KB161 Reverse Loops Galore

We have designed a layout at my place with double main line with reverse loop at each end. Plus there is a branch line with two reverse loops that in one loop is connected to the main line. The main lines stay double track even at the split. The branch stays single with only one connection with the main. My plans where to use the AR1 for all my reverse loops and the PM42 for my power control. What if any problems do you see with all these loops? Nothing, if you can guarantee that at any given time only ...

KB603 Zephyr - What components are needed to wire a reverse loop?

Since many Zephyr and Zephyr Xtra Starter Sets are used on smaller railroads, a natural choice for setting up an automatic reversing section would be an AR1. If you have more than one reverse loop, then the PM42 is a better choice. These automatic reversing strategies will work equally well for any Digitrax system using any Digitrax Starter Set.  Alternately for larger railroads, an auto reversing booster such as the DB150 can be used for automatic reversing if the section is large.

KB411 AR1 with BD4 for Block Detection

How do you wire an AR1 with a BD4 so that you get block detection within the reverse loop and without the BD4 permanently detecting the AR1? It should be wired with the AR1 between the power source and the BD4. All four detection sections of the BD4 will have to be inside the reverse loop.

KB781 AR1 Auto-Reverser Trip Current Adjustment

The tuneable trip current (TTC) adjustment allows you to set the current at which the reversing section reverses when the train crosses the gap into the section. This allows you to improve the operation of your reversing sections.The tuneable trip current is adjustable from .25 amps to 8 amps. Turning the TTC screw clockwise increases the current trip point and turning the TTC screw counterclockwise decreases the current trip point. The total adjustment is approximately one half revolution of the TTC adjustment screw. The TTC adjustment is made using a full load on the reversing track--the total number of locomotives/cars ...

KB493 Digitrax AR1 or Circuitron AR-1

  Digitrax AR1 is a DCC Automatic Reversing Controller.  We have become aware of another product of a similar name that may cause our customers some confusion. Circuitron makes an automatic reversing unit called the AR-1 that is used for automatic reversing of analog powered trains. The Digitrax AR1 is not the same device and does not work in the same way.

KB558 AR1 with Two Power Districts

Q: I want to use the AR1 for a reverse loop between two different power districts (i.e. different booster for each connected track). Is this possible or do I need to make a special wiring set-up to do this? SThis diagram shows how to do this The usual rules apply, the AR1 track section must be longer than the longest train you will run.

KB621 Power Management Overview

Power Management is a concern on every layout.  With Digital Command Control, the main concern is that enough power is supplied to evey track section on the layout so that the digital signal is transmitted to the decoders in the locomotives and turnouts.Each locomotive uses power from the track, some for the motor, some for headlights and other functions and some for the command control electronics in each locomotive.  More electrical power is necessary to run more locomotives on the layout.  Digitrax boosters provide between 2.5 amps & 8.0 amps.  A small N Scale or HO Scale layout with two to ...

KB596 Automatic Reversing and Turnout Control

Q: How do I use the AR1 and automatically control the turnout? I'm confused here. It is good that the AR1 controls the switching of the track power for a reverse loop automatically but it seems the turn out direction also needs auto control. Am I missing something here? Need help understanding...Please explain. A: The AR1 is handles correcting the track polarity mismatch when a reversing section is encountered by a locomotive. When the polarity inside the reverse section does not match the polarity outside the reverse section, the AR1 detects the short circuit and flips the polarity so that ...

KB782 AR1 Auto Reverser Installation Instructions

The AR1 is usually located close to the point where the gaps are cut for the reversing loop. The length of the reversing loop is determined by the maximum length of the train that will use the loop.1. Turn off track power. (Note: Failure to turn off power before connecting your AR1 may damage your AR1.)2. Connect Track Power from Rail A and Rail B mainline to the AR1. Rail A connects to terminal 5 and Rail B connects to terminal 4.3. Connect the wires from the reversing section to terminals 1 & 2 on the AR1. (Note: terminal 3 ...

KB916 PM42 and AR1 - Setting PM42 Sensitivity

When using the your PM42 with an AR1 Auto Reversing controller do not use the "fastest setting" in the Short Circuit Sensitivity Settings section:

KB539 AR1 - Special Considerations

  One major consideration is that the reverse section controlled by the AR1 must be longer than the longest train. It is a common misconception that the AR1 will work with an analog controlled ("DC") locomotive; it will not. The AR1 is meant to be used only in a DCC enviroment. The AR1 coordinates the phasing of the reversing section with that of the mainline (non-reversing) section of the layout.  Because a Digitrax layout can be a complex enviroment with detection and transponding, etc. consult the approriate Digitrax user manuals and the Digitrax Tech Support Depot knowledge base.  

KB478 PM42 - Power Management of an Auto Reversing Section

Q:  What is the preferred way of protecting a reverse loop with circuit breaker management and still having automatic reversing? A:  There are two ways of protecting a reversing section with a circuit breaker and reversing section controller. 1.  Use one PM42 (circuit breaker manager) and one AR1 (automatic reversing section controller). 2.  Use two PM42s (one as a circuit breaker manager and one as a reverse section control). The following diagram displays both methods: a) The first method (left), is where one section of a PM42 configured for circuit breaker operation feeds one or more AR1s (automatic reversing section controller), or b) The second method ...

KB479 PM42 - Auto-Reverse Section Protection with Circuit Breaker Manager with a Single PM42

Q:  Can two sections of a single PM42 be configured to perform both the task of a circuit breaker and also automatic reverse section control for a single reverse loop? The PM42 can be configured so that one section of the PM42 is used for circuit breaker operation, feeding into another section of the same PM42 which is configured for automatic reverse section control. In the field, this configuration has been found to be unreliable in some layout configurations.  If you are having problems getting this to work in your setting, we recommend using an AR1 to handle the automatic reversing secion.  The ...