KB83 SE8C - Resetting SE8C

If you want to reset the SE8C to its factory settings, follow this procedure: No track power is required for testing, but you will need a working LocoNet connection and throttle, or a PC running DCC control software that is connected to LocoNet. a. Press and hold the Option Button until the red LED starts to blink. b. Release the button, the red and green LEDs will blink alternately indicating that you are in Option Switch programming mode. c. Go into SWITCH mode on your throttle or PC. d. Select Switch 20. e. Close and then Throw the switch to ...

KB613 Throttle Jacks vs. LocoNet Jacks

The jacks on the front and sides of the UP5, UR92, UR91, UR90, and LNRP front panels are Throttle Jacks and should only be used for connecting throttles to LocoNet.  They should not be used to connect to other LocoNet devices.  The jacks on the back of these units are LocoNet Jacks that are used for connecting LocoNet devices to the network.  Technically speaking! These units were designed to have the FRONT jack's second Railsync differential signal run as a diode-or'ed power source (for throttles).  This means that some cable orientations and power loads could cause unexpected operations in downstream LocoNet devices ...

KB588 BDL168 - LT5 Tester

There was an error In the BDL168 Instruction Sheet, Figure 6 on Page 19.  The LT5 diagram was incorrect.  This article shows the correct LT5 Detection Sections.  The current on-line version of the BDL168 Instruction Sheet has been corrected. Each BDL168 comes with an LT5 that will help you with layout wiring and troubleshooting for transponding & detection. The LT5 plugs onto the LED header connections of BDL168 and the LEDs on the LT5 light when detection sections are occupied. The status of power to each zone is also shown. In service, the LT5 is plugged in to one of ...

KB47 BDL168 - How to Change the Option Switches

How to read back and change BDL168 Option Switches (OpSw): 1. Power up your BDL168 and connect it to LocoNet. 2. Connect a DT series or UT1, UT2 Digitrax throttle to one of the the BDL168's LocoNet connectors. NOTE: The UT4 will not work as its design is different for the original UT series throttles.3. Press the switch behind the red option LED for about 1 second, then release it. The red option and green ID LEDs will flash alternately to let you know that you are in option switch setup mode. 4. Go into SWITCH mode on your throttle. ...

KB50 BDL168 - Using with Power Managers

The BDL168 is designed to be used with power management devices such as PM42. The BDL168 is designed to operate “downstream” of the Digitrax boosters and power management devices. The BDL168 is the "last" device in the chain from booster to power manager to BDL168. It is connected directly to the track detection section. There should be no other connections to any detection section that will draw track power or the detection section will always show occupied. If a device is used to switch off power feeding the BDL168 and the track it is connected to, for example, a PM42 ...

KB51 BDL168 - Using In a Reversing Loop

The BDL168 can be used as an autoreversing unit for return loops. One of the BDL168 Detection Sections is connected to the non-reversing area, with the balance of the detection connections being made within the reversing area. Here is a wiring example: Note that an auto-reverse section can only use detection sections that are contained in a BDL168 zone that is correctly set up for auto-reversing.

KB84 SE8C - Initial Setup & Testing

We recommend testing your new SE8C prior to installation on your layout. The following testing procedures will help familiarize you with the general operation of the SE8C. Track power needs to be ON, a working LocoNet connection and a throttle or PC running DCC control software. Pre-Installation Set-Up 1. Solder one wire from a 12V AC or 15V DC power supply to Pin 3 and the second wire from the power supply to the Pin C on the 44-Pin edge connector; this powers the SE8C. Digitrax manufactures the PS14, which is appropriate for this installation. Multiple SE8Cs can be powered ...

KB53 BDL168 - Outdoor Layouts

Reducing Sensitivity for Outdoor Layouts Outdoor layouts may require reducing sensitivity to allow for more accurate occupancy reporting through the BDL168. Resistors are connected between the detection zone and the zone common from the blue connector to reduce sensitivity. A 1KOhm resistor will reduce the sensitivity by 1/2. A 100 Ohm resistor will reduce sensitivity by a factor of 10.

KB54 BDL168 - Troubleshooting Checklist

Here are several things to check if you are having trouble with the BDL168: Proper Wiring Be sure that you have NOT connected pin 11 to pin M, as this can prevent proper LocoNet communication. Check to make sure not wires are touching adjacent pins.  Follow the wiring diagram closely. Packet Reception Be sure the green ID LED is ON & is “winking” off about every 2 seconds. This means that correctly formatted DCC packets are being decoded from the left most (Railsync) pin of the RJ12 LocoNet socket. For DCC detection, the same DCC packet signal that drives the ...

KB57 BDL168 - Connecting to a "Common Rail" Wired Layout

Common Rail Wiring Many older model railroads use Common Rail wiring because they were initially wired to operate with electrical toggle switches. Conversion to DCC is possible with Common Rail, but it is not recommended. Whole layout common rail is a method of wiring layouts where power districts and their boosters are electrically connected using a common rail or common power bus return wire. Whole layout common rail wiring is a disadvantage when it comes to detection systems since detectors cannot independently monitor whether zone power is on or off so they can't tell whether occupancy detection is working in ...

KB61 BDL168 - Using two boosters

Is it possible to connect my BDL168 across two power districts (Boosters). I envisage using zone 1 & 2, with detection sections 1-8 one one booster (DCS100), with zones 3 & 4, with detection sections 9-16 on another booster (DB150). Will this work? Please refer to the chart below: Note that Pins 1 & A, 6 & F, 13 & P, and 18 & V are identified as "Connection to Booster for Zone *. Each Zone can support up to four detection sections. So, for your application, the DCS100 would be connected to Pins 1 & A and 6 & ...

KB607 Resistance wheel sets

Railroad signaling works based on detection of trains on the railroad.  If a train is detected, then the signal system goes into action, setting up indications that let show that the track section is occupied and warn other trains that the section is occupied.  At a grade crossing where a railroad and a highway intersect, the presence of a train starts the crossing signals and lowers the gates in time to stop highway traffic so the train can pass.In the case of real railroads, detection is easy, since the rails are naturally insulated from each other and either a locomotive or ...