a) The first method (left), is where one section of a PM42 configured for circuit breaker operation feeds one or more AR1s (automatic reversing section controller), or b) The second method ...

KB479 PM42 - Auto-Reverse Section Protection with Circuit Breaker Manager with a Single PM42

Q:  Can two sections of a single PM42 be configured to perform both the task of a circuit breaker and also automatic reverse section control for a single reverse loop? The PM42 can be configured so that one section of the PM42 is used for circuit breaker operation, feeding into another section of the same PM42 which is configured for automatic reverse section control. In the field, this configuration has been found to be unreliable in some layout configurations.  If you are having problems getting this to work in your setting, we recommend using an AR1 to handle the automatic reversing secion.  The ...