649 Search Results For how many operators during operation session

KB976 PM42 Shut Down During Operation

When I get several locos in the same PM42 sub-district, the PM42 seems to shutdown at random times even though I am sure there is no short circuit, what is wrong?1.  The PM42 is set at the factory with a default current trip point of 3 amps for all 4 sub-districts. This is fine in most cases. 2.  If you plan to run more than two or three locomotives in a sub-district, you will need to increase the trip current. 3.  Use the minimum current set point that gives acceptable layout operation, i.e. minimum power interruptions when no short circuits ...

KB633 DT300 - Fast Clock Operation

Many operators use a fast clock during operating sessions to simulate prototypical operations. Traditionally, this clock is on the wall and is set up to run at a faster than normal rate. LocoNet has its own networked fast clock for all Digitrax throttles connected to your system.To use the Fast clock feature of the DT300, you must be plugged into a Digitrax command station.When there is no activity on your DT300 for more than about 6 seconds, the DT300 will revert to the default display. Your DT300 was shipped with Lo (Loco) mode, showing the current speed of selected loco(s), ...

KB456 DT402 & DT400 - Fast Clock Operation

Many operators use a fast clock during operating sessions to simulate prototypical operations. Traditionally, the fast clock is on the wall in view of the train operators; it is set up to run at a faster than real time so that an operating session can simulate prototypical operation on a compressed time scale. LocoNet has its own networked fast clock for all Digitrax throttles connected to your system. The fast clock display is a 4 digit 12 or 24 Hour format clock. To display the fast clock simply press the CLOC c Key. The fast clock display will remain active while ...

KB460 DT402 & DT400 - Operations Mode Programming

Ops Mode programming, also known as "Programming on the Main" lets you change the configuration of an individual decoder while the locomotive is on your railroad without having to move it to the programming track.Operations mode programming lets you program CVs in DCC locomotives equipped with Ops mode capable decoders while they are on the mainline. A typical use for Ops mode programming would be to change the acceleration rate (CV03) or the deceleration rate (CV04) of your locomotives to simulate the weight and braking capability of the train to compensate for changing the number of cars or power units on a ...

KB426 DT400/R Tetherless Operation - Safety Selection Feature

While tetherless, the DT400/R operates as a one-way transmitter. The DT400/R must be plugged into LocoNet to select an available locomotive address. After an address is selected on your DT400/R, you can unplug from LocoNet and run the selected addresses with infrared or radio. The throttle will automatically convert to infrared or radio operation for all speed, direction, function, operations mode programming, and switch commands. Digitrax uses this safety selection procedure, which requires throttles be plugged into LocoNet to select a loco address to run. This is an important operational safety feature. Digitrax chose not to allow one way address ...

KB974 PM42 - Power Drop During Short Detection

My PM42s seem to correctly trip on track shorts and auto-reverse reliably, but the power briefly drops out during these events, and when the PM42s attempt a fault recovery into a persistent short circuit, why is this?No power on earth can stop the track voltage of the booster from collapsing to a low value when a true short circuit is present. This is simply Ohm’s law in action!Actual track voltage seen depends on: the loop resistance of the short circuit, the current capacity of the booster and power supply and whether the Booster employs "smart" fault detection and recovery along ...

KB176 Analog Operation of Digitrax Decoders

What about using a Digitrax-decoder-equipped locomotive on a layout having only DC power?It is possible, but analog operation of DCC equipped locomotives is becoming a bit of a rarity. In earlier times some locomotives were delivered from the manufacturer with a DCC decoder in place and a jumper plug was used to select the operating environment. Digitrax still offers a jumper plug for use in some configurations; you remove the decoder and replace it with the DHDP or DNDP. With later generations of decoders, it is possible to operate on a DC layout with the decoder in place. To quote ...

KB858 Zephyr - Shutting Down & Resuming Operation

When you are finished with your session, you should shut down the DCS50 by turning off power to the system.Shutting Down DCS50 Zephyr1. Bring all locomotives on the layout to a stop by setting set the Throttle Knob for each loco to STOP. 2. Turn track power off: Press the POWER key, the DCS50's Track Status Indicator Dot will go off. The display will briefly display "Po" followed by two characters, the Po means power off, the two characters indicate which software version is installed in the unit. The display will automatically revert to showing the last loco address selected ...

KB555 DCS100 Command Station/Booster Expanding Available Slots

A slot is a memory location in the command station that holds an active decoder address.  The number of slots is the number of locomotives that the command station can support in operation at a time. When the available slots are filled with decoder addresses, trying to select another locomotive address to run generates the "slot=max" error code.  When all the slots are full you can't select another address until one is released from the system. See Clearing your Command Station's Mobile Decoder Slots below for how to prevent this from happening.The DCS100 Command Station/Booster that is included with Super Chief Xtra and other ...

KB459 DT402 & DT400 - Busy or Fail Message During Programming

A  “Busy” message during programming means that the system is temporarily busy.  Simply try the task again.  When the system is no longer busy, you will get a “Good” response. A  “Fail” message during programming means that there is a problem with the locomotive on the programming track.  Check to be sure the loco's wheels are making good contact with the programming track.  Make sure that the decoder is properly installed in the locomotive.   Make sure the connections to the programming track are secure.  Make sure the programming track is powered. 

KB661 DT400 Slot=Max Error Message

Does your throttle say slot=max ?This means that the system's capacity to handle operating locos is full. The DCS100 can run up to 22 or 120 addresses at the same time. If you have the slot=max message, be sure that all locos that are not running are released from throttles or set DCS100 OpSw 44 to closed to increase the number of address slots available to 120. The DCS100 command station that comes with all Genesis, Empire Builder and Chief series starter sets are set with a factory default of 22 slots.  So, once you begin to operate significantly more locos, you may need to ...

KB373 LNRP - Installation & Operation

Installation: Figure 1 shows the general arrangement for connecting one or more LNRP's to configure a LocoNet based system for operation. Note that the LNRP's drive the power and Railsync signals on the "standard" LocoNet cable segments, so each LNRP should have a DC input of +15V to +18V at up to 250mA supplied on the side DC power jack. Note that the shaded cable connections are made from the protected network side connections of the LNRP units to the components that are on the "protected" or high reliability part of the System. The other solid cable connections are the ...

KB587 AC Motor Operation

I want to run a small 12V -16V AC motor via DCC and am not sure if you have a decoder for this and if so how to connect up.For Variable Speed:Some Digitrax decoders, such as the DG583S, can be programmed to operate AC motors. When you program CV61 to a value of 004, Digitrax decoders with split field motor drive capabilities will convert their motor leads to drive a "split field" AC motor instead of the default DC motor. This lets you run Maerklin 3-pole AC motors and similar motors in a number of locos built in Europe with ...

KB595 Command Station Option Switches-Clear Slots and Factory Reset

Digitrax command stations have Option Switches that care used to customize their operation.  Command Station option switches should not be changed unless you fully understand what you are trying to accomplish.  Information on these Option Switches is included in each command station's manual.Be sure that you are changing the correct Command Station Option Switches as the unit can be crippled by closing the wrong switches.  NEVER CLOSE OPTION SWITCH #1!!Clearing your Command Station's Mobile Decoder SlotsMost command station problems are caused by filling up the command station's available slots by the following:1.  Operators failing to zero the speed of unused ...

KB854 Zephyr - Brake Operation

To use the pre-set braking rate to stop and start a locomotive: Move the Direction Control Lever [ 2 ] to the BRAKE position, the Brake Indicator Dot will begin blinking and the loco will slow down to a stop at the brake rate you have set up in the Zephyr DCS50. As the loco slows to a stop, the Brake Indicator Dot will change from blinking to steady on to let you know that the brake is on.Move the Direction Control Lever to the FORWARD or REVERSE position and the loco will accelerate at the programmed brake rate to ...

KB903 BDL162 - Adding a Heatsink for Large Scale Operation

How do I add a heatsink to my BDL162 for large scale operations?The BDL162 design does not include a provision for a heatsink. There is not a kit available for adding on a heatsink, but you can make your own if you believe it necessary for your system. The following drawing will provide the correct measurements to produce a heatsink that will slip in between the two rows of rectifiers on the BDL162 Circuit Board. This will raise the current handling capacity but we do not know by how much.Cut the heatsink from .05" thick aluminum or brass sheet stock, ...

KB201 Case Study: Texas & Southwestern Part 10 of 11 - Operations

A model railroad continues to be interesting if there are opportunities for growth and for operation. Extra detail can be added, scenery can be enhanced, but in the end, if the railroad is interesting to operate, it will continue to be a source of enjoyment for its owner for many years. The Texas & Southwestern has many opportunities for interesting train operations. The Texas & Southwestern is both a passenger railroad and a freight railroad. Passenger Point to Point Our trusty RDC (rail diesel car) allows for one train to operate in a point to point fashion. In fact, all ...

KB476 Operations Mode Read Back - Minimum Transponding Hardware Configuration

Operations mode (OPs mode) programming allows you to program decoders on the layout instead of having to move them to a separate programming track.  This is a write only programming method.  If you want to be able to read back the values written to a particular decoder using Ops Mode programming, you will need to install transponding on the layout.  If transponding is not active on the layout, you must use an isolated programming track for reading back CV values.The extent of the area with OPs Mode readback available depends on how muchof the layout is instrumented for transponding. The ...

KB475 DT400 Series Throttle - Operations Mode Read-Write

  Q:  How can I write and read the Configuration Variables of Mobile Decoder on the mainline using the DT40x Throttle? A:  Operations Mode Programming, also known as Ops Mode, lets you program a locomotive decoder's CVs while it is on the main line. With the addition of transponding in Ops Mode, you can write and read back CVs in DCC locomotives equipped with most modern decoders while they are on the mainline. Some older decoders before Extended Packet Format was used are not able to do this.For example: A typical use for Ops mode programming would be to adjust an engines ...

KB233 CV29 - Analog Mode Operation

  CV29 is assigned a single value which chooses a combination of specific effects: 1. Speed step control. 2. Speed table On or Off. 3. Analog mode conversion On or Off. 4. Normal Direction of Travel (NDOT). 5. 2 digit addressing or 4 digit addressing. Analog Mode Analog mode conversion is very convenient if you plan to run your Digitrax decoded locomotive on regular DC layouts. With analog mode conversion enabled, the decoder will automatically begin operating as a DC locomotive when no DCC signal is detected by the decoder. This means that if you place your Digitrax decoder equipped ...

KB898 CTX/CTY Throttle Operation

CTX/CTY throttles allow you to have up to 4 separate throttles controlled by 4 different operators rather than 4 throttles controlled by one operator as in the CT4 that comes with your Challenger Set. Digitrax provides these instructions so that you can build your own throttles to your own specifications. You are free to choose any knobs, buttons & cases you like, the ones on the parts list below are just suggestions. These throttles give you the option of expanding your operations cost effectively. The CTX throttle controls speed & direction for one train in the operating group & can ...

KB159 Lots of Locomotives, Few Operators

  My layout is in N scale, with an 85 foot double track main, a 12 track storage area, small yard, and engine facility. The layout measures 10 X 14 with two helices. There are a total of 34 engines, many of which are with their trains in the storage area. All of the already made-up trains (11) have two or three engines on them, ready to be brought up via a helix to run on the railroad. Currently, the road is divided into six parallel blocks (DC); 12 blocks in all. In the future, I plan on adding a ...

KB427 DT400, DT402, DT500 Series Tetherless Operation - LocoNet ID Change

If you are operating in a show environment where there are other model railroads operating which use Digitrax wireless throttles, you must insure that your railroad's LocoNet ID is different from others that are also present. Your throttle will log on to the LocoNet ID offered by compatible infrared or radio receiver it sees when plugged in to LocoNet. The default LocoNet ID is 00. It may be necessary to change the LocoNet ID if more than one club is operating in close proximity at a train show so that the commands sent by one club will not interfere with ...

KB845 Zephyr - Operations Mode Programming

Programming On The Mainline: Operations Mode ProgrammingOperations Mode Programming [Ops Mode] lets you program CVs in DCC locomotives equipped with Extended Packet Format decoders while they are on the mainline.  This is handy for situations where you want to make an adjustment to a specific locomotive while it is in service.  There are also situations where mobile decoders from other manufacturers can only be programmed in this manner. A typical use for Ops mode programming would be to change the acceleration rate (CV03) or the deceleration rate (CV04) of your locomotives to simulate the weight and braking capability of the ...

KB694 TF4 - Testing for correct transponder operation

Testing the installed TF4 for correct transponder operation1. Place the unit with the installed TF4 on an empty transponding track section. This test assumes that the transponding track section is already set up, tested and is working before you start TF4 testing.2. Using a DCC throttle, select the TF4 address that was programmed into the TF4 and verify that the transponder detector identifies the presence of the transponder device. Depending on how you have set up your transponding reporting to the system, your system should detect the presence of the address in that transponding section.For example, if you have an ...

KB1039 How do I practically use the 400 slots available in the DCS240? How do my throttles access the slots?

The DCS240 offers 400 locomotive slots and can support up to 400 throttles.  These slots can be broken down in to standard slots and expanded slots.  There are 120 standard slots in the DCS240, these slots are accessible using any Digitrax throttle.  There are an additional 280 expanded slots available to DT402 R2 (tethered and Duplex) and later throttles.  The DCS240 identifies the throttle type being used and assigns and adjusts the slots accordingly.  Expanded capability throttles are given the Expanded slots first, leaving the standard slots available for legacy throttles.  All this is done in the background and will ...

KB188 Case Study: PUTRA Operating the Kelana Jaya Rail Line (Part 4 of 5)

The layout uses twenty-eight turnouts on the mainline and an additional eleven turnouts in the yard. Each turnout is powered by a Tortoise slow motion turnout motor. Each of the twenty-eight mainline turnouts has three dwarf signals associated with it. The aspects of the signals are shown below. The indications of the signals are: Green = Proceed Yellow = Proceed with caution Red = Stop Each signal has one head with two LEDs. There are also thirty-eight mainline block signals (red/green) that are controlled by heavy duty single pole double throw relays. This makes a total of 122 signals. Since ...

KB833 Zephyr - Dispatching Locomotive Addresses or MUs

Dispatching is a special feature incorporated in the LocoNet "language" to meet the needs of operators that wish to enforce a strict discipline in how operators gain access to locomotives during an operating session.Dispatching also lets you run MUs with basic throttles (such as the Utility Throttle series) that can't set up their own MU's and run four digit addresses on basic throttles that only have two digit capability (such as UT1 and UT2). It also lets you have newcomers run trains on the layout without giving them access to the entire operation.When you dispatch a locomotive address or MU ...

KB569 DT402 & DT402 Series Throttle Dispatching addresses or consists

Dispatching is a special feature incorporated in the LocoNet language to meet the needs of operators that wish to enforce a strict discipline in how operators gain access to locomotives during an operating session. Dispatching also lets you run consists with basic throttles that can't set up their own consists and run four digit addresses on basic throttles that only have two digit capability. It lets you have newcomers run trains on the layout without giving them access to the entire operation. When you dispatch a locomotive address or consist to your LocoNet system, you make it available to be ...

KB970 How does LocoNet Work?

LocoNet's "ethernet like" architecture seems interesting and more advanced than the systems used by other DCC manufacturers. But, at the numbers we are talking about (a few controllers and perhaps 10-20 decoders), does it really make a difference?If your system operates with a few throttles and other devices attached any of the commercially available systems will work today. But what about tomorrow? Remember when a hard-drive bigger than 32Mb seemed excessive- and remember when DOS had to change to 16bit FATs/ directories? Also, the LBA access change at 540Mb also once seemed unthinkable!!The network structure of LocoNet is very important ...

KB652 DT300 - Multiple Unit Operations

  Many prototype trains use multiple locomotives to provide the necessary power to pull or push the train. This practice is called Multiple Unit consisting, usually shortened to MU or consisting. The DT300 Throttle can provide three methods of consist control:1. The Basic Consisting method, which is not commonly used, is to program all the locomotives in a consist to the same address and run them on one throttle. In this case all the locomotives must be headed in the same direction, head to tail, head to tail, head to tail. If you use decoders that allow you to set ...

KB677 How to program a locomotive address with Zephyr

This procedure should be done on an electrically isolated programming track1. Be sure that only the locomotive you want to program is on the programming track.2. Press the PROG key on the DCS50 to enter programming mode. The DCS50 will display one of the programming modes available. Digitrax recommends the Paged Mode when you are using the programming track. If you press the PROG key repeatedly, you will cycle through the following choices:      PAGE     PHYS     dir     OPSFor example, to use Paged mode stop pressing the PROG key when the following screen appears:Each time you press the LOCO key the ...

KB424 DT400/R Tetherless Operation - Multiple Unit Operations

Consists must be assembled and broken up while the DT400/R is plugged in to LocoNet. MU operations are locked out while the DT400/R is running simplext tetherless. Once a consist is assembled, it can be operated normally using the DT400/R in tetherless mode.

KB253 How do I get started with my Zephyr?

I've recently purchased a DCS50 system to run my HO trains. Since I'm new to the hobby I'm throughly confused on what parts I need to wire my 4 x 8 foot track to my control box. How many feeder lines do I need and what size do you recommend, and how do I hook these up to my control box? What size does bus wire do I need and how do I connect all this to my system? So far, all the articles just make recommendations general terms without specifics. I have purchased 2 terminal clips but have yet ...

KB939 DCS51 (Zephyr Xtra) Operating Cheat Sheets

  Digitrax DCS51 (Zephyr Xtra) Operating Instructions by Dan Bourque v1.0 Selecting a locomotive or consist 1.         Press the “LOCO” key (display will flash) 2.         Enter the address of the locomotive or consist             - For a consist, the address will normally be the lead locomotive             - For a 3-digit locomotive number, use “0” for the first digit 3.         Press the “LOCO” key again (display will stop blinking) 4.         Move the direction selector on the throttle to either “Forward” or “Reverse” 5.         Move the speed knob until train moves   Dispatching (releasing) a locomotive or consist ...

KB952 Equipment Recommendation: Automated railroad operation

I want to sit back & watch my railroad run. Can you do that with Digitrax?The Digitrax Command Control System is designed for prototypical operation. The objective is to provide realistic operation so that the models run like the real thing. To do this you need an engineer in control of each locomotive. The starter sets are not designed for automated train control when used by themselves. To set up automated operation, you can set up the layout with detection and or transponding and use a computer to handle the automated operations.

KB21 Differences Between Simplex & Duplex Radio Operations

What is the difference between Simplex and Duplex wireless operations and what are the advantages of each?The Digitrax DT400R, DT402R and UT4R throttles operate at the 916.5Mhz radio frequency.  These throttles both use the UR91 for radio communication.  The DT402D and UT4D operate at 2.4Ghz.  They require the UR92 for radio communication. The move to Duplex is meant to improve radio operations and add radio range.  Simplex (UR91) and Duplex (UR92) can operate on the same layout without any issues or interference with each otherWith duplex radio: You’ll select and run your locomotives without plugging in.   You'll dispatch locomotives ...

KB445 Customizing the DT400 Option #2 - Throttle Default Decoder Operation

Each DT400 can be set up to operate new decoders selected by that DT400 as any decoder status code you choose. New decoders are defined as decoders that have not been selected in your system. Your DT400 is set to expect to operate mostly decoders that are 128 speed step capable, so when a new decoder is selected the DT400 defaults to that status code. If you operate mostly decoders that are only able to recognize 28 speed steps, you can change this setting.

KB451 DT402 & DT400 - Throttle Option 2 Default Decoder Status & Tetherless Operation

Throttle Option 2Throttle Default Decoder Status 128/28/14 speed steps Each DT402/DT400 can be set up to operate new decoders selected by that throttle as any decoder status code you choose. New decoders are defined as decoders that have not been selected in your system. Your throttle's default setting is to operate decoders that are 128 speed step capable, so when a new decoder is selected the throttle automaticaly assumse that all decoders selected are that 128 speed steps. If you operate mostly decoders that are only able to recognize 28 speed steps, you can change this setting.Tetherless Operation Mode Each throttle can be set up with radio ...

KB530 Intermittent Locomotive Operation - Dirty Track & Dirty Wheels

Most intermittent operation faults on all layouts, not only DCC ones, are caused by bad electrical connections and poor wheel pickups on locomotives.  Poor electrical contact causes problems with sound decoder operation in particular.  Sound decoder installations usually include a capacitor to store energy to keep the sound going when the decoder briefly loses electrical contact.   When the track is dirty or corroded, it can't transmit the electricity and DCC signal needed to run locomotives.  When the locomotive pick ups are dirty or corroded, they can't pick up the signal from the track.  Check your track cleanliness and quality of wheel pickups ...

KB851 Programming Methods-Service Mode and Operations Mode

Two Programming Methods Are Supported by Digitrax Command Stations:Service Mode Programming is done on an electrically isolated programming track. Using this mode, the command station broadcasts programming information to all decoders on the program track.  Within Service Mode programming are Paged, Direct and Physical Mode.Because these are a broadcast modes, we must isolate the decoder we want to program from the others on the layout by using a separate programming track that is connected to the command station for programming but not powered for operation of the locomotive. This mode works with all DCC decoders. This is the most commonly ...

KB119 UT4R - InfraRed Operation

Will the UT4R operate on an Infrared System also as well as a radio frequency? Yes, the UT4R & DT400R will operate on IR systems as well as radio systems.

KB422 DT400/R - Tetherless Operation - Switch Mode

The DT400/R will operate in Switch Mode while tetherless. It can operate turnouts and routes using the OPTN t & CLOC c Keys in the normal manner.

KB811 DS64 - Setting Up to Operate Slow Motion Type Turnouts

At the factory, your DS64 was set to control solenoid type turnout machines that use a single pulse output for operation. If you are using slow motion turnout machines, like the Tortoise or Switchmaster, that need a static type output to operate, you’ll need to reconfigure the DS64’s outputs before hooking up your turnouts.To set up your DS64 to operate stall motor type turnouts:1. Connect the DS64’s ‘TRKA’ and ‘TRKB’ terminals to your track. No turnouts should be connected to the DS64 at this time.2. On the DS64 press and hold the OPS button down for about 3 seconds until ...

KB396 SE8C - Can you operate more than one slow motion turnout from one output?

Q:  Can the SE8C slow motion turnout controllers operate multiple turnouts from one output? A:  No. The slow motion connection was originally intended to be used with single slow motion drives for semaphores, part of the overall design of the SE8C signal driver. Since only one semaphore is operated, the circuitry was not designed to handle heavier loads than that single drive.

KB810 DS64 - Resetting to Operate Solenoid Type Turnouts

At the factory, your DS64 was set to control solenoid type turnout machines that use a single pulse output for operation. If you are using solenoid type turnouts, you can install the DS64 “out of the box.”  If you have reconfigured your DS64 for stall motor type turnouts, the DS64 can be reconfigured back to solenoid type turnout motors.1. Connect the DS64’s ‘TRKA’ and ‘TRKB’ terminals to your track. No turnouts should be connected to the DS64 at this time.2. On the DS64 press and hold the OPS button down for about 3 seconds until the red OPS LED and ...

KB261 DT100 MU Operations

MU OPERATION Place the two units you wish to MU on the tracks controlled by the command station 1. Select the lead locomotive on the right side throttle  2. Select the engine to be added on the left side throttle 3. Make sure all the locomotives in the consist are traveling in the same physical direction. The direction lights may or may not be the same (green or red) depending on the orientation of the locomotives in the consist (head to head or tail to tail). 4. Push "mode" Button 2 times 5. The display should now show both locomotive numbers. 6. ...

KB635 DT300 - Tetherless Operation

The DT300 is “InfraReady”. The DT300R can operate tetherless on radio or “infraReady.” Both units are also provided with a cable to attach into LocoNet when required. A 9 volt battery must be used to power both the DT300 and DT300R for tetherless operation. Using DT300 as a tetherless throttle is easy:1. For Infrared operation, plug in at least one Digitrax IR receiver (UR90 or UR91) to your working LocoNet. Because infrared signals are line of sight, more than one receiver may be necessary for optimal performance in your layout room. 2. For Radio operation, plug in at least one ...

KB838 Zephyr - Function Operation Troubleshooting

If the function you want to operate does not respond, check the following:1. Is Track Status [4] on? If not press the POWER key to turn it on. 2. Did you select the correct loco? If not, select it now.3. Is the function you want to use installed in the loco? If not, you may need to install it. Most new locos have a head lamp/backup lamp installed, but most do not have any additional lights or sounds installed.4. Change the position of the Direction Control Lever and see if the lamp comes on in the other direction. If the ...

KB332 DT402 & DT400 Series Throttle Basic Operation and Quick Start Guide

These are the basic DT400 and DT402 series throttle operating instructions designed to get you “up and running” quickly and to minimize your “frustration level” as you learn to use the throttle.   Turning Track Status On and Off To run your layout you must be sure track power and track status are both ON.  Follow these steps with your DT400 or DT402 series throttle to do this. Press the "PWR" key on the bottom left side of the throttle. The words “+ON  -OFF” will come on in the display. Press the “Y +” key quickly and you should see the ...

KB774 DT400 How to Run an Analog Loco on Address “00”

'It is possible to operate one conventional DC locomotive at Address 00.  In many cases, this is the first locomotive that beginners use when they first get their command control system.  In other cases, this locomotive is one which cannot be easily converted to DCC.  Regardless, although it is possible to use your Digitrax system in this way, it is not a recommended approach.1. Place an analog locomotive (one without a decoder) on your layout.  While the analog loco is sitting still, you will hear the characteristic “singing” caused by the DCC track signal when it is applied to analog ...

KB169 PR3 Operational Modes

What are the different operational modes available in the PR3? The PR3 is the combination of two previous Digitrax devices: the PR2 decoder programmer and the MS100 LocoNet to computer interface. The PR3 can be configured through manual (control panel buttons) or automatically (software) means to perform any one of the following three operations: a) The PR3 can be configured to function as a stand alone decoder programmer. In this mode the PR3 can program the configuration variables of most DCC decoders and the sound effects of the Digitrax Sound FX sound decoders. b) The PR3 can be configured to ...

KB707 UT4 - Infrared Operation

The UT4 comes InfraReady for layouts that are equipped with one or more UR90 infrared receivers. For Infrared operation:1. Install one or more UR90 infrared receivers on your layout.  These should be connected to LocoNet and powered.  If you have UR92s and/or UR91s present on the layout, these also support infrared operation.  You will need enough infrared receivers installed on the layout so that the throttles you use can "see" the receivers since the transmission is line of sight.  You may also encounter problems in rooms where there are large windows that would interfere with the transmission.2. Install a 9 ...

KB85 Digitrax Outdoor Operation

Will Digitrax work in an outdoor setting to control LGB, Bachmann, and Aristocraft engines on a small layout, possibly in a 20 x 20 area? What starter set would you recommend to run in the area stated? I would like wireless operation. Digitrax will work in that environment, with the same warnings that are associated with all other electrically powered devices and outdoor model railroads that use track power. The command systems must be protected from moisture, the track must be clean and the stationary decoders are not weatherproof. Wireless operation can be either infrared or radio, with radio being ...

KB419 How far apart to locate boosters

Q:  Your recommendation is to have a DB150 booster at no more than 50 foot intervals. Will one booster handle all track in that 50 foot area, i.e. a passenger terminal throat with many turnouts and switches? A:  The "50 foot intervals" applies to the maximum distance which boosters can be located from each other. This is a conservative recommendation.  You should consider how much power will be consumed in a district when locating boosters around the layout. If your power district is a single track railroad stretching over hundreds of feet of linear distance, boosters should be placed at 50 ...

KB798 DS64 - How To Run A DS64 Route

How To Run a Route with DS64:1. Select the Switch Address that corresponds to the Top Address of the route you want to run.2. Issue a Closed or Thrown command depending on which you set up in the route table.Note that if you are using an actual switch address as your top address and you send the opposite closed or thrown command from that set up in the route; you will operate that switch address only and not the route.For example: If you set up Switch Address 50 as your Top Address by sending a Thrown command, you’ll need to ...

KB532 How do I wire a double crossover?

Q:  How do I wire a double crossover? Each crossover results in a reversing loop. Should I use a PM42 or AR1? This is O scale (2 rail) if that would have any bearing on your answer. A:  Without a drawing to see how things are laid out, this can only be a guess, but a couple rules do apply. The reversing sections must be longer than the longest train. And there should be only one train in the reversing section at a time. It also seems to be a good idea to keep the reversing sections away from the ...

KB709 UT4 - Consisting, MU'ing, or Multiple Unit Operations

Consisting is the action of linking more than one locomotive or power unit together to be controlled by a single locomotive address.  The UT4 is not capable of building or breaking up a consist.  This is handled by a throttle or computer program that is able to build and break up consists and then hand the consist off to the utility throttle operator.  Utility throttles are designed to be simple to use for operators on the railroad.  The UT4 CAN control a consist by selecting the address of the TOP loco in the consist.  It can also control the functions of locomotives within a consist.If ...

KB221 Locomotive Operation & Reverse Loops

If Engine "B" is operating on the main line when Engine "A" enters the main line from the auto reverse loop, will Engine "B" change direction or will Engine "B" continue its journey?With DCC, the reversing of locomotive direction takes place within the locomotive, and only when it is commanded to do so.  If you grew up in a DC model railroad world, it's easy to forget this feature of DCC.  When Engine "A" transits the reversing section and returns to the mainline, any "change" will have been to coordinate the track polarity of the DCC track current present on ...

KB423 DT400/R Tetherless Operation - Programming

Ops mode programming is the only programming method that will work while the DT400R simplex is operating as a radio throttle. If you press the PROG Key to enter programming mode, the DT400R running as tetherless will default to the Po mode (ops mode programming). The DT400R must be connected to LocoNet to use service mode programming and access any of the other programming modes available.

KB444 Customizing the DT400 Option #2 - Tetherless Operation Mode

Each DT400 can be set up with radio capability and/or infrared capability enabled, all tetherless operation disabled and power save enabled or disabled. DT400 is shipped with IR only enabled and DT400R is shipped with Radio & IR enabled

KB674 Zero Stretching-Operating a Non-DCC Equipped Locomotive with Digitrax

Digitrax Command Stations can operate one locomotive on your layout that does not have a decoder installed. This loco is called an "analog," "conventional," or "non-DCC equipped" locomotive. To operate an analog locomotive with Digitrax you will use address 00 to send commands to the locomotive.  The magic that makes this happen is called zero stretching. With Zero Stretching, an analog locomotive going forward receives an unusually long positive voltage, followed by a very short negative voltage. The much larger positive voltage ensures the locomotive moves forward. The brief negative pulse causes a low buzzing that will vary with the speed of the locomotive. This method ...

KB187 Case Study: PUTRA Computer Operation of the Kelana Jaya Rail Line Model (Part 5 of 5)

The Kelana Jaya Rail Line model layout uses WinLok 2.1 running on a PC under Windows 98 to operate the trains, turnouts, signals and to use the feedback from the block detectors for train control. This equipment was configured and programmed to PUTRA's specifications by Dr. Hans R. Tanner of DigiToys Systems. PUTRA specified the following capabilities for the control system used for the simulation: 1. Run eight trains at once in any combination of automated or manual control. 2. Define specific routings and be able to assign automatically or manually any route to any train at the time the ...

KB425 DT400/R - Tetherless Operation - Releasing a Locomotive

Two options are available for releasing tetherless operated locomotives. These options are set by DT400 Option #3. No tetherless release allowed: if the LOCO Key is pressed while the DT400/R is running in tetherless mode, the addresses selected will not be released unless the throttle is plugged in to LocoNet. This is the factory default. Tetherless release allowed: if the LOCO Key is pressed while the DT400/R is running in tetherless mode, the address selected on that side of the throttle will be released immediately and that throttle will become inactive. To re-select this loco address plug your DT400/R in ...

KB66 SE8C - Local Switch Inputs for Turnout Operation

SW01 to SW08 are inputs that allow a local switch mounted on the layout to operate the slow motion turnout machine. For example, SW01 when connected to the +VE sensor common (Pin 2 in figure) will reverse the voltages on SMTM1A and SMTM1B to change the position of turnout 1. SW02 controls local turnout 2 , etc. For each connection to +VE sensor common the slow motion turnout machine swaps direction and a Switch message is sent to LocoNet to report the new position of the turnout. This local control can be disconnected by setting OpSw 15 to closed, in ...

KB199 UT4 - Battery Storage

My club uses UT4R radio throttles. At the end of the session they ask that the battery be reversed in the throttle housing to "extend battery life". This effectively reverses the polarity of the battery in the throttle. Is this step necessary? Is there any drain on the battery when the throttle is not in use? If there is a drain, should the battery then be removed for storage? So my question is: How should you store a UT4R so as not to drain the battery when the throttle is not being used? The throttle batteries will indeed drain if ...

KB705 Can I operate LGB LOCOs (with LGB decoders) on a Digitrax system?

The LGB MTS (Multi-Train System) is DCC based, so a system such as Digitrax Super Chief 8 Amp and a high current power supply such as the Digitrax PS2012 (rated at 20 amps) will work successfully.However, the LGB system is not a pure DCC system and there are reports of problems when Digitrax units are used to program LGB decoders, especially the sound decoders.  The latest LGB MTS decoders (Generation III) will operate with NMRA DCC systems, however some of the sounds and other functions may not work.  Some users have reported creating a "hybrid" system, but we do not recommend that ...

KB429 DT400/R Tetherless Operation - Overview

DT400R is a radio equipped throttle. To use your DT400R as a radio throttle, you will need to install a radio receiver on your layout. All DT400s are “InfraReady.” This means that your DT400 comes with IR LEDs that will send infrared signals to the layout. To use this InfraReady capability, you just need to install one or more infrared receivers on your layout. A 9 volt battery must be used to power the DT400/R for tetherless operation. Using DT400/R as a tetherless throttle is easy: 1. For Infrared operation, plug in at least one Digitrax IR receiver (UR90 or ...

KB420 DT400 series Tetherless Operation - Control Lock

While the DT400 series throttle is being used tetherless, there are occasions when you may want to disable the throttle's controls to prevent accidental commands being sent to the railroad. For example, your train is in a siding waiting for another train to pass. You put your throttle in your pocket and go take a break. By locking the throttle controls, you will not be able to accidentally start your train if you bump your throttle knob or press the Y + Key . To lock the controls on your DT400 1. Press both the Y + and the N ...

KB599 Can AR1 be used to set up automatic back and forth operation?

Q: I am building a new DCC layout that will include a logging spur that is simply a single long piece of track with no loop. I want to have a train go back and forth on this track which automatically reverses when it gets to each end. While the AR1 was designed for reversing loops, can it be wired to simply reverse a train on a straight piece of track? A:  Not in the way that you intend. One of the interesting problems with DCC is that we often still think in terms of DC, where the track polarity ...

KB819 Zephyr - Customizing Operation with Option Switches

The DCS50 is set up at the factory to run right "out of the box", but the DCS50 does have several operational options that you can use to customize the perfomance of your railroad.  It should be noted that: Most customers never have any need to change these options.Changing DCS50 Option Switches1. See the DCS50 Option Switch Table that follows to decide which option switches you want to change.2. Press the PROG key. The display shows the last decoder programming mode used by the DCS50.3. Press the SWITCH key. The display shows the last switch used by the DCS50 and ...

KB736 DT402 & DT400 Series Throttle - Stealing and operating a stolen loco address

Stealing is  also known as Forcing An Address Selection or SharingIf you try to select a loco address that is already selected on another throttle the DT400 will display “Steal?=Y” in the text area. This is a safety interlock to prevent operators from taking control of locos that are already selected on other throttles. Occasionally it is necessary to override this interlock to gain control of a loco that is “lost” for whatever reason. This override is called stealing & can result in having a single loco address selected on two different throttles at the same time.To steal an address ...

KB55 RR&Co Settings for BDL168 & BXP88 Operation

Railroad & Co. is a suite of computer programs for both digitally and conventionally controlled model railroads. The BDL168 needs to have several Option Switches changed for proper operation with Railroad & Co.'s Train Controller program. Our recommendations are based upon experience with earlier versions of the program: Suggested BDL168 Settings for Railroad & Co. (from European users): OpSw9 = Closed (No message sent if un-powered) OpSw36 = Closed (Ignore GPON) OpSw37 = Closed (Long delays for sensors) OpSw38 = Closed (Extra long delay for sensors) OpSw39 = Closed (Verbose mode enabled) OpSw43 = Closed (Filter for transponding disabled) OpSw45 ...

KB777 DT402 & DT400 Series Throttle Basic Operation

1. Plug the DT402 & DT400 series throttle into any functioning Digitrax LocoNet System or other LocoNet compatible system and you are ready to go! You can use any LocoNet jack on your system.2. First, you will see the DT402 or DT400 version number screen: This screen shows the throttle's software version number. It is displayed for a few seconds each time you power on the throttle.3. Next you will see the power indicator screen: This screen indicates the power available to the throttle. When you are plugged in to LocoNet, this value will be between 9 & 15 volts. When you ...

KB173 PR3 - Operating as a LocoNet Terminator

Just wondering if i can get clarification regarding using the PR3 as a standalone Loconet Terminator. The "LocoNet termination" mode of the PR3 allows the unit to connect to other modules without needing a command station, when there is no requirement for DCC track packets. In this mode you can interface to a PC and add units like DS64's with control of turnouts and detection (BDL168) and signals (SE8) without needing to run DCC track control or decoders. Running off e.g. JMRI or RR+Co is a good and intended usage.

KB186 Stationary or Under-layout Operation

The SFX004 can be used in a stand alone configuration as well. In these situations just connect pins 9 and 10 to the track and address the device normally.

KB421 DT400 Series Tetherless Operation - Fast Clock

When using the fast clock option, the DT400 series will keep track of and display fast time based on the last synchronized system fast time when the DT400 was connected to LocoNet. If the fast time is edited by another throttle connected to LocoNet, the DT400/R will not see this change until it is plugged into LocoNet at which time its display will be updated.

KB428 DT400/R - Tetherless Operation, Fast Clock Caution

Fast clock caution: If you use power save mode, the DT400/R’s local fast clock copy will deviate from the LocoNet system clock. The fast clock will re-synchronize with your LocoNet system fast clock when it is plugged in again.

KB924 CV09 - SuperSonic Quiet Decoder Operation

The SuperSonic decoder feature allows you to adjust the PWM (pulse width modulation) frequency of your decoder to reduce the humming noise that is characteristic of the DCC signal.Digitrax decoders that have this feature are shipped with the value set at 000/x00 or maximum PWM.  To change this value, you can set any value from 000/x00 (max) to 255/xFF (min).  Entering a value of "255" will turn this feature off.Use of this feature will make the locomotive run more quietly but will reduce the torque generated by the motor.  Digitrax torque compensation can be used to compensate for this effect.

KB457 DT402 & DT400 Switch Mode - Turnout & Switch Operation

  What is Sw (Switch) Mode? Switch mode is used by throttles for sending commands to accessory decoders and for changing option switches in your LocoNet system. The most common use of switch mode is for operating turnouts.Switches are either thrown or closed.To change the position of a switch or turnout: 1. Press the SWCH key to enter switch mode. When you enter Switch mode, the throttle knobs & direction keys continue to control the loco addresses running on the throttle. Loco speed is displayed on the bar graph and loco direction is displayed on the direction indicators for each ...

KB575 Multiple Unit or Consist Operations - Overview

Digitrax Command Stations offer three methods of multiple unit (MU) or consist control:1. Basic Consisting2. Advanced Consisting3. Universal Consisting (the Digitrax preferred method) By definition, Digitrax always adds loco addresses to the “TOP” loco address in a consist.   The “TOP” loco is special, in that it is the address that receives the speed & direction commands for the entire consist.   All non TOP loco addresses added to the consist are controlled by commands sent to the “TOP” loco.   The TOP locomotive does not have to be a physical loco on the track, it can be a phantom. ...

KB247 UT4D Throttle Operating Cheat Sheet

  Digitrax UT4D Throttle Operating Instructions by Dan Bourque   v1.0 Selecting a locomotive or consist 1.         Dial the 4-digit locomotive address into the “LOCO ADDRESS” dials             - For a consist, the address will normally be the lead locomotive             - For a 3-digit locomotive number, use “0” for the first digit 2.         Press the “SEL” key, the ST light on the throttle should flash green 3.         Move the direction selector on the throttle to either “R” or “F” 4.         Move the speed knob until train moves 5.         For headlight, press the “F0” key (“F3” will ...

KB45 Duplex Radio, Simplex Radio & Infrared-How do they work together?

The ability of a variety Digitrax throttles to work together on layout equipped with a variety of wireless technologies is part of the beauty of LocoNet.  With LocoNet, it is simple to add components to the system and have all of them work together. Digitrax infrared throttles will operate on any layout equipped with UR90 infrared receivers, UR91 simplex receivers and/or UR92 duplex transceivers.  All of these panels are equipped with infrared receivers.  All current model Digitrax throttles have infrared emitters that will work wirelessly with any panel that has an infrared receiver.  All current Digitrax throttles can also be used ...

KB563 DT402 & DT400 - Multiple Unit Operation Consisting

To run two or more locomotives together as a multiple unit lash up or consist controlled by a single locomotive address: Place the two or more units you wish to MU on the track. 1. Select the TOP loco (the one that will control the consist) on the right hand throttle knob. 2. Select the loco to be added to the MU on the left hand throttle knob. 3. Make sure all the locos in the consist are traveling in the same physical direction on the track (both going to the left or to the right) 4. Press the "MU" key 5. Press the "+" key 6. ...

KB244 DCS50 (Zephyr) Operating Cheat Sheets

  Digitrax DCS50 (Zephyr) Operating Instructions by Dan Bourque   v1.0 Selecting a locomotive or consist 1.         Press the “LOCO” key (display will flash) 2.         Enter the address of the locomotive or consist - For a consist, the address will normally be the lead locomotive             - For a 3-digit locomotive number, use “0” for the first digit 3.         Press the “LOCO” key again (display will stop blinking) 4.         Move the direction selector on the throttle to either “Forward” or “Reverse” 5.         Move the speed knob until train moves   Dispatching (releasing) a locomotive or consist 1.         ...

KB837 Zephyr Xtra and Zephyr - Multiple Unit Locomotive Operations

  MU (Multiple Unit) OperationsIt is not uncommon to see two, three or even four diesel locos pulling in consist at the front of a train. Sometimes, there is a locomotive added in the middle of the train or at the end of the train to give “helper service” to the head end locomotives. This is called Multiple Unit Operation or MU operation. With DCC, each locomotive is separately controlled. But in the case of MU'ing we would like to have more than one locomotive address controlled by a single throttle to simplify MU operation.Your DCS50 uses universal consisting to ...

KB540 How do I turn off speed stabilization (Back EMF)?

Q:  Since the back emf torque compensation feature make consisting a real headache, I would like to know how to switch that feature off. Prototype loco's don't have such a thing so that slowing on a grade isn't really a bad thing in a model, either. A:  You can turn turn the speed stabilization on or off with CV57.  The CV value range for CV57 is 0-15.  If CV57 = 0, speed stabilization is OFF.  If CV57 = 15, speed stabilization is fully on.  All values in between let you scale how much speed stabilization you will use with each ...

KB133 How do I mount the 44 pin edge connector boards?

My question is: How do I mount the PM42? Do I need a special housing in order to mount it under table? It appears to me that mounting it flush against a surface would prevent, or make it extremely difficult, to attach the 44-pin connector. Digitrax manufactures three devices which have a 44-pin connector. These are the BDL168 (and its predecessor the BDL16), the SE8C and the PM42 (and its predecessor, the PM4). These best approach to mounting these devices is to screw the connector directly to the wiring panel board. Drill mounting holes in the end of the 44-pin ...

KB47 BDL168 - How to Change the Option Switches

How to read back and change BDL168 Option Switches (OpSw): 1. Power up your BDL168 and connect it to LocoNet. 2. Connect a DT series or UT1, UT2 Digitrax throttle to one of the the BDL168's LocoNet connectors. NOTE: The UT4 will not work as its design is different for the original UT series throttles.3. Press the switch behind the red option LED for about 1 second, then release it. The red option and green ID LEDs will flash alternately to let you know that you are in option switch setup mode. 4. Go into SWITCH mode on your throttle. ...

KB617 Am planning a 4 district layout with a Super Chief set. how to handle circuit breakers

Am planning a 4 district layout with a Super Chief set. Can I serve all 4 districts with it using circuit breakers for each district? If not what do I need?In this case, the PM42 quad power manager can be used to give you circuit breakers in each of the 4 sub-districts.

KB660 DT300 - How To Select Loco Addresses

Each DCC decoder that is installed in a locomotive is assigned a unique address. To select a locomotive and run it on either throttle, you must know the address assigned to the decoder. Digitrax decoders are set up at the factory with the “default” digital address of 03. This means that when you take a Digitrax decoder out of the package and install it in your loco, you can select address 03 on your throttle and run the decoder. The first Configuration Variable (CV) programmed by most DCC users is the decoder’s address since it is not very useful to ...

KB461 DT400 & DT402 - Programming CVs other than address

In addition to the locomotive address, there are different Configuration Variables (CV's) that have been defined to handle many characteristics you might want to use for your locomotives. These include operational characteristics such as acceleration, headlight functions and others. The manual for each decoder type has a complete listing of CVs that are available in specific decoders, what they do and the suggested values for each CV. Simpler decoders have few CVs while advanced decoders may have many different CVs 1. Place the decoder equipped locomotive you want to program on the programming track If you are using operations mode ...

KB773 DT402 & DT400 Series Throttles How to Select & Run a DCC Equipped Loco

How to Select and Run a DCC Locomotive Using a DT402 or DT400 Series Throttle 1. Activate the throttle's left throttle knob “L” by turning it a 1/4 turn in either direction or by clicking the throttle knob once. The left side address will begin flashing. If nothing is selected on this throttle it will flash “SEL”.2. Press the LOCO Key. The left side of the display will begin flashing. The illustration above shows the LCD display just after you press the LOCO Key to select an address on the L Throttle when nothing has been selected on that throttle before and ...

KB12 Programming CVs Other Than Addresses with DT402

There are 1024 different CVs that have been defined to handle many characteristics you might want to use for your locomotives. Your decoder manual has a complete listing of CVs that are available in specific decoders, what they do and suggested values for each CV. 1. Place the decoder equipped locomotive you want to program on the programming track. If you are using operations mode programming, the loco you want to program can be anywhere on the layout but it must have a decoder that is capable of ops mode programming installed. 2. Enter Program Mode by pressing the PROG ...

KB314 RoHS / Lead Free Production Q&A

Q: What is RoHS? A: The RoHS Directive stands for "the restriction of the use of certain hazardous substances in electrical and electronic equipment". This Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants. Q: When did the directive become effective in the EU? A: July 1, 2006 Q: How does this affect products shipped to countries outside the EU? A: The United States and Canada have not yet instituted RoHS as of January ...

KB993 UT4 Throttle Operating Cheat Sheet

  Digitrax UT4 Throttle Operating Instructions by Dan Bourque     Selecting a locomotive or consist 1.         Dial the 4-digit locomotive address into the “LOCO ADDRESS” dials             - For a consist, the address will normally be the lead locomotive             - For a 3-digit locomotive number, use “0” for the first digit 2.         Plug the throttle into any receptacle on the layout fascia (e.g. Digitrax UP5) 3.         Press the “SEL” key, the ST light on the throttle should turn green 4.         Move the direction selector on the throttle to either “R” or “F” 5.         Move the ...

KB1048 Digitrax Command Control - The Future Is Now (2016 version)

Digitrax Complete Train Control By Zana & A.J. Ireland Digitrax Complete Train Control makes reliable, realistic train operation and simplified layout wiring a reality. Digital Command Control is incorporated within the Digitrax system to let you control multiple trains independently on the same section of track without blocking. In the real world, engineers control the speed and direction of real trains. Engines operate under their own power independent of the track. Each engine has its own motion characteristics like how fast it speeds up (acceleration) and how long it takes to slow down (deceleration). A locomotive's performance is influenced by ...

KB236 CV29 - 2-digit or 4-digit Addressing

  CV29 is assigned a single value which chooses a combination of specific effects: 1. Speed step control. 2. Speed table On or Off. 3. Analog mode conversion On or Off. 4. Normal Direction of Travel (NDOT). 5. 2 digit addressing or 4 digit addressing. 2-digit or 4-digit Addressing The decoder's address is the identification number programmed into specific decoder that lets that decoder recognize commands sent to it by the command station. Once you program the decoder's address, it will be remembered in the decoder until you re-program it. All Digitrax current production decoders can be set up with ...

KB869 Troubleshooting Guide for Digitrax Command Station or Booster Problems

Before sending your Digitrax Command Station or Booster in for repair try these simple steps to see if you can “bring it back from the dead” and save a possible trip to the repair shop.1. Nothing is respondingIf there are NO LEDs lit on the front panel of the Command Station or Booster: Check the power supply to the unit to make sure that it has not been knocked loose in the power socket and that the socket is powered. Check the connections from the power supply to Track A and Track B connections on the front of the unit ...

KB99 Shutting Down & Resuming with the DB150

Shutting Down the System When you are finished with your sessionDispatching All Locomotive Addresses Some users prefer to “dispatch” or release all addresses active in their system before shutting down. This can prevent unexpected results when you power up the layout again. 1. Turn track power off: Press the PWR Key followed by the N - Key , the Track Power Indicator on the DT400 and the Track Status Indicator on your command station will go off. 2. Move the DB150 command station’s “MODE” switch to the “SLEEP” position. 3. Turn off the power supply to the system. Leaving the ...

KB404 UR90 Infrared Receiver Frequently Asked Questions

How Many UR90 Infrared receivers will I need?One UR90 should provide complete coverage if your room is typical, with a hard surface floor and finished walls and ceiling. However, several things can cause the need for additional UR90s, such as: larger room, odd shaped room, acoustical ceiling, carpeted floors, or book shelves or other things on the walls that can interfere with the infrared signal. How many more you'll need depends on how many of these "impediments" are in your layout room. This Infrared signal should be considered to be line-of-sight, but the IR signal does reflect off of other objects, thus the concern ...

KB986 Digital Command Control: The Wave of the Future-Early Version

By Zana & A.J. IrelandThis clinic is titled Digital Command Control: The Wave of the Future. Recently, I was asked the question: "DCC has arrived and is the technology of today, everybody's using it so, why don't you change the title of your clinic?" My answer is that digital command control is still evolving rapidly. Today's digital command control is moving beyond the basic NMRA DCC Standards and RPs to encompass many new technologies that will compliment and enhance the basic things we can do with the track format defined by the NMRA. It's an exciting time for model railroaders ...

KB989 Digital Command Control: The Wave of the Future-Later Version

By Zana & A.J. IrelandThis clinic is titled Digital Command Control: The Wave of the Future. Recently, I was asked the question: "DCC has arrived and is the technology of today, everybody's using it so, why don't you change the title of your clinic?" My answer is that digital command control is still evolving rapidly. Today's digital command control is moving beyond the basic NMRA DCC Standards and RPs to encompass many new technologies that will compliment and enhance the basic things we can do with the track format defined by the NMRA. It's an exciting time for model railroaders ...

KB518 Locomotive Speed Matching

Q:  I am trying to setup 4 Kato locomotives 3 SD-70MACs and 1 C-44-9, all with DN 163K1B decoders.  I am using the loadable speed tables V in the programing manual that came with my Super Chief for a starting point. I have spent a few hours with limited success. Do have any suggestions that may help simplify this process? A:  Because the decoders and command control system are digital, the commands sent from the command station based on the CV settings in each locomotive are always the same. It is the locomotive mechanisms that are different. Even with three "identical" locomotives from ...

KB211 History of Model Train Control Systems-Pre DCC

  The first steam locomotive to pull a train appeared in 1804, although there were examples of vehicles operating on rails even earlier than that.  As railroad technology captured the imagination of investors, it also captured the eye of the general public.  It was inevitable that someone would make a child’s toy of this wonderful thing.  Models of trains would evolve like any other technology.  As railroad technology advanced, so did the quality of model trains.  What started with crude blocks of wood evolved into cast iron “floor toys”; these crude trains were meant to be pushed along on the ...

KB458 DT402 & DT400 - Read Back CVs

The DT402 & DT400 can program and readback CVs with the DCS100 or DCS200 (Super Chief) or the DCS51 or DCS50 (Zephyr). You must use the programming track for this unless you are using Ops Mode with transponding installed to allow for Ops Mode readback.  Infrared and simplex radio throttles must be plugged in to LocoNet to read back CVs & their values.  Duplex radio throttles do not have to be plugged in for reading back CVs.Systems with a DB150 command station (Super Empire Builder) are not able to read back CV Values programmed into decoders. To read back CV values: 1. Place the decoder ...

KB210 Modular Track Systems

An important series of developments in model railroading have taken place that makes it much easier to enter the hobby and enjoy it right away.  DCC is part of that process since it makes it easier to handle the train operation aspects of the hobby.  Other improvements have been the ready availability of correctly decorated locomotives and cars, scenery systems such, and, most importantly of all, advanced track systems.  Where it once required hours to get your model railroad’s track in proper operating form, the new modular track systems have greatly simplified things.  Everything just clicks together.These modular track systems ...

KB915 Simplex Radio Safety Selection-Why Do I Have To Plug In To Select A Loco?

Digitrax's “safety selection” is an important operational safety feature. Digitrax chose not to allow one way address selection to prevent multiple operators from being able to select and send commands to the same addresses at the same time. Having multiple operators sending commands to the same address can result in serious problems in an operating session because locos can appear to be out of control. Simplex radio throttles like the DT402/R, DT400/R, DT300/R, UT4/R and similar throttles operate as one-way (simplex) infrared or radio transmitters. The DT402, DT400/R, DT300/R, UT4/R must be plugged into LocoNet to select an available locomotive address to run on ...

KB878 14, 28 or 128 Speed Steps-Why?

This article was originally posted on this site in 2006, but the source material dates back much further than that, probably back to the early 1990's, when DCC was an emerging control system. The article discusses non-sound mobile decoder programming operations. Many of the issues discussed in this article are less relevant when using recently produced decoders, but this text still does cover some questions which may be raised when you are using mobile decoders which were manufactured by other companies. These decoders will operate in the Digitrax environment, but you may need to make some adjustments.The earliest Digitrax mobile ...

KB311 Diesel Notches

  Could you please explain what the notch rate does- is there a range for this? Is there somewhere with more detailed explanations of the various CV's- such what what the air drier or compressor rate might be? Diesel locomotives are operated by "notches", which are the rate at which the locomotive's diesel power is being applied. Traditionally, these are called "Run 1" to "Run 8". At Run 1, the locomotive generator becomes active but the locomotive prime mover (the diesel engine) does not increase in speed. With Run 2 to Run 8, the locomotive's engine speed (and thus the ...

KB405 UR91 Simplex Radio Receiver Frequently Asked Questions

Simplex Radio Coverage One UR91 should provide full coverage for a typical model railroad under most circumstances. Simplex Radio reception is affected by metal objects between the throttle and UR91 simplex receiver, or large metal objects adjacent to the receiver; a furnace is one example of such an object. Such objects cause a second reflected signal, impairing the radio throttle signal's ability to reach the UR91. In this case, the receiver gets the signal directly from the throttle, then another signal right on top of it from the reflection. Moving the UR91 to another location may solve this problem, or you ...

KB870 Troubleshooting Guide for Digitrax Mobile Decoders

Before sending your Digitrax mobile decoder in for repair try these troubleshooting steps to see if you can “bring it back from the dead” and save a trip to the shop and possible repair charge. As with troubleshooting anything, begin checking what could be wrong methodically. Write down your observations as you work through the list to solve the problem.The most common "repair" problem we see in our repair department is decoders that are programmed incorrectly.Many decoders we receive for repair have been programmed with CV values that cause them to seem to have a problem. The good news-bad news ...

KB509 Narrow Gauge Decoder Selection

Q:  As an HOn3 advocate and new to DCC with early PFM engines (2-6-0 & 2-8-0 motors in tender and some smaller ones) what would be the suggested decoder (am not sure am identifying the part correctly) that would be used in these engines? All I have seen so far identifies items used in H0 standard gauge. A:  Digitrax has many happy Narrow Gauge customers.  You'll need to consider three things to join their ranks.1.  The physical size of the decoder, because narrow gauge engines are smaller than Standard Gauge locomotives. Since your space is limited, using smaller decoders is the solution. Digitrax ...

KB129 Recommendation For Small Starter Layout

I have a 4x8 H0 scale layout.  I'm 13 years old and REALLY thinking about switching to DCC, I need to know really fast because I want to ask my parents to get it for Christmas.You wouldn't know by looking at those who edit the Tech Support Depot, but there actually was a time when we too were thirteen, and just starting out in model railroading.  In many ways, we still are thirteen years old; we just can't move as fast.  Consider this photograph from our youth: This little bit of ancient model railroad history dates back to the 1950's, ...

KB799 DS64 - Setting Up Routes With DS64

How To Set Up Routes Using Your DS64NOTE:  During this procedure the DS64 must be connected to an active LocoNet with an active command station.1. Press and hold down the STAT button on your DS64 until the green LED begins to blink quickly. You are now ready to set up a Route.2. To program the DS64 Route Number, use your DCC throttle in Switch mode to select a Switch Address from 1 through 8 and issue a Closed or Thrown command. This lets the DS64 know which of the 8 available routes you are setting up. This is NOT the ...

KB519 Decoder Lock CV15 & CV16

Decoder Lock lets you use more than one decoder in a locomotive and be able to program their CVs separately.  This is a manufacturer specific CV.  The instructions provided here work for Digitrax decoders.  If you are using decoders from another manufacturer, please consult your decoder instructions for how this feature works with the decoder you have installed. For example, if you use a mobile decoder and a sound decoder together in your locomotive, you can use the same mobile decoder address during operation and when programming you can unlock only the one you want to program. Since all decoders with the ...

KB1031 Duplex Troubleshooting

  Digitrax Duplex Wireless Functional diagnosis and debug process:   Duplex Background:  The Digitrax Duplex radio system is a two-way RF radio link connecting wireless throttles (DT402D & UT4D) via a UR92 onto LocoNet.  It operates on one of 16 user-selected channels in the 2.4GHz Wi-Fi frequency band.  FCC rules requires that all WI FI devices including the RF24 Duplex transceivers (part of Digitrax Duplex throttles and the UR92) operate co-cooperatively in this 2.4GHz band and have to accept whatever wirelessenvironment is present.  This means that there is no guarantee that Digitrax Duplex will work in all situations or that it will ...

KB527 DS54 - Program Enable Link

Q:  What is the purpose of the Program Enable Link? A:  The CV Program Enable Link is used to program the DS54. The link (two pins) must be in the open position (one pin uncovered) for normal DS54 operation. The link (two pins) must be in the closed position (both pins shorted by the shorting block) during the programming of the DS54. Warning: The DS54 will behave erratically if the link is closed during normal operation.

KB631 DT300 - Edit Fast Clock Time, Rate And Alarm

  Note: DT300 radio or infrared versions must be plugged in to LocoNet to edit the fast clock settings.1. From Lo (Loco) mode, press the MODE key to change to Sw (Switch) mode.2. Press the FN/F0 key to change from Sw (Switch) mode to E (Editor) mode.3. The mode indicator in the center of the bottom row of the display will show Ec (Edit Clock Mode) and the text area will show the current system time in either a 12 or 24 hour format.4. Use the L and R THROTTLE knobs to dial up the desired start time. Use the ...

KB128 Digitrax Mobile Decoders & DC Power

I am getting a DH165LO decoder and a SFX004 Soundbug. Will these function on standard DC power? Yes. The DH165 series has "analog mode conversion"; the default setting is for operation in both DC and DCC environments. There are some that do not want this feature, and it can be disabled by setting CV29. The SFX004 also operates in a DC environment, and the analog mode conversion can be turned off via CV29. If so, how? Early on, Digitrax recognized that locomotives are sometimes operated in DC environments, and the conversion feature was built into the firmware. In practice, those ...

KB933 Motor Isolation Protection FX & FX3 Decoders

FX3 decoders have motor isolation protection. If the decoder senses that the motor is not isolated, it will not run the motor. In this case, you will be able to control the loco’s functions but the motor will not work.FX decoders will blink the loco's lights when power is first applied to the decoder to warn you of a short circuit in your installation. If you see the lights blinking, immediately remove the loco from the track, locate the short circuit and correct the problem before proceeding. Do not leave the loco on the track with blinking lights because eventually, ...

KB27 DT402 - Controlling Functions

The DT402 Throttle will control up to 29 functions in walkaround and radio modes. When operating in IR Mode the DT402 series throttles will control up to 9 functions (F0-F8). The numeric keypad is always active in the normal Fn operation mode. The functions that are currently on for the active loco will be displayed on the top line of the DT402 display. The following figure shows an example of how the display looks when functions 0 and 1 are turned on for loco 1652 on the R Throttle. Controlling Functions F0-F12 1. Determine which throttle you want to control ...

KB601 No Track Status Light - Things Aren't Working

One of the basic problems encountered with command control systems is when things simply are not working.  Period.  Even after vigorous exhortation on your part, and perhaps even some enthusiastic train table banging, nothing is running.  At this point, it is time to gather your wits and your patience for a debugging session.   The first step to determining how to proceed is to determine if the problem with the electronics or with the layout?  The tendency is to blame the electronics, after all it is a black box.  But don't jump to conclusions so quickly! Be patient and follow the ...

KB609 Automatic Reversing Tips

In earlier generations of model railroading, the reverse loop (reversing section) was the bane of many model railroaders. As the rails of a track come back upon themselves, an electrical short circuit is created. In the analog control world, the solution is to use toggle switches and special wiring to allow the locomotive to move on to the next block. Electromechanical solutions relying on relays and track detectors can also be used to automate reversing on an analog layout. The wye is another example of a reversing section on a layout. One of the advantages of digital command control is ...

KB947 The Difference Among DCC Systems & DCC Companies

In response to questions about the differences among the DCC systems that are currently available from different companies, I offer the following comments & observations. You may have heard that all the systems are pretty much the same or you may have seen “comparison” charts in various DCC companies’ literature, in magazines or “analysis” on the Internet by “impartial observers.” Unfortunately, it is almost impossible to break down the system and company differences on a simple chart & the people who write the “impartial analysis” are usually not really impartial. As you read these comments, please keep in mind that ...

KB336 Which Decoder should I use?

I have many many loco's. How do I determine which mobile decoder to select for each one? First, modelers with many locomotives often become bewildered at the prospect of converting all of their locomotives to DCC. Take it one step at a time. Consider that you are not operating all of those locomotives at the same time; start by gradually converting your locomotives, beginning with your favorites. Digitrax maintains a list of suggested decoders for specific locomotives on our website.  The Digitrax Decoder Selector can be found here: http://www.digitrax.com/products/engine-matrix/decoderJust because your particular locomotive is not listed does not mean that ...

KB639 PR1- FX Lighting Effects Setup

When you click on the "FX-Setup" button a second menu screen appears which contains the special light effects for the FX decoder. If the decoder you are programming is not capable of FX effects, this section will not apply to your situation.On this screen we have access to F0 Forward Light, F0 Reverse Light, F1, F2, F3 & F4. The programming directions and choices are the same for each function. The pull down field to the right of this shows you which effect is assigned to that particular function. The following is a list of choices: No effect, normal function ...

KB902 Scaleable Speed Stabilization (Back EMF) in Digitrax Decoders

Speed stabilization is a feature that causes the decoder to run the locomotive at a somewhat constant speed according to the throttle setting. This means that if you set your throttle to 21% of total speed, the decoder will force the motor in the locomotive to maintain a constant speed at that level no matter what the track gradient or the load on the locomotive. The SD9 is an example of a US prototype that employed a load compensating type of control technology. Many modern European locomotive prototypes use some form of load compensation of the prime-mover in response to speed ...

KB130 Using PM42 to correct shorts caused by thrown switches

Q: If my layout is experiencing short because of a thrown switch, how can you reset the switch using DCC? Many Digitrax operators use the PM42 Power Manager, which provides protection to four power sub-districts. One segment of the PM42 is used to control track switch power, with the balance being used for train power. When the inevitable happens and a train runs into a thrown switch, resulting in a short, the PM42 shuts down the track power in that segment, while the track switch power is maintained, allowing you to throw the offending switch. Because the PM42 isolates only ...

KB945 What does the NMRA Conformance Seal mean?

It means just what it says. "This Product Conforms To All Applicable NMRA Standards." An NMRA Conformance Seal is NOT an endorsement by the NMRA. It is NOT a guarantee by the NMRA or by the manufacturer. It is merely a statement that a particular product conforms to a particular test set up and administered by NMRA volunteers to assess whether, in their opinion, the product conforms to a particular NMRA Standard. Interpretations of this statement vary widely depending on whom you ask for clarification.The Real Issue is InteroperabilityInteroperability means that you don’t have to worry about a single source ...

KB379 Super Empire Builder Power Requirements

The answer to this question applies to all Empire Builder sets including Super Empire Builder XtraQ:  I have just purchased a Super Empire Builder set. My expectations are for it to operate an N-Scale switching layout right now with future expansion to a larger N-Scale layout. I am a little confused as to which power supply I would need at this time. I am reading about power supplies and inline fuses, all of which is a little overwhelming to me as I am getting back into the hobby. Can you recommend which power supply will be better for me as ...

KB33 Programming Soundtraxx Tsunami Decoders with Digitrax Zephyr

Zephyr Xtra (DCS51) and Zephyr (DCS50) systems can program Soundtraxx Tsunami decoders using Blast Mode Programming on the Mainline.  Blast Mode Programming will program EVERYTHING sitting on the main line track so, you MUST remove everything from the track that you are not programming or use an isolated piece of track connected to Rail A & B. NOTE: Track power must be ON during Blast Mode Programming.  Blast Mode programming will work with all sound decoders not just Tsunami. You will not be able to read back CVs using Blast Mode Programming.  To use Blast Mode Programming with Zephyr, close ...

KB283 High Frequency Filters?

Q: I read in the February 2008 "Scale Rails" on page 11 that I need to add some "High Frequency Filter" gizmos on my layout to make my trains run properly. I have been using Digitrax equipment for 12 years, do I need to make these changes? A: We do not feel that this is necessary. With modern, well designed decoders, almost any combination of transmission-line ringing and other mismatch effects described in this article are completely filtered and ignored by the decoder. This is a superior solution rather than trying to design filters for unpredictable limiting cases of wiring ...

KB464 DT402 & DT400 - Programming Mobile Decoder Addresses

  Duplex Radio Throttle do not need to be plugged in to LocoNet to Program Decoders.  Simplex Radio & Infrared throttles must be plugged in to LocoNet to program CVs on the programming track. Ops Mode Programming can be done without plugging radio throttles in to LocoNet. IR throttles must be plugged in for Ops Mode Programming. 1. Be sure that only the loco you want to program is on the programming track. If you are using operations mode programming, the loco you want to program can be anywhere on the layout but it must have a decoder that is ...

KB60 BDL168 - Connecting two RX4's

The BDL168 manual states that 2 RX4's can be connected but it only shows how to connect one of them on Aux 2. How is the second RX4 connected? The RX4 is a 4 Zone Transponding Receiver Add-on for BDL16 series occupancy detectors. Each RX4 is made up of 4 RX1 sensors, a ribbon cable and a connector that lets you plug the unit into a BDL16-series detector. The earlier BDL16 and BDL162 occupancy detectors had the capacity for hosting one RX4. BDL16 & BDL162 boards are labeled with AUX1 & AUX2. Only the AUX2 connection should be used for ...

KB366 Some Thoughts on Decoder Installations

There was a time when every mobile decoder installation was a custom installation. In those early days, we were just feeling our way along, trying to find ways to make the existing supply of decoders fit into locomotives which had been designed in a different era. Fortunately, things have changed along the way, and in many cases, the Digitrax Decoder Selection Guide will list your locomotive. But many locomotives are not listed because they are too new or are too generic for a special listing. So, from time to time, you will have to "wing it" just a bit to ...

KB741 DT402 & DT400 Series Numeric Keypad

There is a numeric keypad on the DT402/DT400 throttle.  The numeric keys on the keypad are primarily related to the throttle mode shown in the LCD’s mode indicator area, but can be used for numeric entry and function control in other modes. For example, when the command station is in the Function Mode Fn, the numeric keys are used for function control. When the command station is in the Locomotive Mode,Lo, the numeric keys are used to enter loco addresses. When the command station is in the Switch Mode is Sw, the numeric keys are used to enter switch addresses.In ...

KB72 Cajon Pass, Salt Lake & Santa Fe RR

I am putting the finishing touches on my 10 x 20 foot H0 railroad. It is a copy of the Cajon Pass, Salt Lake & Santa Fe RR by John Armstrong (#86 in the 101 Track Plans by Linn Westcott) [Kalmbach Publishing, ISBN 0-89024-512-6; still in print]. I have decided to go with DCC and my local hobby store recommended Digitrax. The layout is in my basement, I will be the only operator, the plan has 54 track switches (34 NJ International twin coils and 20 Tortoise turnout motors). Can you give me an idea as to what equipment I ...

KB758 DT402 & DT400 Series Throttle Function Key

The FUNC Key is used to enter function control mode. Function control mode is the default mode for normal locomotive operation with the DT402/DT400 Series Throttles. Press this key during any throttle task to return to normal loco operation mode with function controls active on the numeric keypad.

KB241 4-digit Addressing Formula

Zephyr and systems using the DT400 will automatically program 4-digit address' with no math required. Those using other systems must manually program a 4-digit address. If you want to program a 4 digit address you simply cannot take the desired locomotive address and split the number and stick it into CV17 & CV18. The following example will NOT work: Locomotive 2345 CV17 = 23, CV18 = 45 – This isn’t how 4 digit addressing works. This method WILL work: Here is a simple method for figuring out what values belong in CV17 & CV18: The desired locomotive 4 digit address ...

KB505 Command Station Audible Beeps - DCS100, DCS200, DCS240, DB150

The DCS100, 200, 240 and DB150 use several beeps and clicks that can be used as diagnostic tools that will help you debug a number of error conditions.   DCS100/200 Audible Sounds 1 Beep           DCS100/200 has powered on successfully or has sent a programming command. 3 Beeps         A loco address has been "purged" due to non-use. This is informational only and is normal. 4 Beeps         Booster short circuit shutdown. Fault Alarm. 6 Beeps         Command station already present in system. When two command stations are operating on the same system, you may experience unexpected results. 7 Beeps         DCS100/200 CMOS battery low ...

KB178 Installing DN163A0

DN163A0 is a board replacement decoder for Atlas N-Scale GP40-2, GP38 U25B, SD35, Trainmaster, B23-7 and several others. Shown here is an installation in a GP40-2. 1. Carefully remove the locomotive’s shell from the frame. Notice the orientation of the light board inside so that you can install the decoder in the same orientation. 2. Carefully remove the plastic light shroud at the front of the loco and loosen the frame screws enough to allow the removal of the light board. Lift the board out of the frame. 3. Install the decoder, square CPU to the top, between the frame ...

KB823 Zephyr - Clear and Shut Down System

Shutting Down Your Zephyr when you are finished running.Some users prefer to release all addresses active in their system before shutting down. This can prevent unexpected results when you power up the layout again.  There are two ways to do this. ________________________________________________________________________________________________________________To release addresses one at a time (this is optional):1. Press the LOCO key. 2. Enter the loco address on the numeric keypad. The display will flash the Function Indicator Dot and the loco address. Press the LOCO key again.3. Set the Throttle Knob to STOP.4. Press the EXIT key.5. Repeat for all locos/addresses used in your session._____________________________________________________________________________________________________Alternately, you can clear all ...

KB180 Q&A - Helper District & Nesting

Is it possible for the same locomotive to be part of more than one consist? In the strictest sense, no. Nor would it be a good idea to do so since you could never be sure who is controlling a particular locomotive. It is possible to join one consist to another in what is called nested consisting. Suppose I want to use a locomotive as a helper to get trains up a steep grade. I would need to form it into a consist with several different main line locos. Is it possible to set up several consists (each made up ...

KB485 One decoder controls two locomotives

Q:  Can one decoder be wired to run two engines, such as an A-B unit that do not get separated? A:  Yes, as long as the current capacity of the decoder is not exceeded. We recommend that you check the stall current of both locomotives before installing a decoder that will handle both. Note that you can control two locomotives with decoders as a consist or MU lash-up so that you do not have to use a single decoder to control both locos.Issues we have seen with using a single decoder to run two locos together:1.  Make sure your wiring between ...

KB466 What is Stall Current

Stall Current is the max current draw in amps for a motor when it is stalled. This is important in determining which decoder to install in a locomotive. Why is Stall Current important? In the conversion of analog locomotives to DCC, how much current the locomotive draws is a major factor in decoder selection. Decoders are grouped by their ability to handle the electrical load that flows through them to the locomotive motor. The Ampere (Amp) is the unit of measure for electrical current used by the locomotive. The current draw of most HO can motors is between .5 and 1.5 ...

KB935 CV49-CV56 - FX Special Effects

Decoders with FX function features have 4 user configurable, independent special effects generators. All current production Digitrax Decoders use FX3 functions so this article is not applicapable to these decoders. CAUTION: Decoders with FX3 function generators use different CVs to control the decoder outputs. All current production Digitrax decoders use FX3 function CVs. Before using these CVs to program your decoders make sure that they are FX and not FX3 decoders.The Real FX effects are set up by programming CV values as described below.F1/F2 NOTE: If using DH142, DN142, DN141K2, DN149K2 series decoder, when F1 is set up for FX, ...

KB90 Wire Bus Standards - Copper Tape?

Needs to be investigated  Z.I am looking at buying one of your Super Chief systems. My question is :- Do you have to carry a bus under the boards or could you use an adhesive copper tape on the top of the board .  My system will be totally new; layout size 10 foot 6 inches x 8 foot.  Model Rail DVD showed this.The core power bus of the railroad is an important component.  Remember, the Super Chief will be delivering either 5 Amps or 8 Amps of electrical power.  Your interest is to make sure that sufficient power readily ...

KB313 250 Square Feet Layout

  I have an "M" shaped 250 square foot layout with 500 feet of track and twelve locomotives. What Digitrax equipment would I need? You don't say what scale this railroad will be modeled in, which is important since the locomotives in smaller scales draw less current than larger decoders. However, for purposes of estimation: Twelve Locomotives. Each locomotive is going to draw, at the very least, 5 MA for the decoder. If it has LED lights, then it will typically draw 15 MA more; conventional light bulbs will draw 50 MA. A typical H0 locomotive will draw 600 MA ...

KB474 S-Scale Recommendations

Q:  I am not sure where to begin. Dabbled in O & HO over the years and am now starting into S but have no knowledge in DCC. My layout is drawn, Dog Bone, with an over size of approx 20' by 11'. As of now there will be 8 turnouts and perhaps a turn table will be added or more turnouts. My intent is to run maybe 3 or 4 engines max. My only purchase so far is a Showcase Western Maryland, scale, which includes DCC with sound. My next comment is HELP! I do have a 2006 Summer ...

KB17 DN143K2 - Installation Instructions for Kato N RDC's

Photo Courtesy Kato, USA Installation Instructions: The DN143K2 cannot be tested prior to installation in the rail diesel car. 1. Carefully remove the shell from the RDC. Carefully remove the plastic casting from the bottom side of the RDC frame, using a flat bladed screwdriver to pry it loose. 2. Gently remove the white clip that holds the seat panel in place. Remove the seat panel by pushing up gently from the bottom of the frame. The seat panel has clips underneath that are very easy to break, so be careful. 3. Take extra care to notice how the RDC ...

KB1035 DCS240 FAQ

DCS240 FAQ   I’m getting a “StealZap” or message on my DT402 rev 2 throttle. What is this? This is a feature that helps prevent having the same address selected on multiple throttles and creating unexpected operations.  When you steal you are truly stealing control of the locomotive instead of sharing it as was the case before the DCS240 and DT402 R2 firmware were released. When using a DT402 R2 throttle with an Advanced Command Station featuring expanded slots, each throttle ID is associated with the Loco Addresses it has selected.  When you select a Loco that is selected on ...

KB934 CV50- CV52, CV62-CV63 & CV113-CV116 FX3 Special Light Effects

Decoders with FX3 features have 8 user configurable, independent special effects generators.  All current production Digitrax Decoders use FX3 function features. These are set up by programming CV values as described below.  If your decoder is not a Series 3 decoder, please check the spec sheet to determine which type of functions it supports.FX3 functions incorporate FX generators with additional dynamic and static qualifiers.  FX3 functions are fully remappable so they can be controlled by any function key on your system.  A master light switch can be set up to turn off all lights on a locomotive. Functions associated with advanced ...

KB582 DS64 Programming Q & A

  Q: Can I assume that any of the 3 powering options for the DS64 are acceptable for OpSw changes? A:  Yes you can power the DS64 using any of the 3 options.  The DS64 is strictly looking for power, and doesn't need the DCC signal from the track to set op-switches. Q: If I have only 3 turnouts on a DS64, to complete the 4 point programming I have been inputting a bogus turnout number. Is that correct? A:  Yes, that is correct. Q: When setting OpSw 1, do I have to be connected to track power or can I power ...

KB191 Case Study: PUTRA Kelana Jaya Rail Line - Background (Part 1 of 5)

The prototype operation that gains the most from DCC is one of those least frequently modeled today: Rapid transit. Rapid transit consists of streetcars, interurban, subway, elevated or commuter rail track and equipment. The trains are usually very short and intervals between trains are relatively brief. Lots of trains run each hour and many trains are running at the same time. All of this operation is very much like a typical model railroad. Any photograph of a major downtown in the streetcar era will have from two to ten streetcars visible with some only feet apart. Simulating this type of ...

KB372 LNRP - Design

Q) You are offering a Loconet Repeater Module LNRP. Is it an RailSync Booster, too? There is no description in the PDF-File about this attribute. A) The LNRP boosts (and separates) the Railsync "Standard" outputs from the master command station ("Protected" Railsync), so if there is a problem with this separated "Standard" Railsync copy, the master Command Station is unaffected along with other devices like track boosters that need good Railsync copies. This boosted Railsync is also over-current protected and the LNRP will turn off an overloaded "Standard" Railsync and automatically retry re-powering, so when the fault clears the "Standard" ...

KB624 Which Decoder Should I Use?

Our website offers a Decoder Selector Tool that can be used to find recommendations for locomotives made by different manufacturers by scale and model number.May factors will influence which decoder you choose to use for any given locomotive.1.  The physical size of the locomotive and how much space is available for the installation.2.  The current draw of the motor. 3.  How many functions do you want on the decoder?4. Is there a board replacement decoder available?5. Is there a plug for the decoder built into the loco?6. Do you want a sound decoder?7.  Other decoder features that might be important to you.

KB729 DT400 Series Throttles - Function Controls

The DT400 can control Functions 1 - 12.Note: DT400 can access F0-F12 when used with the DCS50 Zephyr or DCS100 Super Chief command station. DT400 can only access F0-F8 when used with a DB150 Super Empire Builder command station.To enter Fn (function) mode:1. Determine which throttle you want to control functions on and make it the active throttle by single clicking the throttle knob or by turning the throttle knob a couple of clicks.2. DT400’s numeric keypad is always active in function mode during normal loco operations. When the mode indicator on your DT400 shows Fn, simply press any number ...

KB308 PM42 - Local Annunciation

How can I remotely monitor the input and output status of a section of the PM42 that is configured to act as a circuit breaker at a remote location? The final output stage, of each section, of the PM4 or PM42 is a DPDT relay. The contacts of this relay act in a similar fashion as the contacts of a DPDT toggle switch. These inputs and outputs can be monitored in a variety of ways. Three common monitoring devices are a LED (with appropriate resistor), a lamp (of the appropriate voltage), or an optical coupler (with appropriate resistor). The following ...

KB352 Powering your Digitrax Command Control Railroad

Digital Command Control (DCC) has specific electrical requirements that must be provided for your layout control system to operate properly.Input PowerAll DCC systems require an external power supply.  Digitrax manufactures several power supplies for our command stations and boosters: The 3 Amp PS415 (the Zephyr Xtra power supply) The 5 Amp PS515 for all Digitrax 5 amp command stations and boosters The powerful 20 Amp PS2012 can be used for multiple 5 and 8 amp command stations and boosters  Additionally, the PS14 is available to power various other devices for your railroad.  Digitrax strongly encourages you to use our power supplies to insure satisfactory ...

KB716 Speaker Mounting, Baffles & Enclosures For Better Sound Performance

The sound performance of any speaker is greatly affected by where and how the speaker is mounted and whether an adequate speaker enclosure or baffle is installed.The baffle is used to isolate to speaker diaphragm's front side sound waves from the out of phase rear sound waves. This minimizes sound cancellation, particularly at lower frequencies. For most efficient sound generation, the volume of the baffle should be as large as practically possible. The baffle walls should be acoustically rigid to prevent acoustic interference.Practical materials to use for the baffle are plastic, cardboard and sheetmetal. Common items such as cardboard tubes ...

KB470 Layout Signaling - A Simple Example

Model railroad layout signaling is just as complicated as real railroad signaling. This is an example of how signaling might work on a small oval layout.  Once you understand how the signals work together in a simple setting, you will be better equipped to tackle signaling on your layout. The layout is a simple oval with a passing siding. Here are the locations of the individual signals: This railroad has four Absolute signals, two Dwarf signals and two Permissive signals.The four Absolute signals and two Dwarf signals protect not only the main line & the passing track but also the two turnouts ...

KB369 Walters Cornerstone Swing Bridge DCC Conversion

What do I need for DCC control of a Walters Cornerstone Swing bridge? Image Courtesy Wm. K. Walthers We do not have any direct experience with this particular bridge but after a little research, this is what we recommend.The instruction sheet which comes with the 933-1050 Motorizing Kit is quite vague.  "The unit runs on DC power.  Hook the wires up to the DC contacts on a transformer with a maximum voltage of 12.  If you hook it up to a variable speed transformer, do not exceed 12 volts.  The gear ratio is 320:1."  That said, it is still a ...

KB955 Equipment Recommendation: Small switching layout

I have a small switching layout, I am interested in low-end speed control and want to control turnouts from the hand held. What components do I need?All Digitrax command staions offer excellent low-end speed control as long as you are using decoders capable of 28/128 speed step operation.  Low speed performance will also be affected by how you set up the CVs in the decoder to define how the specific locomotive will respond to system commands.  Remember that installing a DCC deocder will not automatically improve the operation of your locos, you will need to first make sure they run ...

KB702 UP5 Power Supply and Track Indicator Connections

Hooking up the UP5's Power Supply (Optional but highly recommended to make sure LocoNet voltage is adequate to control large layouts)The optional power supply (PS14) can be connected to one or more UP and/or UR panels to provide additional power for LocoNet operation and for battery saving power to any Digitrax throttle that is plugged into any of the powered panels.1. Plug the PS14 into the DC jack located on the side of the UP5 circuit board.2. Connect the +Common point on each additional board (located between the two LocoNet jacks) to the powered board with 22AWG wire (Figure 2). ...

KB531 MRC AD310 Mobile Decoder

Q:  Using Digitrax systems to program an MRC AD310 decoder is especially confusing because the MRC Command 2000 uses several "switches" and "levers" rather than standard CV numbers. A conversion chart for the 10 possible MRC engine addresses would be a wonderful help to us old-timers. A:  The documentation available from the manufacturer of this decoder is incomplete. Many older decoders such as this one are not able to recognize all the digital packets in use by more modern DCC Systems. What we have learned is the MRC AD310 is: Programmable up to 127 (1~127) locomotive addresses Programmable for either 28 or ...

KB207 Case Study: Texas & Southwestern Part 3 of 11 - The Railroad

Based upon a layout designed by the late, great John Armstrong which appears in the classic book, 101 Trackplans for Model Railroads [Kalmbach Publishing, 400-12012, still in print], this railroad combines different elements to offer varied model railroad operations. At the center right of the railroad is the Union Passenger Station. From this station, trains can operate out & back, which is to say that a passenger train leaves the station, goes out onto the circular main line and eventually comes back into the station after passing through the reverse loop. Another passenger train can operate point to point, meaning ...

KB263 Programming track outputs and notes on Ops Mode vs. Service Mode programming

  What is the difference between programing on the layout using Track A and B and using a dedicated programing track using Pgm A & B. Is there a difference in voltage, packets, protocol between the two? Programming Track Broadcast programming, also called service mode programming, uses a programming track. The programming track is electrically separate from the rest of the railroad, and is connected to the "PROG A" and "PROG B" terminals of your DCS100/200 or Zephyr (Xtra) command station.One major advantage to a programming track is that many systems can read-back the Configuration Variables (CV's) that are in ...

KB349 Decoder Ready Locomotives?

When purchasing a loco that says its decoder ready, exactly what is implied? Does this mean wires can be wired into the numbered locations and nothing else is needed except to remove jumpers?As with any technology, it takes time for standardized terminology to become established.  Although DCC is almost twenty years old, there are still some gray areas with descriptions.  It really depends upon the individual manufacturer, and within one manufacturer's product line there can be variances also.  There are several types of locomotive decoder installations and you may find that these terms are not applied by all manufacturers in ...

KB328 Editing Routes

To go to the Edit Routes (Er) mode using DT400/DT402/DT500 series, you must pass through the clock editor: 1. Start in Fn mode. Press the EDIT Key to enter Edit Mode. Press the EDIT Key again to enter Ec (Edit Clock) mode. Press the EDIT Key again to enter EF (Edit Fast Rate) mode. Press the EDIT Key again to enter EA (Edit Alarm) mode. Press the EDIT Key again to enter Er (Edit Routes) mode. The DT400's display will show the following screen when you enter the Edit Routes mode. This display shows: Er (Edit Routes) in the Mode ...

KB348 Functions on Big Boy

I have had a Digitrax Big Boy for many years I recently bought a steam loco equipped with a Soundtraxx decoder I have been able to utilize function keys 0-4 but there is quite a few more that the decoder is capable that I don't know how to access example f6-9 Production of Big Boy was from 1994 to 1998. It was superseded by other starter sets and command stations. Big Boy can access Functions 1, 2, 3 and 4, but no higher. To reach the higher function numbers will require upgrading to a more current command station and throttle ...

KB806 DS64 - Stationary Address Programming

If you have more than four turnouts, you will need to program the addresses.The DS64 has 4 Output pairs labeled 1R & 1G, 2R & 2G, 3R & 3G, and 4R & 4G.  The DS64 is shipped from the factory with these outputs programmed as Switch Addresses 01, 02, 03, and 04 respectively. You can set the Switch Address of each of these four Outputs to any value from 01 - 2048.NOTE:  During this procedure the DS64 must be connected to an active LocoNet with an active command station.1. On the DS64’s control panel, press and hold the ID button ...

KB386 DS64 - Kato Unitrack N-Scale Automatic Crossing Gate & Three Color Signals

Q:  Is it possible to use Digitrax equipment to wire the Kato N-Scale Automatic Track Crossing? If so, how do I do it? A:  The answer is a probable "No", but there may be a workaround. The Kato, USA website notes: Some Unitrack components such as the Automatic Crossing Gate and 3-Color Signal were designed with DC operation only. So, the official position is that that these devices don't work in the DCC environment. However, we are not above speculating on how to do this, nor are others. An online web search turned up this bit of message traffic by ...

KB982 What is the DCC "Standard"?

Only the basic communications protocols are covered by the " Standard" in order to ensure interoperability and backward compatibility with existing systems. The "Standard" defines the signal sent over the rails, the tolerances allowed in its generation, the tolerances that must be accepted by the decoders and the basic communications protocol used to convey information to digital decoders. Recommended Practices cover things like the locomotive sockets and "advanced" decoder features. Manufacturers are free to design and implement DCC hardware and interfaces that make sense for their customers. Manufacturers are also free to define how the DCC packets are handled by their ...

KB333 What is Status Editing?

Status Editing - a DCC decoder's status can be manually changed by a Digitrax command station at any time the decoder is selectable. Speed steps are the increments of motor voltage that a locomotive's mobile decoder produces. Most DCC decoders can operate in 14, 28 or 128 speed steps. In some cases, older decoders operate only in 14 steps. You also may find that it is better to adjust the number of speed steps used by a particular decoder. Digitrax uses status editing to change how the command station communicates with an individual decoder. Our systems power up with the ...

KB1055 Notes from the Engineer: What is an LNWI?

What is an LnWi? The Digitrax LnWi module is a 2.4GHz IEEE 802.11 b/g/n (Wifi) Wireless Access Point type of device that logically bridges access from compatible external throttle APP(s) running on mobile tablet or smart phones onto a Digitrax LocoNet. The LnWi is an independent method for Digitrax users to control locomotives, and can be used at the same time as e.g. Digitrax Duplex or Simplex Wireless, and IR/wired throttles and other Wifi LocoNet access devices on the same system it is wired to. The design goal for the LnWi was to make it very easy for a Digitrax user ...

KB954 Equipment Recommendation: Medium/large sized layout with a reversing district

I have a medium/large sized layout with a reversing district. I want to operate 6-10 trains with several operators. I am interested in turnout control, prototypical consist operations and signaling to be added later. I might want a computer added later, too. Which components do I need?You will need a Super Empire Builder Xtra or Super Chief Xtra with additional throttles for the operators and an additional DB150 booster or PM42 for the reversing district. You will also need at least one additional DB150 to provide enough power to run 6-10 trains in N or HO. You can choose and Digitrax ...

KB105 Super Empire Builder Quick Start Guide

These instructions will get you up and running quickly. A full description of all controls and technical reference information are included later in this section of the Tech Support Depot. This section assumes that you are using a new set straight out of the box. If your set is radio equipped, we recommend that you follow this quick start guide without using radio to learn the basics. When you are successfully running your radio throttle tethered to the system, then go to the DT400 series tetherless overview article to learn how to install the radio option. Connect the DB150 to the ...

KB953 Equipment Recommendation: Large club layout with everything

We are a LARGE club layout. We have several reversing districts, 25 operators and run 30 trains at a time. We want computer control, turnout control, signaling. You name it, we've got it. What equipment do we need to run this layout?You probably need the Super Chief Xtra Set with additional throttles, boosters, mobile & stationary decoders & detectors.A typical HO layout of this size would need approximately 5 boosters & power supplies to provide enough power to run 30 engines. The DCS100 command station/booster will be one of these boosters so; you would need 4 additional DB150 series boosters. You will ...

KB943 Functions on Mobile Decoders

Digitrax decoders have outputs that can control lamps and other on/off devices installed in your locomotive.  These are called functions.  Functions are things like: lamps, sound units, smoke units, etc. All Digitrax decoders are equipped with two or more function outputs that are used to turn functions on and off.Decoder function outputs can be:1.   Leads (wires) attached to the decoder that are used to hook up external functions.  See Table I below for wire color codes used on Digitrax decoders.or2.   Pre-wired function outputs that hook up by just plugging in the decoder. This is the case for decoders that ...

KB477 PM42 - Third Party DCC Command Systems

  Q:  Can I use a PM42 with a non-Digitrax DCC Command system? A:  The PM42 was specifically designed to work with Digitrax Direct Home wired layouts. Any system that is configured this way will probably work with the PM42 with no interoperability issues. Digitrax has no control over or knowledge of each specific non-Digitrax system and how it may interact with the PM42. The PM42 can be used as a stand-alone auto-reversing unit and short circuit manager with many third party DCC systems, but for systems without LocoNet capability a number of the networked management features will not be available. ...

KB200 Case Study: Texas & Southwestern Part 8 of 11 - Programming Track

One special feature on the Texas & Southwestern is a built-in programming track. The programming track is located in a short section of track in the small engine terminal of the T&SW. This track has both rails insulated from the rest of the railroad. It uses a Double Pole Double Throw (DPDT) toggle switch to select what purpose this section of track is used for. When the toggle switch is set in one direction, the track has DCC power on it. When the toggle switch is aligned in the other direction, the track is now connected to the programming terminals ...

KB91 Powder River Signaling Example

I am now constructing an N-Scale layout with Digitrax DCC system. I know SE8C and two-heads signal mast supplied by your company are applicable for a entry signal mast for the both of main and siding (branch) lines. However, I don't know how the signal mast is used in the case of "more than two" siding lines. For example, the next picture was taken in Powder River Basin (Converse Jct.) in Wyoming State. TS, Japan In this picture, some two-heads signal (mast) can be seen. In every signal mast, the top signal head will be for a main line. But, ...

KB166 Avoiding Heat Problems With Decoder Installations

Most HO, N & Z Scale model locomotive motors and lamps are designed by the locomotive manufacturers to operate at full speed at 12 volts DC on the track. Digitrax recommends running your DCC command station and boosters at the lowest track voltage possible that provides acceptable operation. The “N Scale (12V)” setting on Digitrax equipment works for most HO, N & Z scale layouts. Some DCC systems made by other companies supply more voltage to the track and are not adjustable. If the track voltage applied exceeds the operating parameters of the locomotive and its lamps, it is possible ...

KB967 Is a separate "feedback bus" needed for transponding?

I understand that LocoNet is used for transponding "feedback."  How can Digitrax systems handle both DCC and transponding without interfering with other track level communication and without adding another communication or feedback bus like other system have to do?LocoNet is a true network with future expandability built in. Part of that future is here now with transponding. LocoNet was engineered from the very beginning with things like this in mind.If you are already using Digitrax LocoNet, you will not have to add a "feedback bus" since this is already incorporated into LocoNet's design! If you are using transponding with a ...

KB465 Basic DCC Components

How does DCC work? You use a throttle (cab) to tell the system what you want a train to do. The throttle sends the information to the command station. The command station makes a digital packet out of the information and sends it to the booster. The booster* adds power to the digital packet and sends it out through the rail. The decoders in all locomotives (even those that are not running) read all digital packets, and decipher them to get the address contained in the data packet. If the packet address matches the decoder address, the decoder uses the ...

KB222 Sound in tunnels

Is there a way to automatically decrease the sound on my sound equipped locomotives when they go into a tunnel? No, but you can use F8 to mute the sound when you enter the tunnel and F8 again to turn it back on when you exit the tunnel.Some clubs have "no chuffing" zones, where many trains are present at the same time. Operators who do not know about F8 are quickly apprised by others when they enter a busy yard.   F8 Mute (CV135) may be changed to a non-zero value, such as CV135=16 to lower the sound volume.  This ...

KB204 Case Study: Texas & Southwestern Part 7 of 11 - The Reverse Loop

The Texas & Southwestern has a reversing loop, and DCC insures reliable and simple operation of trains in the reverse loop. This reverse loop is handled with a Digitrax AR1 Auto Reversing Controller. The automated features of the AR-1 make for seamless train movements, but an issue quickly arose. Because a reverse loop in a traditional DC-powered model railroad environment required manual operation, the track insulating gaps for the loop were usually located for the convenience of the operators. So the track gaps of the original track plan were situated to keep this inconvenience to a minimum. Note also all ...

KB695 TF4 - Installation Instructions

Installing the TF4 in the Loco or Rolling Stock1. Connect the TF4's RED and BLACK wires to the matching RED and BLACK track feed wires of an installed DCC mobile decoder.2. If the TF4 is used by itself, for example in a caboose or box car without a DCC mobile decoder installed, connect the TF4's RED wire to the right hand track pickup and the TF24s BLACK wire to the left side track pickup.3. No other parts are required to set up the transponder current pulses, since this is self-contained in the TF4.4. Install the lamps using the TF4's blue, ...

KB220 Selecting another locomotive at speed

What happens when I select a loco that is currently running at a different speed than the throttle is set to? example... running loco 'a' at half speed then switch to loco 'b' does loco 'b' suddenly change speed to half throttle? (which is the last position the knob was indicating for loco 'a' this would make for a nice crash if I planned on backing loco 'b' out of a siding, and it goes forward instead at 50% right into a bumper) You're right, when switching the loco 'b', the newly selected locomotive would be commanded to operate at ...

KB842 What are CVs (Configuration Variables)?

CVs are decoder memory locations that hold loco address, operational  configuration and performance settings. Adjusting them to customize the performance of a specific locomotive is one of the main advantages of DCC over DC running. - Doug StuardThese are special storage locations or "pigeonholes" in your mobile decoders. By programming various CVs, you can control each decoder's performance characteristics. CVs store information like the decoder's short address, long address, start voltage, mid-point voltage, loadable speed tables and many more. Once you have programmed these characteristics, the decoders "remember" them until you change them again. Most manufacturers use a similar set ...

KB189 Case Study: PUTRA Powering the Kelana Jaya Rail Line (Part 3 of 5)

The Kelana Jaya Rail Line model is a DCC intense layout, using many Digitrax command control components to achieve the goal of training operators of the actual rail line. The railroad was built in the 1990's and many of the Digitrax devices used for the Kelana Jaya Rail Line model have been superseded with improved units. Components used for the Kelana Jaya layout: 28 Mainline turnouts 11 Yard turnouts 39 Tortoise switch machines 84 Dwarf signals (yellow/green, red/green, red/yellow) 38 Mainline block signals 38 Heavy duty SPDT switch relays Digitrax Components Used for the Kelana Jaya layout: 1 DCS 100 ...

KB343 Sound Project Files

Fred Miller has been an invaluable resource for information about Digitrax sound. Here are some of his thoughts about the sound project files, from the Yahoo Digitrax Sound discussion group: There seems to be confusion over what is a SPJ.  Yahoo closed down all Groups in 2019.  The information is still relevant.   Fred Miller has also written a program called SPJHelper which easily lets you create/modifiy Sound Projects. There are additional Sound Projects on Groups.io - Look for AnPRR owned by John McMasters.  He creates many SPJ Sound Projects.   It is not surprising since it is a very ...

KB18 Atlas Up & Over Dogbone

This Atlas Snap-Track layout appears in the Atlas Model Railroad Company's book "Beginner's Guide to HO Model Railroading". It includes a reversing section which can be controlled with a Digitrax AR1. DC Control For DC operation, Atlas specified an Atlas Controller (for the reverse loop), two Atlas Selectors (to control eight track segments) and seven controllers for the railroad's turnouts. DCC Makes Things Simple With DCC, the wiring of this railroad is considerably simpler. Because each locomotive has a unique address, the section insulated gaps and the two Selectors are not necessary. Likewise, the Controller is replaced with the AR1 ...

KB229 Running Multiple Layouts On One Command Station

I am building a layout that will have two completely separated track plans; not connected with each other by any track. I am running one layout with a Super Chief that has one AR1 reversing controller.  I would like to run the second layout with the same throttle. It will have a reversing loop, as well as a turntable.  I have thought that I could run the second layout with a booster and a couple of AR1s or PM42.My questions is, will I have any problems with the reversing loops, especially if one on each layout is triggered at nearly ...

KB353 Sound Decoders and the white cam lead

I don't understand what the white cam lead gets hooked up to. Some model steam locomotives are equipped with, or can be equipped with, a cam arrangement which coordinates the sound to the rotation of the drivers creating chuffing. As the wheels turn, a switch opens and closes, operating the chuff sound produced by the sound decoder. The white wire goes from the decoder to a microswitch which is operated by a cam that is mounted on the axle of one of the drivers. In operation, when the white wire senses the DCC track signal, it operates the chuff sound ...

KB835 Zephyr - Stealing A Locomotive

Another way to describe "stealing" is "sharing"; it is a process where one operator can mutually control a mobile decoder with another operator.This feature can be useful for training new operators or supervising engineers who insist on breaking the speed limit. The supervisor can "steal" a locomotive that is selected on a trainee's throttle and be able to closely supervise that locomotive's control, taking over when necessary. The supervisor can gain instant override control without having to physically "grab" the trainee's throttle. This lets you have unskilled visitors participating and enjoying operations without too much anxiety for either party.If you ...

KB68 Case Study: Nemo Junction Connecting Signals to the SE8C Part 9 of 9

The Nemo Junction module has a total of seven color light signals that regulate the flow of train traffic through this interlocking plant. Controlling the Signals with SE8C The SE8C is the signal driver, sending current to the various LED's of the color light signals. Each signal is operated via switch commands from the Zephyr. The SE8C has eight Driver Sockets, identified as DRV1 - DRV8. : A Signal Driver Cable (a 10-conductor ribbon cable) is plugged into a SE8C Driver Socket to control as many as four signal heads per Driver Socket. Each signal head can display 4 lighting ...

KB909 Track Voltage Measurement on DCC Layouts with Direct Home Wiring

Track voltage on DC (analog) layouts can be measured from rail to rail.  However, with DCC layouts that use direct home wiring as recommended by Digitrax, this method of measurement does not work with most voltmeters.Track voltage (output from the booster to the rail) on DCC layouts with direct home wiring can be measured as follows:1.     With the system powered up and with the TRACK STATUS LED on, use your throttle to select the analog address 00 and set the speed to 00.2.     With a multimeter set to the 20 volt DC scale, measure the voltage from RAIL A ...

KB606 PR2 Use With USB

This application note shows how you can use your Digitrax PR2 Programmer with the USB Port on your computer. The PR2 has been replaced by PR3 Programmer and Computer Interface.  PR3 offers USB connectivity.The PR2 Programmer is a serial device that connects to a computer via a 25pin serial port. Serial ports are not available on most computers in current production. USB ports are more widely used today. The Digitrax PR2 Programmer can be connected to a USB port by using a USB to Serial RS-232 DB-25 Adapter Cable. Caution: Not all cables on the market will work. One that ...

KB602 Can I upgrade or update my DT100 throttles?

Q: I have an older Super Chief system that came with DT100 throttles. They are both shot; one was accidentally pulled apart by an over zealous operator who forgot about the cable length and the other was ruined by me (I'm ashamed to admit) by spilling some super glue on several of the buttons. Can I upgrade to the current throttles or do you recommend I purchase the old DT100 units? A:  All Digitrax Starter Sets have LocoNet, including your older Chief series unit. This means that you can use any Digitrax throttle past and present.  Both of your damaged DT100 ...

KB202 Case Study: Texas & Southwestern Part 9 of 11 - Zephyr Heat Build Up

From the start, the Texas & Southwestern was built with DCC in mind. The T&SW was built from the ground up by an individual with considerable model railroad experience, but an issue arose that defied explanation. The T&SW was meant to be operated with a DCS50 Zephyr, and the layout support structure was enlarged slightly to fit the Zephyr into one corner of the railroad. As it turned out, the cozy corner space for the Zephyr turned out later to be a bit too cozy. The bottom of the Zephyr has ventilating slots to help cool the unit’s electronics. As ...

KB15 HO-Scale Transbay Interwoven Track Plan-Auto Reversing

This H0-scale railroad track plan first appeared in the Atlas Model Railroad Company's book "Six Railroads You Can Build", written by John Armstrong and illustrated by Tad Stepek. This book was first published in 1958 and has been reprinted several times. A classic bowl of spaghetti, the Transbay Interwoven has two reversing loops and a turntable. DC Control For DC operation, Atlas specified three Atlas Controllers (for the reverse loops and the turntable), two Atlas Selectors (to control eight track segments) and ten controllers for the railroad's turnouts. DCC Makes Things Simple With DCC, the wiring of this railroad is ...

KB407 SE8C Signal Controller Address Ranges for Signals and Other LocoNet Devices

The SE8C uses switch addresses to operate the signals, so you may need to change some factory settings to make it work in conjunction with turnouts that are already installed on your layout. Be sure that when you configure the SE8C that the switch address ranges you select to operate the signals do not conflict with other devices, like DS64s, that are already installed. We strongly recommend that you keep accurate documentation of the address ranges used to control all devices on the layout to avoid conflicts that might cause problems. Without this record it can be very difficult to ...

KB884 Wired Decoder Installation in Atlas/Kato GP30/35

These instructions detail the installation of a wired Digitrax decoder (a DN140 in this example, but many wired decoders may be used) into an Atlas GP35 manufactured by Kato prior to September, 2007.  These units are marked "Japan" on the bottom of the locomotive.  Units marked "China" use a board replacement decodr such as the DN163A2.Installation DiagramNotes:A. Be sure motor leads (Gray & Orange) do not touch frames & have protective insulation in place.B. Be sure frame is straight & mechanism is correctly reassembled & can turn freely without binding.Wired Decoder Installation InstructionsFollow these steps for decoder installation with either ...

KB547 DS54 - Flashing Railroad Signal Crossing

Q:  How can the DS54 be configured to control a Flashing Crossing Signal? A:  The elements necessary to create a simple function flashing/blinking crossing signal are: a block occupancy detection (trigger) device, an electronic flashing/blinking circuit (DS54) and a crossing signal. The DS54 can accommodate two different types of triggering devices: Digitrax block occupancy devices (BD1 and BD4) and third party block occupancy devices (such as magnets and reed contacts). The following drawings indicate how to connect the two different types of triggering devices, along with the crossing signal, to the DS54. The upper drawing is for the BD1 or ...

KB265 DB150 Option Switch Setup

The DB150 has many customizable system operation options that you can set. The DB150's power up defaults are fine for most applications and the DB150 will run just fine right out of the box. These options are provided for those individuals who want more flexibility in setting up their operations. The factory default setting for all DB150 option switches is t or thrown except for 5, 17, 25, 33 and 34 which are closed ("c"). Changing DB150 Option Switches 1. Consult DB150 Option Switch Table to determine which DB150 option switches you want to change. 2. Move the right toggle switch on the ...

KB203 Case Study: Texas & Southwestern Part 11 of 11 - Future Expansion

As originally conceived, the Texas & Southwestern was set up with a very simple DCC system. The railroad uses a DCS50 Zephyr as its command station and booster. The Zephyr is connected to a central power bus, and all tracks, stationary turnout decoders and the automated reverse loop unit are connected to it. Likewise, the LocoNet connections are a series of simple cable connections starting at the Zephyr and ending at the last Universal Panel. The T&SW works well with this arrangement, but there are additional devices that will enhance the operation of this railroad. Digitrax PM42 Power Management System ...

KB872 Marklin 6027 Command Station Using Digitrax Boosters

This Application note shows how Marklin Users can have the power and reliability of Digitrax boosters along with their Marklin command stations! Notes: 1. Before applying power to the booster, use a short length of wire to short the 2 gray terminals (SYNC & GROUND) on the DB100. This forces the DB100 into the booster mode when the power is applied to it. Set the MODE switch to "P/R" for auto reversing operation or to "RUN" for normal booster operation. 2. Make a cable with 6 conductor RJ12 cable with a 6 conductor male plug on the DB100 end and ...

KB52 BDL168 - Is a Heatsink Necessary?

The BDL168 does not require a heatsink to operate efficiently, however, large scale operations may generate higher heat levels with the BDL168 and you can make your own to add to the unit. The BDL168 design does not include a provision for a heatsink. There is not a kit available for adding on a heatsink, but you can make your own if you believe it necessary for your system. The following drawing will provide the correct measurements to produce a heatsink that will slip in between the two rows of rectifiers on the BDL168 Circuit Board. This will raise the ...

KB1018 DCS100/200 as a Booster

Many clubs use a DCS100/200 as a Booster in their setups.  Digitrax does not recommend using a DCS100/200 as a Booster only for this type of setup.  If you decide to do so, please keep this information in mind:   The DCS100/200 configuration is stored in memory that uses a CR2032 battery.  Over time the battery can get weak and the DCS100/200 will loose its ability to store its configuration.  When this happens, the DCS100/200 will sound 7 beeps at power up.  It will also revert back to its factory settings and once again become a Command Station.  Since LocoNet ...

KB846 Zephyr - Programming Mobile Decoder CV's Other Than Locomotive Addresses

There are many different CVs that have been defined to control operating characteristics of your locomotives. Your decoder manual has a complete listing of CVs that are available with specific decoders, what they do and suggested values for each CV. Programming these CVs is simple:1. Be sure that only the locomotive you want to program is on the programming track.2. Press the PROG Key to enter programming mode. The DCS50 will display one of the programming modes available. Digitrax recommends the Paged Mode when you are using the programming track. As you press the PROG Key repeatedly, you will cycle ...

KB829 Zephyr - Decoder Speed Step Settings & Status Editing

The Digitrax DCS50 Zephyr is set at the factory to send 128 speed step commands to all mobile decoders.If you have a non-Digitrax decoder that can’t run in 128 speed step mode, you can change the number of speed steps the DCS50 sends to that decoder so that you will be able to control the decoder. This is called status editing the decoder. When you status edit a decoder, the DCS50 will send a different format to that specific decoder address without affecting the 128 speed step operation of Digitrax decoders and other 128 speed step decoders on the railroad.NOTE: ...

KB977 PM42/PM4 Differences

What's the difference between the PM42 and the PM4?The PM42 is an improved version of the PM4. We added 2 faster short circuit detection sensitivity settings and revamped the manual. Get the benefits of short circuit management and auto reversing without adding more boosters! PM42 Quad Power Manager lets you use a single booster and divide its output into 4 power sub-districts for automatic reversing &/or to improve operation by preempting booster shutdown when a short circuit is detected by the PM42. If you want to improve operation but don't need the added power (or expense) of adding a booster, ...

KB116 Small Layout Booster Requirements

Do I need an additional booster if I run isolated sections through a PM42 or can I use one Zephyr?  This is a small layout design (5X9) and looking to make it as simple and safe as possible.This is really a question of how much power your railroad requires.  You don't state what scale you are operating in, so a 5x9 in H0 might only have three or four locomotives, while a 5x9 in N-Scale might have fifteen or twenty locomotives.Initially, you will be making an estimation based upon your power requirements and the output power of the 2.5 Amp ...

KB148 Minitrix 6-Pin Socket

We have discovered during a conversion of an earlier Minitrix V60 diesel that the 6-pin socket is not always wired correctly for conversion to DCC. Apparently, earlier Minitrix locomotives equipped with this socket were wired for use with Selectrix decoders. You should examine the connections from the locomotive to the 6-pin plug prior to installing the DZ125IN.

KB526 DS54 Address Programming

Q:  What is the procedure for programming the DS54 Address using the Programming Address Button? A:  The procedure for programming the DS54 address using the Address Programming Button is simple. This procedure only requires the determination of the turnout addresses block for the DS54. During the programming cycle the activation of any turnout address within the desired turnout address block will automatically set the DS54 to the proper module address. 

KB867 Using Cat 5/6 Cable On LocoNet

Shielded otr Unshielded Twisted Pair like cat5/6 is not recommended for LocoNet.  This kind of cable can causes problems due to capacitive load. These issues were observed during the National N Scale Convention in Louisville, KY on a large layout using Twisted Pair cables.  The issues were resolved when the cables were replaced.

KB106 Super Empire Builder Components

Your Super Empire Builder Starter Set contains: The DB150, which is the system’s DCC command station. It generates the DCC signals that control decoders and other devices on your layout. The DB150 is also a DCC booster. Boosters receive DCC signals from the command station, amplify them and put them on the track along with the power from the transformer to run the locomotives. You can have several boosters on your layout to provide additional power to run more locos. Depending upon the set, there is either a DT402 or DT402D (duplex radio throttle), which is the DCC throttle that ...

KB206 Case Study: Texas & Southwestern Paft 5 of 11 - Powering the Railroad

Good DCC practice means good planning for the electrical needs of the railroad. Here, we talk about the power needs of the Texas & Southwestern. Anticipating Power Consumption The core of the Texas & Southwestern's DCC control system will be the DCS50 Zephyr, which is very appropriate for a small railroad. Zephyr has 10 "slots", memory locations in the command station each holding an active decoder address. Rated at 2.5 Amps, the Zephyr should also be enough to handle the power needs of the railroad, but if more power is needed, then T&SW can easily be expanded with an additional booster ...

KB926 CV55, CV56 & CV57 - Scaleable Speed Stabilization (Back EMF)

Some Digitrax decoders offer scalable speed stabilization (also called back EMF) control to help smooth out operation in the low end of the speed range.  This feature can be beneficial especially in N scale switching situations especially when the decoder can select how much of this effect to implement (scalable speed stabilization).  Speed stabilization is a decoder feature that can be used with any DCC system.  Most Digitrax decoders that support this feature are shipped with scalable speed stabilization turned off so, to use it you will need to set program them to use this feature.  Other Digitrax decoders are ...

KB607 Resistance wheel sets

Railroad signaling works based on detection of trains on the railroad.  If a train is detected, then the signal system goes into action, setting up indications that let show that the track section is occupied and warn other trains that the section is occupied.  At a grade crossing where a railroad and a highway intersect, the presence of a train starts the crossing signals and lowers the gates in time to stop highway traffic so the train can pass.In the case of real railroads, detection is easy, since the rails are naturally insulated from each other and either a locomotive or ...

KB293 Digitrax LocoMotion System

What is the Digitrax LocoMotion(™) System? The LocoMotion(™) System is available with many decoders. It offers: 128 speed step control Smooth deceleration to stop before changing direction when locomotive is reversed Torque compensation for the smoothest operation ever Momentum with acceleration and deceleration settings Set normal direction of travel for your loco Switching speed feature for quick access to slower switching speeds Simple 3 step speed tables are easy to set up Advanced 28 step speed tables with 256 level resolution Series 3 decoders have smooth scaleable speed stabilization feature

KB690 Turnouts and DCC

"Turnout" is a civil engineering term for what railroaders call a "switch".  In the model railroad environment, we often use the word turnout to avoid confusion with the electrical term "switch".  On the railroad, throwing a switch usually only means one thing, while "Throw the switch" on a model railroad could mean operating a light switch.Probably the best answer is to consistently use one type of turnout.  The notion of a "DCC Friendly" turnout is a myth; the standard answer in the past has been: "If it worked on DC it will work on DCC". In the end, which turnout ...

KB580 Zephyr Xtra - Making DCS51 or DSC50 a Booster/Throttle

How to disable command station capability in a DCS51 (Zephyr Xtra) or DCS50 (Zephyr) so it will operate as a booster and throttle without command station capabilityIf you have outgrown your Zephyr Xtra or Zephyr and have moved up to a more powerful command station, you can disable the command station capability in your DCS51 or DCS50 and continue using it as a booster and throttle in your system.Digitrax operators who upgrade from Zephyr to more powerful command stations for their systems can change Zephyr into a Booster/Throttle by setting OpSw 02 to closed. Changing DCS51/DCS50 Option Switch 02 to closed to disable command station capability: ...

KB472 Layout Blocks - A Small Example

Train detection and the related signaling can be a complicated affair. However, it becomes easier if you analyze things and break them down into their component blocks. The whole idea is to protect trains from each other, regulating their movements by the use of signals which tell train crews what to do or what to expect. Train detection identifies which segments of track are occupied by a train. For the real railroads, track detection sections can be very short (such as at track junctions) or very long (such as in rural environments). Train speed and frequency of trains are also ...

DH163A0 1.5 Amp Decoder fits many HO Diesel Locomotives (Product Support Page)
1.5 Amp Decoder fits many HO Diesel Locomotives

DH163A0 fits many HO Diesel Locomotives: Athearn Genesis, Kato, Stewart & Atlas. Retired in 2007

DH163K0 1.5 Amp Decoder fits many Kato HO Diesel Locomotives (Product Support Page)
1.5 Amp Decoder fits many Kato HO Diesel Locomotives

DH163K0 fits many Kato HO Diesel Locomotives Retired in 2007

DH165K1A 1.25 Amp HO Scale Mobile Decoder fits many Kato Locos (Product Support Page)
1.25 Amp HO Scale Mobile Decoder fits many Kato Locos

DH165K1A fits many Kato HO Diesel Locomotives. Compatible with Digitrax Sound Bug Decoder Lock equipped

DH165L0 1.25 Amp HO Scale Mobile Decoder fits many Lifelike GP7/SD60 Locos (Product Support Page)
1.25 Amp HO Scale Mobile Decoder fits many Lifelike GP7/SD60 Locos

Series 5 Decoder for Proto 2000 Plug ‘N Play Installation Compatible with Sound Bug Decoder Lock equipped

KB860 Zephyr - Selecting and Running your DCC Locomotive

To select and run a DCC equipped locomotive with a known address follow these steps:1. Set the DCS50's Throttle Knob [1] to STOP. 2. Place a DCC equipped locomotive (one with a decoder installed) on your digital layout that is controlled by your DCS50. In this example we assume that you have a new Digitrax decoder that is factory programmed to address 03. If your decoder is using a different address, simply use that address as you follow these instructions.3. Check the DCS50's Track Status Indicator Dot [4] to be sure that track power is turned on. Press the POWER ...

KB14 Switching Layout Examples

At first glance, the typical switching railroad would not seem to be a good candidate for DCC operations. Yes, there may be only one locomotive on many of these railroads, but that locomotive can still benefit from DCC. By adjusting the starting, mid-range and maximum speed values of this locomotive, you get very good slow speed control, perfect for the switching railroad. And, of course, if you add a second locomotive, then DCC becomes the clear choice because you are not longer having to throw toggle switches just to move around the yard. The DCC environment also gives you turnout ...

KB205 Case Study: Texas & Southwestern Part 6 of 11 - Wiring the Railroad

This section discusses the installation of the physical wiring of the Texas & Southwestern. Underneath the completed Texas & Southwestern are various wires and cables which allow you to operate your railroad. Initially, seeing all these wires can be intimidating, but as you will note, they have been grouped and bundled so that identifying the individual wires is easy. There are two groups of wires under the railroad; one group, the power bus, delivers power to the tracks and to the stationary decoders that operate the track switches. The other group of wires is the black cable for LocoNet and ...

KB897 Roundhouse "Critter" Decoder Installation

1) Remove locomotive shell following Roundhouse instructions.2) There are two large diodes, one on each side of the rectangular light board. Remove them.3) The two LEDs are wired to this light board, one on each side with black and gray wires on each LED. Reverse the black and gray wires on the board from each LED (gray to where black was and black to where gray was.4) Remove the dummy eight pin plug and insert the eight pin DCC medium plug of a Digitrax DZ1xxPS decoder with the orange wire going to #1 on the light board.5) Reinstall locomotive shell.FAILURE ...

KB559 Lenz & Atlas decoders show d-nd

Q:  My Atlas DCC N-Scale locomotives that are equipped with factory installed Lenz062xf, Lenz063xf or 'new' Atlas decoders will not program using the DCS50 in any mode, either on the OPS track or Program track. I know the system works because I can easily program every Digitrax decoder loco that I have, but if I put an Atlas DCC factory loco on the programming track I get the 'd nd' error code   There are decoders now presnt in the market that do not draw enough current for the programming track to reliably detect that they are present, hence the ...

KB700 TL1 - Programming Address & Function Outputs

1. Before using your TL1, set its address. This may or may not be the same address as a mobile decoder already installed in the loco or car depending on how you are planning to use the TL1. In the case of TL1s being used as a stand alone transponder or as a function decoder, choose an address that is not associated with another mobile decoder address in use on the layout.2. Connect the RED & BLACK wires of the TL1 to a service mode DCC programmer and program the TL1's address as you would any mobile decoder address.Follow the ...

KB98 Setting Up a Programming Track with DB150

If you want to change the address or other settings of your locomotive decoders, you must set up a programming track. It is very important that the rest of your railroad can be isolated from the DB150 and the programming track when you are programming a locomotive. Decoders are programmed when the DB150 command station sends programming information to them through the rails. There are two basic ways of programming decoders. Service mode programming broadcasts a message to all DCC equipped locos that are on the track. Because this is a broadcast method, you will need to set up a ...

KB113 Boosters and Power Management

What is the difference between boosters and power management? A Booster is the device that provides the electrical power to the railroad. Most Digitrax command stations have a combined booster. The command station generates the DCC signal then sends it through a booster to the layout. A small model railroad may only have the command station and booster, while a large railroad will have numerous boosters. Multiple boosters provide more power to larger layouts.Additional boosters receive the DCC signal from the command station via LocoNet. Power management usually refers to the devices which act as circuit breakers and power distributors. ...

KB160 Rotary Beacon for Athearn MP15 with DH163AT Decoder

I have a Athearn HO Scale MP15 Soo Line and have installed a DH166 decoder. How do I get the rotary beacon to flash? Function Outputs on the DH166 The DH166 is set up at the factory to control six function outputs. The DH163AT is configured to control the forward and reverse lights on the locomotive through the yellow lead and white lead using Function 0 (F0F-forward yellow and F0R-reverse white) for directional lighting. Functions F1(green) and F2 (violet) are part of the harness for easy hookup. F3 and F4 are also available on the decoder board. These can be ...

KB223 Walthers Turntable (933-2829)

  I have just purchased a Walthers 90' turntable that is DCC ready [sic]. How do I connect this? It appears to have a LocoNet connector. Any help would be great. Walthers manufactures two different turntables in H0; the 933-2829 is an automated turntable with full track indexing. While both can be operated in the DCC environment, the Walthers turntable is not DCC ready in the manner that you assume. What appears to be a LocoNet connector is actually the connector for the turntable's proprietary controller. Full documentation for this turntable is available at the Walthers web site.

KB512 DS54 - One Button Turnout Application

  How to Configure the DS54 for one-button turnout controlThe local buttons, throttle, or any other turnout control device connected to the LocoNet can control the DS54 output when the DS54 is connected to the rails. The following drawings indicate the general wiring schematic for a one-button control of a turnout using either a Dual Coil (upper) or slow motion (lower) switch machine. The following two charts indicate operating criteria and CV settings for one-button turnout control. 

KB510 DT400 Series - Throttle Clicks

Q: I have a Digitrax DT400 throttle. The left speed knob accelerates the locos at one speed unit per "click". However the right knob accelerates at three speed units per "click". How can I change the right knob to one unit per click? There is not a way to change the clicks to one per unit. Each rotation of a throttle knob on the DT400 series throttle generates 24 clicks.  Digitrax supports 14, 28 and 128 speed step operation in decoders; each click on a DT400 series throttle knob is related proportianally to the number of speed steps used by the decoder. So, for a ...

KB754 DT402 & DT400 Series Throttles Y (+) & N (-) Keys

The DT402/DT400 Throttles include two multipurpose keys.The Y + and N - Keys are used: To turn track power on and off   To increase or decrease loco speed   To link and unlink locos during MU’ing   To accomplish tasks using system editors These two keys can be set up to act in two different ways:Repeating: so that if you hold a key down it will continue to increase or decrease step by step until you release the key. This option is active when your throttle is set up for ballistic tracking. Your DT402/DT402 throttles are shipped from the factory ...

KB181 Single Programming Track - Multiple Programming Sources

How can I connect my PR3 programming output to an existing programming track on my layout that is already set up for programming and mainline operations? Install a non shorting multi position rotary switch between a isolated section of track, 4-6” longer than your longest engine, and the various desired outputs from command stations and the PR3 output terminals. The following schematic allows a single section of track to be fed by the rail output of a command station, the programming track output of a command station, and the programming output of a PR3. To add other third party decoder ...

KB890 Installation of Digitrax DH121 in Bachman Hogwart's Express

Many thanks to Dick Sutcliffe, Superintendent BR &T Railway Co. for this application note!Install the DN121 in the tender   1. The tender is easy to open by removing two screws so you can pull the decoder out and put in a plug when running on DC layouts.   2. Use a piece of styrene to raise the decoder off the weight.   3. Notch the front edge of the tender frame to bring the wires through to loco (all power pick up is in the loco).   4. Split the loco frame to isolate the motor brushes, remove the contact springs in the ...

KB692 Testing LocoNet Cables with LT1 Tester

To Test LocoNet Cables With an LT11. Unplug the wire harness from the LT1.2. Plug one end of the LocoNet cable you want to test into the LT1.Note: When making your own LocoNet Cables, it is important to make them in a consistent manner. At Digitrax, the white wire is always on the right side of the plug when the plug is viewed with the clip at the top.3. Connect the other end of the LocoNet Cable being tested to any powered Digitrax Booster’s LocoNet Port A or B. Be sure you have at least one Digitrax throttle plugged in ...

KB280 Matching Speeds inside a consist

How do I get all the engines of a consist to run at the same speed? I have 3 engines with DH163A0 decoders and one with a MRC sound decoder. All units have the same top speed, but the unit with the MRC decoder starts and accelerates more quickly. Getting a group of locomotives to operate at the same speed can be a challenge. Experience has proven that it is best to work with the slowest locomotive and bring the other locomotives into agreement with that engine. Since the others appear to be in general agreement, it would be the ...

KB626 DCS50 Zephyr 4 Digit Address Worksheet

For Tower 55 and other locomotives that require 4 digit address to be programmed using CV17 & CV18 instead of the normal Digitrax Throttle Automated method.To determine the values to program into CV17 and CV18, please complete the following worksheet before beginning the 4-digit address programming procedure.1. Write the 4-digit address to be programmed into the decoder here: _____________2. Take the 4-digit address from step 1 and divide by 256. (Result from step 2 = ____________)3. Take the digits to the left of the decimal point in the result from step 2 and add 192. (Result from step 3 = ...

KB848 Zephyr - Changing a Locomotive Decoder's Address

1. Be sure that only the locomotive you want to program is on the programming track.2. Press the PROG key on the DCS50 to enter programming mode. The DCS50 will display one of the programming modes available. Digitrax recommends the Paged Mode when you are using the programming track. If you press the PROG key repeatedly, you will cycle through the following choices: PAGE   PHYS   dir   OPS For example, to use Paged mode stop pressing the PROG key when the following screen appears:Each time you press the LOCO key the display will toggle between Ad2 and Ad4. ...

KB362 Atlas DCC Decoder Programming Problem ("d nd") on DCS 50

  My Atlas DCC N-Scale locomotives that are equipped with factory installed Lenz062xf, Lenz063xf decoders will not program using any mode on Program track. I know the system works because I can easily program every Digitrax decoder loco that I have, but if I put an Atlas DCC factory loco on the programming track I get the 'd nd' error code.   There are decoders now present in the market that do not draw enough current for the programming track to reliably detect that they are present, hence the error report of "d-nd". All you have to do is to ...

KB804 DS64 - Set Up Using Option Switches (OpSw)

DS64 is set up by setting Option Switches (OpSw)This is how to set option switches on the DS64:1. Begin with your DS64 powered up. Turnouts can be either connected or not.2. On the DS64 press and hold the OPS button down for about 3 seconds until the red OPS LED and green ID LED begin to blink alternately. This indicates that the DS64 is ready to change the option switches.3. Using your DCC throttle, select the Switch Address that corresponds to the OpSw number and send the Closed or Thrown command corresponding to the setting you have chosen. Refer to ...

KB528 DS54 - Block Occupancy Application

  Q: How can I configure the DS54 for block occupancy detection? A:  Any DS54 input can serve as a block occupancy message generator. All that is necessary is to activate a DS54 input with a device that can detect the presence of a train within a specific area/location. The DS54 input can respond to a number of different block occupancy devices including the BD1, BD4, and isolated contacts. The following drawings indicate two different methods (wiring schematics) for the connection of devices to the DS54. The upper drawing Is for isolated contacts and the lower drawing is for BD1 ...

KB115 DS64 - Powered Frogs

Can I use the DS64 to power frogs in Atlas turnouts with solenoid ( code 83 ) type switch machines? No, the DS64 does not have internal contacts to provide power to the frogs. This could be done by using a switch machine with its own contacts; these have been made by NJ International, Tenshodo, PFM and others. Another alternative would be to use the Atlas Snap Relay. The Snap Relay is a solenoid device like the switch machine, but instead of throwing the turnout, it throws a set of electrical contacts. The relay is wired in parallel to the switch machine, ...

KB3 UR92 - DigiGroupSetup Read Me

The DigiGroupSetup utility is in a ZIP file which is provided for Digitrax customer convenience and can be downloaded from our downloads page. Read Me Text File with DigiGroupSetup This utility is provided on an as-is basis for users with a Windows based machine configured to work with this software, and the ability to perform the setup and operation tasks detailed below. Techsupport is not configured to diagnose issues related to operating system, hardware, configuration or other possible problem areas that may cause problems with running these utilities. DigiGroupSetup: This program allows convenient Duplex system setup for any UR92 on ...

KB272 Is the DT 200 compatible with newer sets?

Is the DT 200 compatible with newer sets? The DT200 (now discontinued) was supplied with the Digitrax Big Boy starter set. The Big Boy system consisted of a DB100 configured as a booster, LA1 or LA2 LocoNet Adapter interface, DT200 throttle, and a power supply. The primary DT200 throttle also acted as the command station. The Big Boy system had full LocoNet capabilities. Unlike the Chief, this set depended on the DT200 as part of the of the system, with the throttle acting as the command station for the unit. With other LocoNet systems, such as Super Chief, it will ...

KB1022 Zephyr Xtra DCS51 Messages

DCS51 Messages Oooo              Short circuit shutdown -br-                DCS51 is set up as a booster BuSY              DCS51 is in programming mode and another command was issued before the first completed (press "EXIT" key) -cS-               DCS51 is powering up as the command station cccc               Current overload (too many locomotives in power district) dir                 DCS51 is in programming mode (press “EXIT” key) d nd              Open circuit on programming track (programming mode) d nA              No acknowledgement from decoder (programming mode) d nr               Not able to read decoder (programming mode) Er L               MU could not be set up (address already part of an ...

KB583 Programming output voltage and Bachmann decoder programming

Q:  I have a Digitrax Chief system. I wired the programming track as per the manual, using PROGA and PROGB outputs on the DCS100. I turned on the system and checked the track voltage with a Tony Trains RRamp meter, the mainline read 14.2 volts. The programing track did not read anything. I then checked the two wires coming from the DCS100 and they did not have any readable signal. A:  The programing track connected to PROG A and PROG B will NEVER have track power on except the very instant the program message is sent.  So, you would not ...

KB357 Headlights - Lamps or LEDs

Needs a comprehensive answer.  There may be one somewhere else already.  Z.This is from the decoder manual and does not answer the question:A 12 or 14 Volt lamp run directly without resistors will be less sensitive to voltage fluctuations. For regular 12 to 16 Volt lamps that draw more than 50 mA when lit, we recommend that you put a 22 to 33 ohm 1/4 watt resistor in series with the lamp leads. This will ensure that the lamp "start-up currents" (up to 10 times normal current draw) do not overload the outputs.If you want, you can estimate things by ...

KB193 Brake Sections

Braking sections are sections of track which will cause a DCC equipped locomotive to stop automatically. The simplest way to do this is to set up a track section where the power is turned off. This has two disadvantages. First, since there is no power, the locomotive lights will be off when the train is stopped in the section. Second, the lead loco in a consist stops as soon as it hits the dead section. Other locos in the consist will push the dead loco forward. In a long consist, you could get a situation where the last loco in ...

KB127 Slip Switches

The slip switch is a track element that has both a crossing at grade and also a set of movable points which allow trains to both cross another track and also change track.  The Crossing The crossing allows tracks to cross each other at grade.  The Slip SwitchThe more complex slip switch allows trains to both cross and to change tracks: In the schematic below, you will note that the slip switch is more compact than ordinary turnouts.  As a result, they are often found in high track density areas such as passenger terminals, where space is at a premium. ...

KB1046 Powering the DCS240

The PS615 is the Digitrax recommended power supply for the DCS240 in 5 amp mode.  For operations at 8 amps the PS2012 is the recommended power supply. When using the PS2012 special wiring considerations need to be used when powering both the DCS240 and legacy boosters from the same PS2012.  Leagacy boosters are defined as the DCS100, DCS200, DB150, DB200 or DB100.  Please see the separate article “Powering your DCS240 with a PS2012” and the additional notes below. The DCS240 may be powered either using the barrel plug connector or the screw terminals labeled “+” and “- “. The barrel ...

KB152 DS64 - Troubleshooting

The DS64 is a powerful stationary decoder. If you have tried to program this stationary decoder and are having problems, there are several things that you can do before contacting Tech Support for further help. Is the DS64 receiving enough power? The DS64 can be powered in several different ways. Although it is possible to power the DS64 from track power, this has been a source of problems for many operators due to low voltage. This typically arises on a railroad that is using power in excess of the capacities of its power supplies. Have you programmed all four addresses ...

KB914 MS100 Serial Computer Interface with USB Ports

The MS100 LocoNet Interface is a serial device that connects LocoNet to a computer via a 25pin serial port.This application note shows how you can use your Digitrax MS100 computer interface with the USB Port on your computer.  Serial ports are not available on most computers in current production. USB ports are more widely used today.  The Digitrax MS100 LocoNet interface can be connected to a USB port by using a USB to Serial RS-232 DB-25 Adapter Cable.  Digitrax recommends the PR3 for interfacing your USB equipped computer with LocoNet.Caution: Not all cables on the market will work. One that ...

KB92 Installation in a Walthers Trainline GP15

Our thanks go to Digitrax operator Aksel Suarez of Chesapeake, Virginia for sending this tip on how to install a Digitrax decoder in the Walthers GP15, called by some prototype railroaders a "Geepette" or "Cheep Geep". Use a DH165A0 decoder to replace the existing light board. Remove the plastic clips that hold the wires to the light board. Once the light board has been removed, place a piece of electrical tape on the metal frame to isolate the decoder from the frame and prevent a short circuit. The wires on the locomotive to the motor and lights do not follow ...

KB479 PM42 - Auto-Reverse Section Protection with Circuit Breaker Manager with a Single PM42

Q:  Can two sections of a single PM42 be configured to perform both the task of a circuit breaker and also automatic reverse section control for a single reverse loop? The PM42 can be configured so that one section of the PM42 is used for circuit breaker operation, feeding into another section of the same PM42 which is configured for automatic reverse section control. In the field, this configuration has been found to be unreliable in some layout configurations.  If you are having problems getting this to work in your setting, we recommend using an AR1 to handle the automatic reversing secion.  The ...

KB905 BDL162 - Increase Detection Section Threshold Sensitivity

How do I Increase BDL162 Detection Section Threshold SensitivityThe BDL162 has Option Switch settings to control detection sensitivity. The factory setting is OpSw19=t for a threshold sense for DCC occupancy of approximately 22 Kohms minimum. Changing OpSw19=c will set the threshold to 10 Kohm minimum. See the BDL162 instruction manual for details on setting the Option Switches. These settings will accommodate most layouts, though there may be circumstances when a higher threshold is desired, for example, in a high moisture environment or with G scale operations outside.To raise the threshold even further resistors can be added into the wiring between ...

KB968 Common Rail Track Detectors With Digitrax

We have a number of customers who are running Digitrax alongside their existing block detection circuitry. There are numerous block detection schemes and circuits, and we cannot cover all the variations here. Generally, it is necessary to isolate the block detector power supply and ground system of your existing block detector system from that of the Digital boosters. The most common detectors use "back to back" high current diodes to sense block current-draw. Detectors with "opto-isolated" or relay outputs will generally have no problem sensing current draw of a loco, etc., on the DCC current, and will signal the occupancy ...

KB578 Using MRC RailPower 1370 with Zephyr Xtra Jump Ports

Q:  I have an MRC RailPower 1370 DC power pack.  I was wondering if that would work as a jump throttle on my Zephyr till I get my UT4 LocoNet Throttle? A:  We think that the answer is "No", but you will need to verify whether this power pack produces pure or pulsed DC power directly with MRC. Throttles used with Zephyr Xtra via the Jump Port must produce pure DC power, often referred to as "smooth" power packs. Many "advanced" analog power packs use automatic pulse injection to make model locomotives run better at slow speeds. This uses 1/2 wave AC ...

KB978 DCC "standard" or "recommended practice"?

The NMRA's definition of Standards, Recommended Practices and Data Sheets.An NMRA Standard: "As charged by the NMRA CHARTER and CONSTITUTION, NMRA STANDARDS provide the primary basis upon which interchange between equipment and various North American Scale model railroads is founded. Under this requirement NMRA standards include only those factors that are considered vital to such interchange. For less critical matters see NMRA RECOMMENDED PRACTICES"NMRA RECOMMENDED PRACTICES: "The RECOMMENDED PRACTICE category was established by the NMRA Board of Trustees in January 1957, to "a. Promote maximum interchange between and within units. b. Specify the details of major components to improve design ...

KB675 Resetting a mobile decoder to factory settings

Most Digitrax mobile decoders have a global reset function, which returns the decoder's CVs to their factory default settings.This is useful if the CV values in a particular decoder have been changed with less than wonderful results. For example, you may have accidentally set the CV value for acceleration so that the engine won't move for minutes when issued a speed command. This makes it look like the decoder is not working when all it needs is to have the CV value for acceleration reset. Many of the decoders that are sent to us for repair just need to have ...

KB714 Loconet Overview

LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout.  LocoNet compatible devices are designed to work together on the network, and in some cases can also accept DCC commands from  the track, but often go beyond the scope of simple DCC train control.   LocoNet is a peer-to-peer Ethernet type multiple access network.  Because of its design architecture, it is very robust and powerful.  Layout implementation is simple and wiring is free form with minimal limits. LocoNet is designed to run an unshielded 6 conductor ribbon cable.  Digitrax recommends using flat, six-conductor telephone wire ...

KB226 Electrical Paths in older locomotives

I have an older Rivarossi Heisler that I have just installed a decoder in. I have 2 other Rivarossi engines, older, with decoders in them and they work. I use them as a template. Anyway, I can't get the Heisler to run. I have the orange wire at one side of the motor and the gray at the other. The red is soldered to the frame and the black is connected to the front screw where I disconnected the light etc. I just soldered the wires together. The motor is OUT of the frame so no short can happen. Can you ...

KB104 DB150 Control Panel

The front panel of the DB150 Super Empire Builder has electrical connection points, indicator lamps, LocoNet connections and toggle switches which give status indications, configure and connect the unit for your railroad. Power Input The two “POWER IN” terminals on all Digitrax boosters & command stations are the power input connections. Please see the related articles about power requirements for the DB150. Power Supply Digitrax recommends the PS515 power supply to power the DB150. There are many other transformers and power packs that can supply the input power for the DB150. Check with your Digitrax dealer for suggestions. Most regular ...

KB895 Digitrax Decoders with AC motors and "Lionel" Type E Units

Using Digitrax Decoders with AC Motors and Lionel Type E UnitsThis application note shows how Lionel users and other users of AC motors can use DCC to run their layouts.This example shows a wiring diagram for an AC universal motor with two-wire field coil. For this type of motor you must add a bridge rectifier to control the polarity to the motor's field coil.  This type of motor is found in AC locos built from the 1950s through today.Some Lionel type AC locos have motors with three wire field coils and an E Unit.  Half of the coil is used ...

KB972 PM42 Usage On A Non-Digitrax DCC System

If I use a non-Digitrax compatible system, what features of the PM42 Auto reverse/Short Circuit Managers (SCM) will I lose?The PM42 can be used as a stand alone Auto reversing unit and Short Circuit Manager with many other non-Digitrax systems, but for systems without LocoNet capability a number of networked management features will not be available.For example, the PM42 sends out real-time, event driven (non-polled) information to the LocoNet about fault problems and resolution, auto reverse actions and also identifies the affected sub-districts. This allows other devices, such as PCs, the Digitrax Signaling system, Digitrax Transponding or other detection and ...

KB697 TF4 - Programming Address, Function Mapping, Configurable Strobe & Effect Rate

Program the TF4's Address & Function Outputs1. Before using your TF4, set its address. This may or may not be the same address as a mobile decoder already installed in the loco or car depending on how you are planning to use the TF4. In the case of TF4's being used as a stand alone transponder or as a function decoder, choose an address that is not the same as another mobile decoder address in use on the layout.2. Connect the RED & BLACK wires of the TF4 to a service mode DCC programmer and program the TF4's address as ...

KB885 Wired Decoder Installation for Athearn Locomotives

This installation covers how to install a Digitrax decoder with wires in any Athearn HO locomotive.  Use either our DH123 (headlight functions only) or DH163 (headlights plus additional functions) for this installation.*** Note: This installation is based on installing a Digitrax wired decoder in an Athearn Dash 9-44CW. The process is similar for any Digitrax mobile decoder with wires. The instructions are also easily applicable for any Athearn locomotive.These instructions assume that you have already run the loco and have established that it is working properly before beginning installation. Remember, installing a decoder in a locomotive will not improve its ...

KB596 Automatic Reversing and Turnout Control

Q: How do I use the AR1 and automatically control the turnout? I'm confused here. It is good that the AR1 controls the switching of the track power for a reverse loop automatically but it seems the turn out direction also needs auto control. Am I missing something here? Need help understanding...Please explain. A: The AR1 is handles correcting the track polarity mismatch when a reversing section is encountered by a locomotive. When the polarity inside the reverse section does not match the polarity outside the reverse section, the AR1 detects the short circuit and flips the polarity so that ...

KB84 SE8C - Initial Setup & Testing

We recommend testing your new SE8C prior to installation on your layout. The following testing procedures will help familiarize you with the general operation of the SE8C. Track power needs to be ON, a working LocoNet connection and a throttle or PC running DCC control software. Pre-Installation Set-Up 1. Solder one wire from a 12V AC or 15V DC power supply to Pin 3 and the second wire from the power supply to the Pin C on the 44-Pin edge connector; this powers the SE8C. Digitrax manufactures the PS14, which is appropriate for this installation. Multiple SE8Cs can be powered ...

KB1019 OPS Mode Programming Sound Decoders - Tsunami, ESU, BLI etc.

OPS Mode Programming Soundtraxx Tsunami Sound Decoders      This article was originally written for Soundtraxx Tsunami decoders.  It will also work for other manufacturer's sound decoders.   The individual CVs that make up an address will need to be programmed individually. These CVs are AD1, CV17, CV18 and CV29. AD1 is the Primary (short address) Default 03, Acceptable Values 1-127 CV17, CV18 are the two CVs that make up the Extended (long address), Acceptable Values 128 - 9983 CV29 is for Decoder Configuration. Values are 06 for 2-digit and 38 for 4-digit addressing. There are many other values that ...

KB184 Mobile Decoder Naming Convention and Decoder Numbers

Current production Digitrax decoders use the following numbering system: The first character means that it is a digital decoder. This is always a “D”. The second character indicates the decoder’s physical size. This is based on the smallest "scale" the decoder is designed to fit. This will be a Z, N, H, or G. The third character is the current rating of the decoder. This will be a 1, 2, 3, 4 or 5. We designate 1.25 & 1.5 amp decoders as 1s and 3.5 amp decoders as 3s for simplicity. The fourth character indicates how many functions, including directional ...

KB296 SFX004/SFX006 Installation Instructions

Note the SFX006 is identical.  These instructions pertain to both Soundbugs.   1) Identify the correct orientation and mounting side of the DH165 series Decoder with SFX004 Soundbug Socket to plug this sound module into. There is text saying "SFX here" etc,. The SFX004 must only be mounted from the correct side and orientation, for each of the DH165 host decoders. 2) With correct orientation noted from step 1, align the dual row of SFX004 connector pins to the matching holes in the DH165 host PCB. Apply gentle and firm pressure behind the SFX004 connector to engage the pins until ...

KB979 Locomotive Sockets and Plugs for Decoder Installation

The NMRA has already adopted a set of recommended practices for standardized sockets and plugs in N, HO, and Large scales. Many new HO locomotives are being made with this socket. Any command control manufacturer is free to make a decoder or other device that will plug into this socket whether it is a DCC decoder or not. In addition Digitrax makes board replacement decoders for many HO models to make installation even simpler.The N-scale socket and plug arrangement that was adopted is based on a European design that works well for many European locomotives.  Unfortunately, this design does not work in some US ...

KB284 I tried to program an SFX0416 with my PR2 and the sounds did not "Take".

Q. I tried to program an SFX0416 with my PR2 and the sounds did not "Take". I clicked the big green "Program" button and after the initial buzzing for about 15 seconds, nothing further happened and now the unit makes no sounds. I am using a Compaq XP-home 1.5GHz laptop with SoundLoader version 1.16. How can I fix this? A. The most likely issue is that you are using the earlier SoundLoader version 1.16, which was not configured for full support of 16M bit flash sound memories, such as those used in the recently released SFX0416. SoundLoader was updated in ...

KB871 Keller SU1990 Sound Unit with Digitrax Decoders

You can easily control sound units like the Keller SU1990 by using the function leads on Digitrax Decoders and DCC command station that can control decoder functions. These instructions for connecting a Keller Engineering Diesel Sound unit to Digitrax DH83FX & DH140 series decoders was writtne many years ago.  Any modern Digitrax decoder with 4 function leads can be used. Equipment Needed:1) A Digitrax Throttle, Booster/Command Station or other DCC command station capable of controlling decoder function outputs.2) Any Digitrax decoder with at least 4 function leads will work here.3) The locomotive you wish to convert, be sure to check the ...

KB616 HO layout and 8 amp boosters

I was planning on purchasing the Digitrax Super Chief Radio 5 amps but several members in the club told me to buy them Super Chief Radio 8 amp for my HO Layout.  They said you will need the power when you start expanding.Question:Is it ok to use the 8 amp version for my HO layout?Answer:Yes it is fine to use 8 amp Digitrax boosters on your HO layout.  The choice between 8 amp and 5 amp command station/boosters, it is a question of how much power your railroad is likely to consume on your railroad as it is built today.  ...

KB938 Programming with UT2 & DB150 Genesis II

  To use the UT2 to program a decoder you must first put the UT2 in Programming Mode. To do this press and hold “RUN/STOP” and simultaneously press “PROG”. The Status LED will now turn a steady orange color indicating the UT2 is now in Programming Mode. Set the locomotive you wish to program on an isolated programming track (See Section 5.2). Make sure that the DB150 command station is not connected to any other part of the layout. If you don’t have a programming track on your layout remove any locomotive you don’t want programmed at this time. Decoders ...

KB57 BDL168 - Connecting to a "Common Rail" Wired Layout

Common Rail Wiring Many older model railroads use Common Rail wiring because they were initially wired to operate with electrical toggle switches. Conversion to DCC is possible with Common Rail, but it is not recommended. Whole layout common rail is a method of wiring layouts where power districts and their boosters are electrically connected using a common rail or common power bus return wire. Whole layout common rail wiring is a disadvantage when it comes to detection systems since detectors cannot independently monitor whether zone power is on or off so they can't tell whether occupancy detection is working in ...

KB1065 Clarifications of UR93 and DT602D/UT6D Duplex RF and network performance

Clarifications of UR93 and DT602D/UT6D Duplex RF and network performance: The new UR93 and DT602D and UT6D throttles employ the new Digitrax designed and manufactured RF28 Modular Certified 2.4GHz transceiver module. The RF28 is configured to interoperate with existing Digitrax Duplex UR92 LocoNet access points and e.g. DT500D and UT4D throttles worldwide. All Duplex units employ IEEE 802.15.4 PHY/MAC compatible devices using 2.4GHz Direct Sequence Spread- Spectrum (DSSS) modulation. The RF28 was developed for: a)  Smaller size. The venerable RF24 could not fit in the small UT6D, and this case was designed in 2017, so a new smaller Duplex support ...

KB590 Q&A - Powering DS64

  Q:  How do you connect more than one DS64 to a single power supply like a PS14 to power them or do you need a separate power supply for each DS64? A:  One power supply can be used if it can provide adequate power for all the DS64s it is powering. The PS14 has a built-in circuit breaker; when it exceeds its capacity, it will shut down, cool off and then start up again. If you are experiencing this behavior then you need to add one or more PS14s to provide enought power for the DS64s you have connected. Our recommendation of one ...

KB82 DS64 - Railroad Control Panel Indicator Lights

I'm looking to wire Tortoise switch machines on a DS64. When the track switch is thrown I want to power 1 color light (non-LED). When the track switch is closed, power a different colored light. Is this possible using the DS64 inputs or the Tortoise connections? The DS64 does not have separate connections for indicator lights for trackside or for a control panel. However, indicator lights can still wired to work with the DS64. Tortoise or other slow motion swith machines can be wired in two different ways. If using LEDs, a two leg, bipolar LED can be connected in ...

KB97 Athearn N-Scale FP45 / F45

What Digitrax decoders work in the new Athearn N scale FP45? We recommend the DN163K1C, following the procedure below. One of our editors was able to successfully install both the Digitrax DN163K1B and DN163K1C decoders in the unit. We have determined that the chassis design requires that the decoder be installed backwards. The only problem this poses is that one additional step has to be taken when programming. Both the DN163K1B and DN163K1C decoders are the same footprint with the exception of the LEDs. The DN163K1B has T-1 3mm LEDs and DN163K1C has surface mount LEDs. When the K1B version ...

KB69 Nemo Junction - Connecting BD4 to the SE8C

BD4 Output Each BD4 is situated between the PM42 Power Manager and the railroad. The DCC signal passes from the DCS50 Zephyr, through the Power Manager, through the BD4 to the track to the locomotive. When a locomotive (or equipped car) is present in a track segment, the BD4 also sends out occupancy information, in two ways. Occupancy Information Output LED1 The LED1 10-pin header is for testing the status of power to the rails and block occupancy with the LED indicator which is included with the BD4. The LED1 can also be used for panel indicator lights using LED's. ...

KB737 DT402 & DT400 Series Throttles - Recalling a Locomotive

DT402 & DT400 Series Throttle-Locomotive Recall The DT402 & DT400 Series Throttles store the last 4, 8,or 16 unique loco addresses used by the throttle in a recall stack; your throttle defaults to a 4 address recall stack.  Users often discover this feature when taking their throttle for use on another Digitrax railroad; they plug their throttle into the new LocoNet and discover their own locomotive addresses are still in their throttle.  The presence of stored locomotive addresses may make operations on your railroad easier.For example if you have your throttle set up for an 8 deep recall stack and the last 8 ...

KB468 Zephyr - Consisting Tail to Tail

Q:  I'm wanting to know how to MU two locomotives together that are in a tail to tail configuration. I know that this can be easily done with a DT400 or DT402 throttle but not sure how to do it with the Zephyr. A:  Make sure all the locos in the consist are traveling in the same physical direction on the track (both going to the left or to the right). Remember that "reversing" takes place in the locomotive not on the track, so it is important that the engines be traveling in the same direction when they are MU'd.  ...

KB520 General DCC Power Supply Information

There are many transformers and power packs that can supply input power for Digitrax boosters & command stations. Most regular DC train control packs do not have enough power to supply the full power potential of the a 5 or 8 amp booster, since they were designed to only run 1 locomotive in a blocked system. To get the full power potential of your booster, you must use a power supply that can supply enough power. Check with your local Digitrax dealer to see which transformers are available. If you are using a Zephyr Xtra, please use ONLY the power supply ...

KB1017 LocoNet Accessory Power Requirements

  This document outlines the power requirements for Digitrax LocoNet accessories.  To simplify wiring, Digitrax recommends providing individual power supplies for like accessories.  For example a power supply or power buss which only powers the PM42s.  A power supply or power buss used solely to power multiple DS64s.  UR9x and UP5 panels can be daisy chained provided adequate current is provided to properly power all the panels.  Through the use of individual power supplies, the chance of Ground Loops or sneak paths back to ground is minimized.  Using individual power supplies will also make troubleshooting much easier.  Many Digitrax LocoNet ...

KB71 DPDT - Double Pole Double Throw Electrical Switch

What is it and how do I find a DPDT?It's an electrical switch; double pole - double throw (DPDT). Here is a schematic of a DPDT: More typically, they look like this: The DPDT is very common to model railroading and found at just about any store that sells electronics.  It comes in a variety of arrangements, with the most common being a DPDT Center-Off switch.  Analog OperationsIn the early days of Direct Current model railroading, reverse loops had to be controlled by hand, and the DPDT was perfect for the job.  The DPDT was wired in such a way ...

KB185 Common Rail Wiring and Converting the Clinchfield

I'm helping a friend rewire an existing layout from analog to digital. You might be familiar with the layout, it is the original Clinchfield layout that Model Railroader built back in the late seventies, believe it or not. The layout, of course, is blocked for analog through DPDT switches which have been eliminated. I was able to repair the wiring back to original using the drawings that MR printed. The layout uses common rail wiring, this is what I have to work with, and to rewire using home run wiring would be a MAJOR rework, not doable. I was able ...

KB849 Zephyr - Jump Ports-Using DC Power Packs as DCC Throttles

DCS50’s Jump A & B ports can host two DC power packs that work as additional throttles to control DCC locomotives.You begin with an operating DCS50 attached to your layout.   In addition to the throttle built into the DCS50, you can create a LocoNet to add additional Digitrax throttles and other Digitrax devices.  Jump Ports:You can also connect up one or two smooth DC power packs as shown in the following illustration.  These power packs must also be powered, since the Zephyr jump throttle connections detect the voltage level from the individual power pack(s) and makes adjustments to the command control ...

KB929 Speed Steps Explained - 14, 28, 128

Most modern command stations and decoders are set up to run 28/128 speed steps.  If you are using older command stations or decoders you may need to adjust one or the other to get the trains to run.Why are more speed steps better?The reason you want to use a command station and decoders with 128 speed steps is for smoother speed control of your locomotives.   Digital command control signals are just that, digital.  When you send speed commands with your throttle, you are sending digital instructions telling the decoder to change from the current speed to a different speed.  When ...

KB54 BDL168 - Troubleshooting Checklist

Here are several things to check if you are having trouble with the BDL168: Proper Wiring Be sure that you have NOT connected pin 11 to pin M, as this can prevent proper LocoNet communication. Check to make sure not wires are touching adjacent pins.  Follow the wiring diagram closely. Packet Reception Be sure the green ID LED is ON & is “winking” off about every 2 seconds. This means that correctly formatted DCC packets are being decoded from the left most (Railsync) pin of the RJ12 LocoNet socket. For DCC detection, the same DCC packet signal that drives the ...

KB402 Is having back-EMF more "dangerous" to the motor?

Scaleable speed stabilization (back EMF) compensates for load by providing more voltage to the motor.  If there is a mechanical problem with the locomotive that greatly increases this load you can prevent damage to motor by setting CV57 to limit how much throttle can be added due to BEMF.Digitrax Scalable BEMF uses CV57 to control how much compensation authority the BEMF control loop has.  The higher CV57 is (0-15 range) the more back-emf the control loop can crank in; a value of 0 effectively turns off BEMF compensation.  The value in CV57 takes into account the different throttle levels as ...

KB208 Case Study: Texas & Southwestern Part 2 of 11 - Background

With this section, we will talk about the practical realities of building a model railroad with DCC. We chose Dallas, Texas as our locale, in part because so many great model railroaders came from Dallas, names that may not be familiar to you but people who helped make the hobby into what it is today. Texas is big; any Texan will tell you so. But even when allowing for Texan pride, the ordinary outsider develops an appreciation for Texas size. From the piney woods of Lufkin in the east to the rough mountains of Big Bend, from the high plains ...

KB305 Programming CV17 & CV18 (four digit addresses) manually

Some DCC systems need to have CV's 17 and 18 programmed separately to assign the decoder a 4 digit address.Digitrax command stations handle this automatically by default.  If you have a decoder that needs manual entry of CV17 & CV18, follow these steps:You cannot simply split the four digit address in 2 halves and input these into CVs 17 and 18. A conversion from decimal numbers to hexadecimal numbers is required. Once the hexadecimal conversion for the 4 digit address is performed, this number is then split in half and then each half is input into CV17 and CV18 respectively.To ...

KB301 Speaker Mounting

Speaker Mounting and baffle/enclosures. The sound performance of any attached speaker(s) is greatly affected by the mounting system and required baffle or rear enclosure. The baffle is used to isolate to speaker diaphragm front sound waves from the out of phase rear sound waves. This minimizes sound cancellation, particularly at lower frequencies. For most efficient sound generation, the volume of the baffle should be as large as practically possible, and the baffle walls should be acoustically rigid so not to allow acoustic interference. Practical baffle materials are plastic, cardboard and even sheet metal. Common items such as cardboard tubes or ...

KB941 CV49, CV50, CV61 - Setting Up Configurable Strobes

Configurable strobes are set up using CV's 49, 50 and 61. Configurable strobe function leads can be programmed with a limited number of simulated lighting effects similar to FX effects but without as many options. Configurable strobes are offered in those few Digitrax decoders where there was not enough "code space" to provide full FX features.CV49 controls F0 Forward, the white function lead. CV50 controls F0 reverse, the yellow function lead.CV61 enables the configurable strobe operation.To set up configurable strobe lights:1. Program CV61 with the CV value "01" to enable configurable strobe operation.2. Program the CV value for CVs 49 ...

KB96 DB150 Slot Management for 22 Addresses

The DB150 has 22 “Slots” for locomotive addresses The DB150 command station can run up to 22 loco addresses and throttles at a time. Each of these addresses occupies one of 22 “slots” available in the DB150’s memory. Once those 22 slots are full the system will display the “slot=max” message to let you knot that you need to release some locos if you want to select and run others. The DB150 manages the addresses that occupy slots by assigning different statuses to each decoder depending on how it is being used in the system. This allows the DB150 to ...

KB469 Locomotive not included in Decoder Selector

Q:  I have an HO Bachmann Alaska EMD GP40 (Bachmann item #63548) that I have kept in the box for about a year. I recently received a Digitrax Zephyr and I want to put a decoder in the locomotive. I used your reference guide and did not see it listed. Does that mean it's not available? A:  There are many reasons why a particular locomotive is not listed in our database.  The most common is that we have never been asked about that particular model.  There are so many new models it is a difficult task to keep up with ...

KB920 Installing Semaphore Type Signals with SE8C

How do I set up the SE8C to control semaphores? Installing Semaphore Type Signals with SE8CThe SE8C can be set up to use its 8 turnout motor drive outputs to run 8 three-position semaphore (arm type) signals using slow motion turnout control machines (such as the TortoiseTM machines) as actuators. These 8 semaphore signals are available in addition to the standard 32 LED signal heads on the 8 signal control cables and occupy a separate semaphore address control range.The SE8C automatically sequences the three possible mechanical arm positions to match 3 aspects of red, green and yellow using a position ...

KB183 Speed Tables

A speed table is a list of numbers, one number for each speed step. Many operators customize their locomotives by adjusting the CV's for Vstart (02), Vmid (06) and Vmax (05) to set the throttle response characteristics for each locomotive. This is known as a three-step speed table It is also possible to create a more complex speed table, either with 14 or 28 steps that specify the exact percentage of full power sent to the motor when the throttle is set to that speed. Speed tables can be set up for 14 or 28 speed steps, but not for ...

KB259 DH165L0 - Installation Instructions

DH165L0 fits Life-Like GP7, SD60 and many other locos with Life-Like DCC medium plug arrangement. 1. Remove locomotive shell, noting the orientation of the circuit board inside. (See Figure 1) 2. Unplug the the manufacturer’s DCC socket from the pins on the factory board. Remove the two screws that hold the board in place. (See Figure 2) Lift out the factory board and save the two screws for future use. 3. Insert the locomotive’s DCC socket onto the pins on the Digitrax DH165L0 decoder board. In this orientation, Pin 1 (the orange wire) is the lower left pin and Pin ...

KB1063 IPLing and Track Power with the DT602/D

IPLING From time to time the latest DT602 family throttle firmware will be updated and will be posted on the product support page.  These updates may slightly modify the DT602's operation, based on customer feedback/requests and priority support issues discovered. If you are happy with the operation of your DT602, and have no issues or new features you may want, it is not required to perform an available update. All DT602 family throttles should only be firmware updated or IPL'd while plugged directly into a working LocoNet. The Digitrax provided DMF file for field updating DT602's can be used for IPL of any ...

KB285 Mars Light in a Proto 2000 PA-1

I'm trying to install a DH123D decoder in a Life like P2K PA loco and make the mars light work. HELP! Because the DH123D is a two-function decoder (front headlight, rear headlight), it may not be the best decoder choice for this locomotive. In practice, some PA's had only one headlight, thus there would be no Mars light. The DH123D would be an appropriate choice for those locomotives. Typically, eastern railroads would just have one headlight; think Pennsy and Southern Railway. Western railroads, because of higher train speeds, often used warning lights such as the Mars Light or Pyle Gyra-Light; ...

KB875 Lenz Systems Using Digitrax Boosters

You can have the power and reliability of Digitrax boosters even if you use a Lenz Command Station. You can use Digitrax boosters to automate reverse loops, too. Digitrax boosters can be used with the Lenz Command Station to provide more power for driving the layout. Many customers are using DB150, DB200, or DB100 series boosters instead of LV100's because the DB150’s & DB100's are very reliable 5 amp boosters with plenty of heat sinking capability to prevent heat related booster shutdows. Equipment needed: 1) A Lenz LZ100 Command Station. 2) A DB150, DB100 or a DB200 series booster. 3) ...

KB393 DS64 with Yard Ladder & Manual Route Buttons

  Simple Example of a Yard Ladder with Manual Route Buttons in a hidden yard. Set DS64 OptionSwitches 11 and 15 to 'c' closed to enable route commands from local inputs. Make sure the momentary-on push buttons are wired as shown in Fig.1 above. OPSw 11 enables the local inputs to trigger the routes stored in the DS64. A1 will trigger route1, S1 will trigger route 2, and so forth. OPSw 15 prevents the local inputs from directly triggering the outputs.Option Switch Configuration Press the OPS button on the powered DS64 for about three seconds until the red led begins ...

KB866 DZ121 - Compatibility with Easy DCC, MRC or Lenz

The DZ121 was discontinued in 2002.  There were some interoperability issues with Easy DCC, MRC and Lenz.  The exchange offer is no long valid.  This article is still published for reference only.At that time, Easy DCC, Lenz and MRC users could return DZ121's to Digitrax for no charge replacements that will work on their systems. There was no reason for Digitrax, Wangrow or NCE users to replace any DZ121 decoder unless they wre having problems.The text at that time:For Easy DCC and Lenz users who are having problems: To determine whether your DZ121 should be returned, read back CV07. A ...

KB275 DT400 Problems with DCS100 and DB150

Q: I connect my DT400 to my DCS100 and it works fine, but when I add a DB150 working as a booster the DT400 stops working. What is wrong? A: A number of things may cause this, so you can use the diagnostic features of the DT400 to solve this problem. Experience has proven that the most common LocoNet problem is related to pins 3 and 4. By following this diagnostic procedure, you can narrow down to the source of the problem. Starting with DT400 without a battery [The throttle has no battery for this test to assure it executes ...

KB663 DT300 - Option Switch 2 (Op#2)

The factory setting for the DT300 is Op#2=x23 with 128 step decoder setting and IR (infrared) tetherless operation enabled.The factory setting for the DT300R (radio) is Op#2=x03 with 128 speed step decoder operation and tetherless operation for both radio and IR enabled.Throttle Default Decoder OperationEach DT300 can be set up to operate new decoders selected by them as any decoder status code you choose. New decoders are defined as decoders that have not been selected in your system. Your DT300 is set to expect to operate mostly decoders that are 128 speed step capable, so when a new decoder is ...

KB219 Sound Project Files-Creating and Editing

With Digitrax Sound Definition Language, you can use .wav files to create custom sound project files. The process of converting 'raw' sounds recorded in the field into a sound project file takes time and patience to produce a finished sound project file that sounds realistic. Tips for Recording Locomotives and other Sounds Recording the sounds is a major part of creating great sound projects.  You need good recordings to work with.  Record several complete sound events (several complete whistle blows from start to finish, etc.). This will give you several recordings to choose from when editing to produce your sound ...

KB772 DT400 Throttle Overview

The DT400 and DT400R are full function hand held throttles that include 2 independent throttles and a common keypad to control up to 13 functions (0-12), turnouts and programming.The DT400 offers wireless infrared remote operation used in conjunction with a UR90 or UR91 Receiver Unit.  The DT400 requires a 9 volt battery for infrared operation; the DT400 does not require a battery in normal walkaround operation. If you do not install a battery, the throttle display will be off while you are unplugged from the system. The DT400R offers wireless radio remote operation when used in conjunction with a UR91 ...

KB416 Case Study: What do I need for a small layout in a 10' x 10' room?

I am a 'newbie' to model railroading.  I have a 10' x 10' room put aside for my layout which will be basically a U or horseshoe shape going around three of the walls.  I am using Atlas code 55 in N scale. Since I'm starting from scratch, I want to do it RIGHT and that is why I've decided to buy DCC straight away. I want to run a maximum of 4 trains at once. I would like the capability of having two users (drivers) operating at the same time, but I want to manually set turnouts. I will ...

KB913 Adding Radio or IR

Adding duplex radio, infrared or simplex radio to your existing Digitrax system is simple because of LocoNet.InfraRedYou probably already own a DT300, DT400, UT4 or DT402 series throttle. All of these are "InfraReady." These all come with two IR emitters pre-installed. All you have to add for IR operation is one or more UR90 Infrared Receivers to your layout. Most layouts require multiple UR90s because the infrared signal is line of sight. This means that your receiver will need a sight path to the throttles.Simplex RadioDigitrax throttles with an "R" at the end of the part number are simplex radio ...

KB168 Layout Lighting and DCC

What's the best method to handle structure and street lighting with a DCC layout? If I put in bus wiring for my lighting can it interfere with the DCC signal? Unless you have stationary decoders that control the structure and street lights, there is no need for connecting these lights to your DCC wiring. In fact, doing so will add additional power consumption without any of the advantages of command control. These additional power consumers take away available power for your locomotives, controlled cars and stationary decoders. Should I use a completely different power source like an old power pack? ...

KB170 PR3 - Computer Requirement Update

Will the PR3 and SoundLoader software work on systems with specifications other than those listed in the PR3 manual? The beta testers have reported that the PR3 with SoundLoader software, DigiMon software, and IPL software have been found to work on many desktop and laptop computers running Windows 2000 and Windows XP with Processors as slow as 450mhz, Ram memory as little as 128mb, and USB 1.1 Ports. The beta testers cannot confirm that every computer with the above limitations will function properly with the PR3 and SoundLoader software.

KB290 What are FX Functions?

Many locomotives feature warning lights that are designed to make a train more visible to the general public. FX Functions are function outputs that incorporate 4 FX generators for prototypical lighting effects such as Mars lights, ditch lights, Pyle Gyra-lights, rotating beacons, single and double pulse strobe lights, and random flicker.

KB339 Reading back manufacture codes

I have a Zephyr and a DT400 throttle. My locos have chips of various manufacture. Is there a method, without dismantling the loco of reading which chip is fitted in it? Well, we can't speak for other manufacturers, but if you take a look at the Digitrax decoder index, you will note that many Digitrax decoders have a Manufacturer's ID of "129". This is found by reading the value of CV#8. Some other manufacturers also use Manufacturer's IDs, and you will need to consult their documentation for this information. Note: CV08 is also used to reset Digitrax Series 3 decoders ...

KB410 GG1 Juice Jack Sounds

Can the SoundBug sound like a juice jack, i.e. a GG1? Yes. The SoundBug, like all Digitrax Sound FX decoders, can be set up with any available sound project. Any recorded sounds can be set up as a sound project file (.spj) which relates the sounds to individual actions of the locomotive. Many project files are available on the Digitrax Sound Depot and on the web.  Sound projects are free. 

KB603 Zephyr - What components are needed to wire a reverse loop?

Since many Zephyr and Zephyr Xtra Starter Sets are used on smaller railroads, a natural choice for setting up an automatic reversing section would be an AR1. If you have more than one reverse loop, then the PM42 is a better choice. These automatic reversing strategies will work equally well for any Digitrax system using any Digitrax Starter Set.  Alternately for larger railroads, an auto reversing booster such as the DB150 can be used for automatic reversing if the section is large.

KB946 What does the "DCC symbol" mean?

Companies that sell interoperable equipment compatible with the NMRA's DCC "Standard" often use the DCC logo to let customers know that they support basic DCC standardization by producing DCC compatible equipment.This symbol is seen on many DCC compatible products because the NMRA DCC "Standards and RP's" do not cover all DCC compatible equipment and therefore not all DCC compatible equipment is eligible for a conformance seal. Basically, command stations and decoders are covered by the "Standards and RP's". Throttles (or cabs), computer interfaces, boosters (or power stations), computer based programmers, cab buses, control buses, control networks, radio and infrared interfaces, ...

KB670 Configuration Variables and Factory Default Values Used By Digitrax Decoders

This is a list of all configuration variables (CVs) and their factory default values in decimal and hexadecimal notation used by Digitrax mobile decoders.  Simpler decoders access only a few of these CVs, while advanced decoders access many, if not all, of these CVs.  

KB286 LocoNet Cable Connectors

Previously, we have recommended RJ12 connectors for LocoNet cables. While there have been online sources such as Digi-Key, Mouser and others, they have become harder to find locally. There now appears to be a easily available alternative. Many national big-box home improvement stores have RJ11 6P6C meaning they are 6 position 6 conductor and can be used as RJ12 although labeled as RJ11. These must not be confused with four conductor connectors since LocoNet has six conductors. You will need the connectors, the six-wire flat cable and a crimping tool. We paid $20.00 in February, 2008, for such a tool ...

KB932 CV29 - Configuration Register - Overview

CV29 is also called the Configuration Register.  It is a special CV that handles several different aspects of locomotive behavior.Characteristics Controlled by CV29:1.     Speed Step Control:  Advanced Mode (28/128 speed steps) or Standard Mode (14 speed steps).2.     Speed Tables: On or Off3.     Analog mode conversion: On or Off4.     Normal Direction of Travel (NDOT)5.     2 or 4 Digit Address selectionDetermining CV Value To Program Into CV29The numerical value value you will program into CV29 will affect many important decoder characteristics.  Each of these characteristics is controlled by a "software switch." This switch is either on or off depending on the CV ...

KB620 Signaling & Detection - Overview

The subject of railroad signaling is a fascinating one.  Signals provide a margin of safety and protect the train crews, freight and passengers on the railroad .  Grade crossing signals also protect the general public from collision with moving trains.  Signal operation relies upon three basic elements: Detection of trains   Operation of the signals   Operation Logic Signaling is a complicated topic, far beyond the scope of this knowledge base.  But Digitrax offers several items which will help you with creating a realistic signal environment. Detection determines the presence or absence of trains.  Both the BDL168 and BD4 will ...

KB818 LocoNet: The Digitrax Difference!

LocoNet System ArchitectureDigitrax LocoNet is a Peer to Peer local area network (LAN) designed specifically for model railroad operation.  System architecture is the biggest difference among DCC systems, the way the components of a DCC system communicate among themselves. LocoNet wiring is cost effective, flexible and expandable to accommodate almost anything you want to do with your railroad today and in the future.System ExpansionHere are some of the expansion possibilities available with LocoNet. With Digitrax LocoNet your DCC journey starts at the Main Station with your first “starter” set. From there, it’s up to you. You can add:  Mobile decoders ...

KB329 Route Basics

The Super Chief can be used to operate routes. A Route is a group of turnouts and their specified positions that will be triggered by the activation of a single "TOP" switch address to a specified position. The DCS100 Super Chief supports up to 32 routes. Each route consists of a list that contains a TOP turnout address and its position (c or t) and up to 7 other turnout addresses and their positions. Routes are stored in the DCS100's memory and can be operated by any throttle in the system that can send switch commands. Each of these 32 ...

KB957 Equipment Recommendation: 4'x8' Layout Running 2 or 3 Trains

I have a 4x8 layout, I want to run 2 or 3 trains. I will operate the layout by myself or with possibly one other operator. It's a really basic operation. Which Digitrax set is best for me?The Zephyr Xtra Set will probably do what you want. You will need the Zephyr Set and mobile decoders for the locomotives. You can connect up to 20 throttles to your Zephyr Xtra Set so that adding another operator is as simple as plugging in another throttle. You can also use one or two smooth DC power packs as throttles for additional operators to run trains ...

KB809 DS64 - Connecting Solenoid-type Turnout Machines

Once you have set up the DS64 to operate the type of turnouts you will use, the next step is to hook up the turnouts to the outputs of the DS64. Each type of turnout machine has specific requirements for wiring.Note: The DS64 is configured for either for solenoid turnouts (the default setting)  OR slow motion turnouts. Only one type of turnout motor can be used on any particular DS64.Note: Multiple turnout machines can be operated on a single DS64 output.For example, you can run 2 Peco or Atlas Snap Switches on a single DS64 output. Up to 4 Kato ...

KB844 Zephyr - Programming Error Messages

When you are programming decoders, there are a few error messages you may encounter.There are many causes for these error messages but most can be solved by checking the following:1. Be sure the programming track is connected properly to the DCS50.2. Be sure a decoder is correctly installed in the locomotive with all motor and pick up connections made correctly.3. Be sure the loco with decoder correctly installed is making electrical contact with the programming track and that it remains in contact with the programming track until programming is complete.  Check to see if the track is clean and the ...

KB441 Customizing the DT400 Option #3 - Recall Stack Depth

The DT400 recall feature can be configured to keep a list of the last 4, 8, or 16 addresses that were previously selected in the throttle. The number of locomotive addresses stored is determined by changing the values of Option 3 of the DT400; the default setting is 4. It is not possible to clear out the stored locomotive information held in the stack. Locomotives in the Recall Stack rotate out as newer locomotives are selected, usually on a FIFO (First In, First Out) basis, but there may be exceptions. For many users, searching the Recall Stack may complicate matters ...

KB836 Stealing A Locomotive Address

Stealing A Locomotive AddressDigitrax systems do not allow more than one user to select and run the same locomotive address unless the loco is “stolen” (or shared) by the new user. When an address is receiving commands from more than one throttle, it may seem to be out of control.Stealing is a safety interlock that prevents operators from automatically taking control of locos that are already selected and being run on another throttle. Occasionally you may need to override this interlock to gain control of a loco. This override is called stealing and will result in having a single loco ...

KB455 Route Basics - DCS100 or DCS200

You can use your DT400 series throttle with a DCS100 or DCS200 to set up routes that are triggered by operating a single turnout address to make it either c (closed) or t (thrown). Setting up and operating routes is similar to consisting locomotives because you can cause more than one unit to operate based on a single command sent to the system. We call the turnout address that other turnout addresses are “consisted” to, the TOP address. To operate a route, use Sw (Switch) mode to select the TOP turnout address in the route and move it to either closed or ...

KB621 Power Management Overview

Power Management is a concern on every layout.  With Digital Command Control, the main concern is that enough power is supplied to evey track section on the layout so that the digital signal is transmitted to the decoders in the locomotives and turnouts.Each locomotive uses power from the track, some for the motor, some for headlights and other functions and some for the command control electronics in each locomotive.  More electrical power is necessary to run more locomotives on the layout.  Digitrax boosters provide between 2.5 amps & 8.0 amps.  A small N Scale or HO Scale layout with two to ...

KB131 DCC Install in Bachmann Dash 8

How to add DCC to the new run of Bachmann DCC ready Dash 8-40CW? The current recommendation is for direct soldering, using either DZ125, which controls headlights only or DZ143, which controls headlight and two additional functions. With earlier units, either milling of the frame or a replacement frame was necessary, but the new units have a "DCC ready frame"; the source of this information also points out that Bachmann is using the same model number for both the older version and the newer version, so you should make certain that you have the recent version.

KB271 Zephyr as a Throttle

I have a Zephyr and a DB150. How can I wire the two together so that the Zephyr acts as throttle and the DB150 supplies power? At this this time I have only a single block. The easiest way to handle this situation is to divide the railroad up into two power districts. If one command station unit is more powerful than the other, then the area controlled by the weaker unit (in this case, the 2.5 Amp Zephyr) could simply be a single siding or engine terminal. The Zephyr would then become a booster, supplying power to this small ...

KB395 Turn Off Grade Crossing Horn Sequence in Locomotive

Q:  How do I turn off the grade crossing horn sequence when powering up or changing programming? A:  Turn F7 to "off"; it has accidentally been toggled to "on".

KB411 AR1 with BD4 for Block Detection

How do you wire an AR1 with a BD4 so that you get block detection within the reverse loop and without the BD4 permanently detecting the AR1? It should be wired with the AR1 between the power source and the BD4. All four detection sections of the BD4 will have to be inside the reverse loop.

KB506 Mars Light

Q:  I have a DH163D decoder. How do I program it so the Mars light works? A:  Any function output on Digitrax FX decoders can be set up for any FX effect by programming its associated FX CV to the appropriate FX CV value. For example, if CV52 (the FX CV for F2), is programmed with a CV value of 034, the violet wire F2 function output will be a Mars light when F2 is turned on for this decoder address and the decoder's direction is forward.

KB550 DS54 - Reset to Factory Default Values

Q:  How do I reset the DS54 CV's to factory default values? A:  Each DS54 CV must be manually reconfigured to set the DS54 to factory default values. The factory default values for the DS54's CVs are: CV01 = 1 All other programmable CVs = 0

KB554 Power supplies-Range of what works

  We need to re-write this to be general purpose describing how power supplies should be selected  -Z.Would a 12V, 500mA power supply work as a replacement for the 12V, 300mA power supply? Yes. It is much more power than the device needs, but it will work. The purpose of independent power for the UP5 is to serve as a “Battery Saver” for throttles connected to UP5.

KB558 AR1 with Two Power Districts

Q: I want to use the AR1 for a reverse loop between two different power districts (i.e. different booster for each connected track). Is this possible or do I need to make a special wiring set-up to do this? SThis diagram shows how to do this The usual rules apply, the AR1 track section must be longer than the longest train you will run.

KB585 Locomotive Orientation In An MU

Q:  How do you reverse the direction of the engine so you can run them on the same train with one in the backwards position?A:  Before consisting the locos, make sure that both are traveling in the SAME PHYSICAL DIRECTION ON THE TRACK.  The locomotives can be arranged in either orientation hood forward or backward as long as they are set to travel in the same physical direction when you set up the consist.(The direction indicators on the throttles may or may not match, the important thing is that the locomotives are set up to move in the same direction and are ...

KB608 Locomotive Throttle Response

Why do my trains start moving at 25% throttle?You may need to adjust some CV valuesCheck the value of CV02, start voltage; the default setting is 0 (zero).  You may need to adjust this value.Check the value of CV03, acceleration rate; the default setting is also 0.  It is possible that the locomotive has been set for a slow acceleration rate.You can also adjust how each locomotive responds to throttle inputs by programming loadable speed tables or 3 step speed tables.If you decide to reset the decoder to factory default values , set CV08 to a value of 08 to reset the decoder back ...

KB718 Sound Scheme Descriptions

I have loaded a new scheme but the CVs and Functions are not working as I expected. Load the sound project you programmed into Sound Loader.Select the "view>project description" from the menu.The text file that describes how the project you have loaded will appear on the screen.Read the text file to be sure the sound project is suitable for your needs.If not, load a different sound project and see if it works better for your application.  

KB826 Zephyr - Adding Another DCS50

You can add a second Zephyr to add more power and an additional throttle on the DCS50 and two additional Jump ports for using DC power packs to control DCC locomotives.  You will need to change Option Switch 02 to c (Closed) on the second (and any additional DCS50s you might choose to add to the layout as well).  The diagram below shows you how to do this.

KB873 Lenz LV100 Booster with LocoNet

Note: Upgrading to Digitrax from Lenz doesn't have to mean purchasing all new equipment! This app note shows you how to salvage some of your Lenz equipment when you move up to Digitrax!

KB874 Lenz LV100 Booster with Digitrax DT200 Command Station

Note: Upgrading to Digitrax from Lenz doesn't have to mean purchasing all new equipment! This app note shows you how to salvage some of your Lenz equipment when you move up to Digitrax!

KB973 Using PM42 With Other Systems

The PM42 was specifically designed to work with Digitrax Direct Home wired layouts. Any system that is configured this way will work with the PM42 with no interoperability issues. For example, CVP uses interoperable booster connections.The PM42 can be used with a DC system if it is hooked up in the negative ground return path, or even a Marklin AC digital (trinary) booster. It is possible for the PM42 to be used with most DCC systems. Digitrax has no control or knowledge of each specific non-Digitrax system and how it may interact with the PM42.

KB363 DZ123 in older Athearn Locomotives

Your Athearn example uses the DH123/143 series with the AT clip option, can the DZ123 be used for Athearn older diesels? I am interested because of the small space in S2/4 models. Is the 1 amp DZ123 an option I can use? It is possible that the DZ123 could be used in the older Athearn switchers, but the most important issue will be how much electrical current that the locomotive requires. If the locomotive's stall current is below 1 amp, then the DZ123 can be used. Otherwise, the locomotive motor will eventually, sooner or later, destroy the decoder by drawing ...

KB316 Loco seems uncontrollable

When I turn the throttle knob, my locomotive quickly changes speed in large increments.A very common common problem is the throttle "jumping" 3 or more steps each time the throttle is turned.  This simply means the system is not set for 128 Speed Steps in that particular address.Earlier decoders, and some less expensive decoders, were set up for 28-speed steps or even 14-speed steps; very early command stations were only capable of handling 28 or 14 speed steps.  Technology has marched on, and most modern systems now operate using 128 Speed Steps.When first turned on, Digitrax systems are set to ...

KB117 Notes on Kato HO-Scale Unitrack Turnouts

Kato recommends, and Digitrax concurs, that the best DCC performance with the Unitrack turnout requires that you set each turnout to "Non-power-routing". Kato has offered a variety of turnouts in their H0 Unitrack line.381-2840 - LH, 490mm Radius, selectable operating mode with power or non-power routing.381-2841 - RH  490mm Radius, selectable operating mode with power or non-power routing.381-2850 - LH, #4, power routing only. * Some additional power feeds required for use with DCC 381-2851 - RH, #4, power routing only. * Some additional power feeds required for use with DCC381-2860 - LH, #6, live or insulated frogs, power or non-power ...

KB719 Changing Between Pre-Installed Sound Schemes

Many Digitrax SoundFX decoders come with two different sound schemes pre-installed.  Check the decoder instruction sheet for which sound schemes are installed in the decoder you are using.  Instruction sheets are available on this website on the product pages for each decoder.The decoders come from the factory with CV60 programmed to a value of 01 to play the default scheme.  If you want to play the other pre-installed sound scheme, simply program CV60 to a value of 00.  You can switch back and forth between the two schemes.  Changing CV60 does not erase either pre-installed schemes.If you want to download ...

KB1033 Verifying BDL168 Board ID is set correctly

Q.  How can one verify that a BDL168 board ID has been set?     A.  If you have a DT40x Series throttle:  Press PWR, then DISP, and the  2 center "Mode" letters will show "In" for 'Input following report display'.Now any  <B2> or DS occupancy report/input messages will show in the middle 5x7 display line as:  Input number with H or L for state (high/low).Pressing any key or moving encoder will cancel this debug usage,  and mode goes back to "Fn".  

KB483 Bushby Bit - Disable Normal Switch Commands

Q: What's a "Bushby bit"? A: In your command station, OpSw27 can be toggled to disable normal switch commands, a.k.a. the "Bushby bit." This allows the layout operator to use an attached PC to handle switch control logic. Under normal conditions, advanced throttles can be used to operate turnouts which are controlled by LocoNet-connected stationary decoders. The factory default setting for OpSw27 is "t". Toggling OpSw27 to "c" takes this control away from the individual throttles and gives it to a controlling computer. Such an application would be a railroad with CTC control, where the train movements are directed by ...

KB676 Mobile Decoder Programming Overview

Programming is the process of setting the configuration variables (CVs) in your decoder to the appropriate values that will make the locomotive perform the way you want it to.  The first CVs that most people change are those that set the locomotive decoder's address.  The mobile decoder in your locomotive usually comes pre-porgrammed to a factory default address of "03".  Once you add a second locomotive, you will want to change the this new locomotive to another address.  Not doing so will result in both locomotives operating at the same time when you send commands to address 03.Likewise, there are a ...

KB498 BD1 - Connecting To Stationary Decoders

Connecting BD1 to a DS54, DS64 and SE8c? The BD1, block occupancy detector (replaced in 2004 by the BD4) was designed as an add-on device, which took advantage of the block occupancy message generating (over the LocoNet) capabilities of the DS54. The BD1 is also compatible, for the same purpose, with the DS64 and SE8c. The following diagrams indicated how to connect the BD1 to the rails, rail power source, and the Digitrax DS54, DS64 and SE8c.  Note: The wires that connect the BD1 to the rails and rail power source are characterized as two heavy, uninsulated, and polarity neutral wires.

KB840 Zephyr - Functions F0-F8

DCS50 Zephyr can control Functions F0 - F8. Most DCC mobile decoders have function outputs that you can use to control lamps, LEDs, sound, smoke generators and other on/off devices installed in your locomotives. Most locomotives made today come with a head light and sometimes with a rear light, too. With DCC, these are controlled by the decoder’s function outputs. You can also install additional DCC controlled lighting such as cab lights, Mars lights, ditch lights, rotating beacons and others on your locos. The addition of these functions can add to the fun and realism of your locomotives.You must have ...

KB370 LED Lights in Locomotives

I have this N-scale Proto A/B unit. I went to install the decoder in the A unit to the headlight, its an LED. My question is that once it was wired up and place on the track, I hit my headlight function and the light lit up then burnt out. This is my first wired decoder I ever installed with a head light. Can you tell me how to properly wire the led headlight to the DZ123 decoder so the light doesn't burn out? In looking at the DZ123 Decoder sheet, it suggests that I check the Decoder Manual for ...

KB190 Case Study: PUTRA Kelana Jaya Rail Line - The Railroad (Part 2 of 5)

The track plan of the model Kelana Jaya Rail Line is shown below: Included in the model is the double track mainline with crossovers, two elevated stations with center platforms, one at-grade station with outside platforms and two underground stations, also with center platforms. The storage yard, maintenance yard and reversing loop at one end of the system and the four track stub terminal at the other end of the system are also modeled. The yard, station tracks, crossing loops and distances between stations are all scaled to hold trains no larger than three cars. The layout is designed to ...

KB715 Customizing SoundFX Decoders

Digitrax SoundFX lets you make your locos sound like the real thing!Remember, your Digitrax SoundFX decoder is ready to run and will operate and generate sound using address 03 with no additional programming.On your Digitrax system, simply select the locomotive's address and the sound will start. On some DCC systems, it is necessary to select the locomotive address AND send a command to start the sounds. When used in conjunction with a separate DCC motor decoder in a single locomotive it is most practical to program both decoders to the same address and operating modes.For a more prototypical railroading experience, ...

KB342 Powering your Digitrax Railroad - An Example

  I have a 14x24 foot room with a shelf layout on two levels. 1st level is about 24 inches with two main lines and some industries, a moderate freight yard, moderate intermodal facility and passenger station. The second level is 18 inches and will contain one and two main lines with mostly industries. This would qualify as a "medium to large" model railroad. I would like to have 1-5 operators with 2-10 trains running at one time as permitting. At least four Universal Panels would give all operators full access to LocoNet as necessary. At least one UP each ...

KB825 Making LocoNet Cables

LocoNet typically supports a total cable length of up to 2,000 feet with no two devices connected by more than 600 feet of cable. LocoNet wiring is totally free-form. We do not recommend looping LocoNet back on itself.Making your own LocoNet Cables is simple and cost effective. LocoNet wiring consists of readily available wire and connectors. LocoNet uses flat 6 conductor wire and 6-pin RJ12 connectors. This kind of wiring is typically used for telephone wiring. Most Digitrax dealers can make up LocoNet cables for you. If you plan on wiring a large layout, you may want to invest in ...

KB1007 PS2012 - Overview and Installation

Regulated power supply delivers more power with less heat for more efficient booster operation. Operates up to 4 Five amp boosters. Scale selectable for use with N, HO or large scale. DC Ammeter. On/Off Switch. Integral cooling fan. Design coordinated for use with Digitrax products. One "Y" Cable (P/N YC52) Included for convenience with dual 5 amp protected outputs All secondary devices must be properly fused on their power input leads for their rated capacity. For example if you intend to use the PS2012 to drive a 5 and an 8 amp booster, you must input fuse these devices for ...

KB19 Case Study: Texas & Southwestern Part 4 of 11 - Track Plan

In response to a request, here is a semi-official track plan of the Texas & Southwestern: The railroad uses Kato Unitrack: 249mm radius curves 282mm radius curves Seven #4 Right turnouts, configured to be "non current routing" Five #4 Left turnouts, configured to be "non current routing" Two 90° crossings A variety of straight tracks, including the 20-091 Short Track Assortment Three 20-050 Adjustment Tracks Several 24-818 Terminal joiners to supply power to the railroad and to connect the AR1 to the reversing segment Insulated Unijoiners were used to define the reversing segment. Alert readers will note that the tracks ...

KB230 BDL168 - Power Districts and Transponding

Is it possible to add a pair of PM42 Power Management Modules between the command station Rail A/Rail B outputs and run the resulting output from the PM42's on as many as 8 sets of Rail A/Rail B Wires to 8 isolated power Zones? These isolated power zones could have their Common Zone (Rail A) Wires running through RX1 transponding receivers connected to an RX4 ribbon cable running to the BDL168 for the purpose of interfacing with the SurroundTraxx Multi-Train Sound System. If this is possible, it would only require 5-6 of the DS lines on the BDL168 to be ...

KB484 DS64 or SE8C for Slow Motion Turnout Machine Control?

Q:  We will be using your SE8C's for signaling. Should we use the SE8C to control our slow motion switch machines, or should we use your DS64s for that function? A:  Both products will do the job. How you plan to use them on your layout will help you decide which is better in your situation. Here are some things to consider in making your decision:The SE8C will drive 8 slow-motion switch machines while the DS64 will drive four. If you have a large number of switch machines in a specific area, the SE8C might be a better choice, since the ...

KB975 PM42 - adjusting the PM42's current settings?

Use a throttle to change the PM42's Option Switches 01, 02 and 09 as detailed in the PM42 instruction manual. The PM42's trip current threshold can be set at a value from 1.5amps to 12 amps. Always use the lowest possible setting, consistent with good operation and reliable short circuit detection and recovery. Higher current settings are not "better." We ship the PM42 with a moderate current trip threshold of 3amps so it will work on most DCC boosters and layouts with no changes.This is because some boosters cannot supply enough current with the track feeder resistance to reliably allow ...

KB991 Case Study: Texas & Southwestern Part 1 of 11-Table of Articles

Case Study - Texas & Southwestern The Texas & Southwestern is a small N-Scale model railroad that features a Zephyr. Here are a variety of short articles which detail the various facets of the construction and operation of this railroad. Background-Part 2 The idea behind the railroad. The Railroad-Part 3 Planning the railroad Track Plan- Part 4 Powering the Railroad-Part 5 Zephyr makes things easy. Wiring the Railroad-Part 6 Hooking things up for reliable operation. Reverse Loop-Part 7 AR1 makes things easy, but a little change in thinking is sometimes necessary. Programming Track- Part 8 A convenient feature. Zephyr Heat Problem- ...

KB1045 Updating and Using DT402R R2 and DT402 IR R2 throttles with your DCS240.

Updating and Using DT402R R2 and DT402 IR R2 throttles with your DCS240. Access to expanded slots in the DCS240 are only available to Tethered DT402 throttles with IR and Radio(RF1) throttle options set to off and DT402D throttles.  By default these options are set to OFF in the DT402 R2. DT402R throttles can access expanded slots in the DCS240 if IR and Radio(RF1) throttle options are set to off.  The DT402R will still operate in simplex radio mode with the DCS240 however it will only have access to standard slots. Practically, this means that you have two options for ...

KB679 Adding Radio and IR to a Big Boy Starter Set

Can I add Radio and IR to my Big Boy?Yes.Adding radio and/or IR to Big Boy is the same as adding it to any other existing Digitrax layout or Digitrax Starter Set. Digitrax offers InfraRed, Duplex Radio and Simplex Radio systems for wireless operation. Any combination of these wireless methods can be used on the same layout at the same time.Infra Red Wireless OperationAll current Digitrax throttles are Infrared capable (InfraReady) in that they come from the factory equipped with the IR emitters required to send IR information to LocoNet. To use this functionality, you only need to add one ...

KB2 LocoNet - DigiMon ReadMe

This program allows monitoring of LocoNet message traffic and operations. It is available on our downloads page as a ZIP file and is provided for Digitrax customer convenience. This utility is provided on an as-is basis for users with Windows based machines configured to work with this software, and the ability to perform the setup and operation tasks detailed below. Techsupport is not configured to diagnose issues related to operating system, hardware, configuration or other possible problem areas that may cause problems with running these utilities.   This program allows monitoring of LocoNet message traffic and operations. a) Copy this ...

KB1044 DT402 R2 Release Notes

DT402 R2 Release Notes Access to Expanded Slots Updating the DT402 to R2 gives the throttle access to expanded slots in the DCS240 Advanced Command Station.  Access to these expanded slots are only available when IR and Radio(RF1) options are set to OFF in your throttle.  This means that throttles working in IR mode or Simplex Radio will not have access to the expanded slots.  Simplex Radio throttles(DT402R) will have access expanded slots if radio(RF1) is set to off and the throttle is plugged in.  It is recommended that throttles be factory reset after upgrading the firmware to R2.  By ...

KB319 DCS100 - CONFIG Indicator

The green CONFIG Indicator shows the primary operating mode of the DCS100. This indicator should be steady green blinking off briefly once every 4 seconds. This indicates that the setting for DCS100 Option Switch 05 is set up correctly. If you see 8 blinks every 4 seconds then we recommend that you change the DCS100 Option Switch 05 to closed. The DCS100 will operate correctly in either case. The CONFIG Indicator will be mainly off when DCS100 option switch 01 is incorrectly set to closed. In this case you must change option switch 01 to thrown for correct operation.

KB502 PR2 - Red and Green LEDs

  Q:  On my PR2, I have been getting the red light and message saying COM Port Paused a lot when trying to read CV’s. A:  This operation is normal. Whenever you bring up any of the auxiliary menus such as Soundtest or CV editing, the main Soundloader screen pauses its communication with the PR2 so the auxiliary menu operation can take place. When in the normal main screen, the program is constantly talking to the PR2 so it must be paused to allow these other activities to take place. Unless you are not able to read/write CV's, this should ...

KB668 DT300 Control Panel

The DT300 Throttle is a full-function hand held controller that includes 2 independent throttles and a common keypad to control up to 9 functions (0-8), turnouts and programming. The DT300 Throttle does not require a battery in normal walk-around operation, but if you do not install a battery, the throttle display will be off while you are unplugged from the system. The DT300 requires a 9 Volt battery for infrared operation.   The DT300R requires a 9 Volt battery for radio operation.

KB803 DS64- Output Type Static or Pulse-Option Switch 01

Determines The Type of Turnouts You Can OperateOpSw 01 defines the output type (static or pulse) for the decoder. Thrown (factory default) for pulse output mode to operate three wire (twin coil type) PecoTM or Atlas Snap SwitchesTM or two wire bi-polar type turnout machines such as Kato Unitrack, AristoCraft, or LGB.Closed for static output mode to operate slow motion (stall motor) type turnouts such as Tortoise or Switchmaster.

KB708 UT4 - Controlling Functions (Lighting, Couplers, Sounds, etc.)

UT4 Function Control Keys and How they WorkThere are 8 physical keys used to control functions F0-F12 on the UT4 throttle. F1 through F6 and F7-F12 share the same keys.  You will see F1-F6 in black print and F7-F12 in blue print to remind you that you will need to use the SHIFT key to access F7-F12. To use functions F7-F12 you must press and hold down the SHIFT key on the lower left row of the throttle as you press the F7 through F12 keys to activate any functions available on those functions. All the UT4 functions work like other Digitrax throttles. ...

KB807 DS64 - Slow-motion turnout machines & crossing gates

Hook up for slow motion type turnout machines & crossing gates.Note: Multiple turnout machines of the same type can be operated on a single DS64 output.For example, you can run 2 Tortoise or Switchmaster machines on a single DS64 output.Note: If you find that your turnout is operating “backwards” simply switch the + & - wire connections to achieve correct operation.Note:  The outputs can be configured to drive a grade crossing signal.  See Knowledge Base article.

KB273 DS64 - Fulgurex Switch Motors

For some reason it is not possible to successfully operate Fulgurex point motors with a DS64. Tortoise work fine. We have determined that the Fulgurex motor draws too much current for the DS64. Published sources describe the Fulgurex motor as needing 400 Ma for operation, which is well beyond the capacity of the DS64. When the DS64 tries to operate Fulgurex motor, the excess current draw appears to be a short circuit and the DS64 shuts down to protect itself. The Tortoise, while also a slow motion point motor, is "on" all the time since it is a stall-type motor. ...

KB733 DT402 & DT400 Series Throttles - Emergency Stop - Local

DT402 & DT400 series throttles have two ways of doing an emergency stop. When you use Emergency Stop, the deceleration rate programmed into the decoder will not have an effect and the stop will be immediate.Local Stop Press the EMRG STOP Key to stop the loco that is active in the throttle display. To resume operation, use the throttle knob associated with that address to increase the loco’s speed.Press the EMRG STOP Key again to stop the loco that is associated with the other throttle on the DT400 or DT402 series throttle. To resume operation, each operator must use their throttle to set ...

KB243 UT4 Throttles Overview

The UT4 series, UT4, UT4D & UT4R are "traditional" style throttles.  The UT4s were developed from a specification submitted by Digitras users through the Digitrax Yahoo group. These throttles were designed by operators for operators.  They are also great for beginners because of their intuitive controls and reduced feature set. By not offering all the bells and whistles, beginners can run your railroad without accidentally changing settings that might cause problems.   Works with any LocoNet compatible system   4-Digit addressing   Functions F0 - F12 for lighting and sound decoder operation   Direction switch with center brake position   ...

KB24 DT402 & DT402R - Safety Selection of Locomotive Address

Selecting a locomotive-Safety Selection While unplugged, the DT402 (IR only) and DT402R (IR and Simplex Radio) operate as one-way transmitters. The DT402 and DT402R must be plugged into LocoNet to select an available locomotive address. After an address is selected, you can unplug from LocoNet and run the selected addresses with infrared or simplex radio. The throttle will automatically convert to infrared or simplex radio operation for all speed, direction, function, operations mode programming, and switch commands. The DT402D throttle has full duplex radio capabilities. Once the 402D has been configured to communicate with a UR92, the full functionality of ...

KB473 Dividing the layout up into blocks

Q:  I am the only operator. There will be no others. I wish to use block detection for signaling. However, I find that I cannot use the BD4s in the way I thought they could be used. My question, must I divide my simple layout into blocks (which DCC says you don't really need) in order to use the BD4's and SE8C together? A small basic layout can be operated in the DCC environment without dividing the railroad up into power districts.  In this scenario, you will use one command station/booster to power the entire layout. As your power consumption ...

KB234 CV29 - Speed Tables

  CV29 is assigned a single value which chooses a combination of specific effects: 1. Speed step control. 2. Speed table On or Off. 3. Analog mode conversion On or Off. 4. Normal Direction of Travel (NDOT). 5. 2 digit addressing or 4 digit addressing. Speed Tables: Speed tables can be enabled or disabled with CV29. Speed tables are used to customize the throttle response curve of each decoder equipped locomotive. The speed table values can be stored in the decoder and then the table can be turned on or off with CV29. One example of such usage would be ...

KB605 DS52 Stationary Decoder Configuration and Programming Jumpers

There are two jumpers on the DS52 stationary decoder board. To properly use your DS52 you must be sure these jumpers are in the correct position. The configuration jumper sets whether your DS52 operates slow motion or solenoid type turnout machines. When the jumper is open it will run solenoid turnout machines. When it is closed it will operate slow motion turnout machines. The programming jumper determines whether the DS52 is in programming mode or not. To program the addresses for the DS52 the program jumper must be closed. For normal operation, it must be open. 

KB800 DS64 - Using A Virtual Top Address for Routes

When you program the DS64, you must program all four outputs, even if they are not connected to anything.  A "Virtual" top address can be used to avoid conflicts with actual turnout addresses and other routes. To create a virtual top address use a switch address for your top address that is not used to operate an actual turnout on the layout. The advantage of this is that you can consistently use either the "thrown" or “closed” command to operate all routes, making it easier to remember which position goes with which route to make them work. Since DS64 routes ...

KB454 DT402 & DT400 Battery Installation

For normal tethered operation, DT402/DT400 throttles do not need a battery. If you want to use your DT402/DT400 as an infrared or radio throttle (R & D version), you must install a 9 volt battery.  You can use rechargeable batteries.DO NOT USE ANY OTHER TYPE OF BATTERY-AA BATTERIES DO NOT WORK. When you install the battery, the throttle will report the battery voltage and then display Idle. Once you plug in to LocoNet, the throttles will begin operating infrared and Ds and Rs will begin operating as duplex and simplex radio throttles. We recommend that you remove the battery from throttle if it is unplugged ...

KB165 Recommended Tools for Decoder Installation

You'll need a few simple tools when you begin installing decoders: A soldering iron, preferably temperature controlled. Though many installations do not require soldering, you may still need to use a soldering iron to install extras like lamps for special lighting effects. Solder. A small screwdriver for disassembling your loco. Small diagonal cutters for cutting & stripping small wire. Tweezers to pick up small loco parts. Heat shrink tubing for protecting wire connections, this is better than electrical tape. 1. Read the instructions FIRST and PLAN your installation. Have the proper tools on hand. 2. Choose a locomotive that runs ...

KB153 DZ125 - Installation Notes

Installation Notes: 1. Do not exceed the decoder’s 500mA total function output rating. 2. We recommend that the Blue wire, also called +Common or Lamp Common, be connected as shown. If you wish to omit the Blue wire in your installation, consult the Digitrax Decoder Manual for more information. 3. The head lamp should be hooked up using the Blue/+Common wire for optimal Digitrax transponding operation. 4. To use a function output with an inductive (coil) type load, see the Digitrax Decoder Manual for more information to avoid damage to the decoder. 5. See the Digitrax Decoder Manual for full ...

KB43 DS51K1 - Special Notes on Kato Double Crossover 20210

Kato makes a Unitrack double-crossover, their No. 20210: Kato has advised us that this unit has four solenoids in its base, each operating one turnout point set. Connecting the DS51K1 to the red / black wire pair at the base of the track will damage the decoder since the four solenoids of the crossover will draw more than the rated current capacity of the DS51K1. If you are wiring the DS51K1 internally to this track segment, it is easiest to program each turnout pair to the same address; done this way, activating one track switch address will result in the ...

KB351 Broadway Limited - Blueline Locomotives

Overview: Broadway Limited has issued a new line of H0-Scale locomotives called "Blueline". These locomotives are equipped with sound decoders that can be operated in a conventional Direct Current environment. They also are fitted with an 8-pin DCC Medium plug to allow for conversion to a DCC operating environment. Among other decoders, Broadway Limited recommends using our DN143IP mobile decoder for this purpose. Converting these locomotives is simple, but programming a 4 digit address can be a challenge. BLI has a support page which indicates that changing the locomotive address and other CV's can be done in OPS Mode (also ...

KB276 DS64 - Push Buttons

In addition to controlling turnouts via LocoNet with your DT400 throttle or with a computer program such as Railroad & Co., you can use local push buttons to operate turnouts. These buttons can be mounted near a particular turnout on the layout fascia or on a local track diagram. In this way, train crews can operate a turnout with a push of the button. The momentary push buttons are connected to the DS64 inputs marked S1, S2, S3 and S4. The return connection of each push button is made to "+COM. Here, a momentary button is connected to operate Turnout ...

KB828 Zephyr - Switch Mode

Switch Mode is used for sending commands to accessory decoders and for changing Option Switches (OpSw) in your DCS50. The most common use of switch mode is for operating turnouts (track switches).To change the position of a turnout:This note assumes that you have already installed and programmed turnouts and turnout decoders on your layout.  Each turnout is connected to a stationary decoder that controls the operation of that turnout.  There are several different stationary decoders for this purpose such as DS64 and others.  Please see the related articles below.1. Press the SWITCH Key. 2. The last switch address selected by ...

KB100 DB150 - Track Power On and Off with a DT400 series throttle

How To Turn Track Power On and Off with the DT400 series throttle Turn track power on: Press the PWR Key, then press the Y + Key and the Track Power Indicator on your DT400 series display and on your command station will come on solid. If the track power indicator is blinking, press the Y+ key again to make it solid. Turn track power off: Press the PWR Key , then press the N - Key . The Track Power Indicator on your DT400 series and on your command station will go off. To Exit: Exit PWR mode by pressing the ...

KB687 What Can Transponding do?

Transponding gives you operations mode readback of decoder CVs while they are on the layout (for decoders with this feature). Your dispatcher will know where trains and other equipment are located. Feedback from your transponding decoders lets you know the zone location and address of any piece of transponding rolling stock on the layout. This information can be presented on a display panel, your computer or even on your throttle. Feedback from the locomotive decoder also can provide information about the speed and other status data for the specific locomotive. With transponding, you can FIND the location of a specific ...

KB997 Adding another WTL12 to your layout as a second Booster/Throttle

Since each system, no matter how large, needs only one command station, you need only one WTL12 (or other Digitrax Command Station) performing this function. Any additional WTL12s must be converted to a booster by following the startup directions described below: Disconnect the power from the WTL12 unit Press and Hold the VOL- key Reconnect the power while continuing to hold the VOL- key Release the VOL- key The WTL12 is now configured as a booster/throttle only.  The power button will be lit up red on the right side. The command station determines the total number of locomotive addresses your ...

KB467 Athearn DD40 HO Decoder Install with Two Motors

Q: I have a late 70's or early 80's Athearn EMD DD40. An article on Wiring For DCC suggested a DH83FX - 2amp decoder for Athearn "Covered Wagons." The pictures look like the inside of my loco except the DD40 has twin motors with joined drive shafts. In researching your site, I realize that the DH83FX is no longer manufactured, but I was led to the DH163AT as the current replacement. Will this work? I have some other Athearn SD40 units, same vintage, but single motors. Is this the correct decoder for them? A: The "AT" in the decoder name ...

KB942 CV61 - Non-directional Headlights, Transponding, & Split Phase Motor Drive

Characteristics Controlled by CV61:Some Digitrax Decoders use CV61 (one of the manufacturer specific configuration variables) to give you the following options:  Non-Directional Headlight Operation, Transponding Enabled or Disabled, & Split Phase Motor Drive for Märklin AC and Lionel Type motors.The look up table below shows the effects of different CV values that you can program into CV61.  CV values are shown in hex & decimal are the same in this case.TABLE 61: CV61 Values CV 61 Value Non-directional headlights Transponding Split Field Motor/AC 00 No No No 01 Yes No No 02 No Yes No 03 Yes Yes No 04 ...

KB23 UR92 - Configuring the Duplex Group Password (key)

Configuring the Duplex Group Password The UR92 ships from the factory with the default Duplex Group Password of 0000, the value that disables password requirements. You may have an occasion when operating in a multisystem environment when you may want to restrict access to your layout and operating system via a tetherless Duplex Throttle. The password for your Duplex Group may be activated or changed: 1. Plug a DT402D or DT500D throttle into the UR92. 2. Press the EXIT key. 3. Press the OPTN key then the EDIT key. 4. Enter a 4-digit number using the numbers on the keypad ...

KB612 CV13 Analog Functions

Digitrax decoders allow for operation on both Digital Command Control (DCC) powered and on traditional Direct Current (DC) powered model railroads.  Decoders from other manufacturers may or may not have this featureModern Digitrax Decoders are shipped with analog functions enabled to allow you to have working functions on locos on either type of layout without changing any CV values.  (Series 3 decoders and later) When a Digitrax Series decoder with analog functions enabled moves from a DCC track section to an analog track section, the functions that were active on DCC will remain active on DC.  For these decoders, CV13 is ...

KB195 PR3 - Hardware Setup

SoundLoader and PR3 have been tested to work on PC compatible computers running at 550MHz and up with Windows XP or Vista, 512MB of RAM. Other combinations of hardware and software such as Windows 98 may also work, but are not supported by Digitrax, and have not been tested to operate properly. Installation consists of three steps: Hardware installation, software installation, and software setup. Below is a photograph of the actual hardware connections required for SoundFX programming. Assemble the PR3 hardware as shown in the diagram below and connect to an appropriate power supply (Digitrax PS14 or equivalent). Note the ...

KB680 Can I add Radio and IR to my Zephyr Xtra?

  Can I add Radio and IR to my Zephyr Xtra?Yes.Adding radio and/or IR to Zephyr and Zephyr Xtra is the same as adding it to any other existing Digitrax layout or Digitrax Starter Set. Digitrax offers InfraRed, Duplex Radio and Simplex Radio systems for wireless operation.  Any combination of these wireless methods can be used on the same layout at the same time.Infra Red Wireless OperationAll current Digitrax throttles are Infrared capable (InfraReady) in that they come from the factory equipped with the IR emitters required to send IR information to LocoNet.  To use this functionality, you only need to ...

KB546 UR90 Infrared Receiver Getting Better Reception

Q:  Where do I locate UR90 for best performance? A:  Infrared signals are transmitted and received in the line of sight between the transmitter and the receiver.  Most problems with IR reception are caused by people or things blocking this line of sight.  UR90 should not be mounted in the layout fascia below track level because that is where we stand when we run trains.UR90 works best when mounted on a wall, opposite the operators, near the ceiling, at a 30° to 45° downward angle. The reason for this positioning is simple. When you are making speed and function changes on ...

KB598 Z-Scale decoder installation?

I have an extensive collection of Z-scale locomotives (some are older (15-20 years) Z-Scale Maerklin equipment).  Can I convert the locos to Digitrax, or must I buy some other brand of loco to use Digitrax?Maybe yes, maybe no.  It depends upon the size of the locomotive and how much space is inside.There are several Z-Scale layouts that use Digitrax decoders.  Z scale railroaders are very persistent and precise so, they are often able to install decoders where members of other scales would fear to tread.  Digitrax continues to design smaller and smaller decoders aimed at the Z scale market.  Z Scale ...

KB209 Amps To Run Your Railroad

Fortunately, most DCC railroad wiring is very simple and easy to install. One critical point for any DCC system is power consumption, how much power an individual Booster is able to deliver. The available power is measured in terms of Amperes or Amps. The higher the Amp rating, the more power is available to run your layout.Amps have often been compared to water pressure in a pipe. When the pressure is low, turning on one faucet will draw from that water pressure. As more faucets are opened, the water flow from each faucet drops. One solution is to turn off ...

KB251 DH165Q1 - Installation Instructions

The DH165Q1 fits many Atlas, Intermountain, Life-Like & Other factory sound equipped HO locomotives. Installation Instructions - Intermountain F7 example: Removing Locomotive Shell and Disconnecting Lightboard 1. Carefully remove the front coupler and then the locomotive's shell from the frame. Note the orientation for proper reinstallation. 2. Unplug and mark the two track power pickup 2-pin plugs, the motor 2-pin plug and the 6-pin headlight plug(Figure 1) Observe and carefully note the original wire locations! One of the track power plugs and the 2 pin motor plug can be inadvertently swapped when hooking up the new decoder PCB. 3. Unscrew ...

KB654 DT300 - Slot Following

When the command station is sending commands to a loco address that is in-use on one of the DT300's throttles and that address is being changed by another throttle or computer, it will cause the DT300 to “click” every time it sees a remote throttle change its locomotive settings. If that locomotive is in the active throttle, its speed display will also show the changes. This is called slot following. This allows two DT throttles to run a single locomotive address with both throttles being able to send commands to the loco. Both throttles will show the current speed and direction of ...

KB122 Atlas H0 Turntable

  I have an "old" vintage mid 1970's Atlas Turntable and I need to know how to wire the bridge track using DCC. Does it need an autoreversing unit or not?No. The Atlas H0 turntable is an evergreen for the model railroad hobby. It was easy to install and simple to wire, making it quite popular.Power is fed to the turntable bridge by connecting the track power feeds (black and red) individually to two screw terminals; these terminals are built into the portion of the Atlas turntable base which also includes the turntable manual crank handle. The turntable itself is ...

KB882 Installation of Digitrax Wired Decoders in Bachman Plus HO ABA F7s

This note addresses the installation of an H0-Scale wired decoder into Bachmann Plus ABA F-7s; it calls for using a DH140, which has been retired.  Current decoders such as the DH123 or DH163 or similar wired decoders can be used. Just finished up doing a few HO Bachmann Plus F7's, ABA's to be exact. Thought maybe some of you might be interested in how the DCC conversion went on these.They are an easy conversion!1.  The full stall current for these ranged from 500-700 ma for each loco . I selected Digitrax DH140 for the A units and a DH120 for the B ...

KB780 DT400 Features and Specifications

DT400 is designed to maintain a close similarity in function & feel with Digitrax DT300, DT200, & DT100 series throttles. This family resemblance makes it easy to add new throttles to your Digitrax Command Control System and be able to use them in ways similar to the existing throttles that you are already used to. DT400 can be used with any Digitrax LocoNet System or other LocoNet compatible DCC system.   User friendly Multi-line Backlit LCD with easy to read icons and messages.   Prompts in the display guide you every step of the way. To make operation easy and ...

KB30 DT402 - Display Basics

1. The DT402 handheld has two knobs called the L Throttle (Left) and the R Throttle (Right). The throttles are used for speed control, direction changes, and input of information for operation of your railroad. 2. The row of numbers (0-9) across the top of the display are the functions being used by the active locomotive throttle. 3. The larger numbers in the middle of the screen indicate the speed of the locomotives being controlled by the throttles. 4. The numbers at the bottom of the display are the locomotive addresses, and correspond to the digital decoder that is in ...

KB638 PR1-Setting Up Ditch Lights

The following CV set up simulates prototypical ditch lights that are on steady when running and alternately flashing when the horn blows. The ditch lights will be on when the engine is running, when you simulate blowing the horn by going into function mode and pressing F2 the ditch lights will flash on alternate sides of the loco. Note, the F2 key on Digitrax throttles is set up as a non-latching function so that the function assigned to F2 will be "ON" as long as you hold the F2 key down and will go "OFF" when it is released. Follow ...

KB1040 When I turn on the system, the DCS240 beeps 10 times and track power goes off.

When I turn on the DCS240 and system, the DCS240 beeps 10 times and track power goes off. When I retry turning on track power, the 10 beeps occur again and the track power stays off. What is happening, and how do I fix this so I can run trains? The DCS240 actively scans for conflicting Command Stations at Power up, any time Track power is turned ON, and additionally about every 2 minutes.  If another Command Station is detected the DCS240 will issue 10 long beeps and the Track Power is turned off.  The DCS240 will not allow track ...

KB508 DS54 - CML DTM30 Super Tower Panel

Q: I am setting up a yard control panel with a CML Electronics DTM30. For the DTM30 to know what state a turnout is in, it can issue an interrogate command but my DS54's do not seem to respond with this information. Is there a trick to this? A:  According to CML: The DTM30 makes use of the “Interrogate” feature that all modern Digitrax systems use. After power up, the Command station normally sends out 8 switch commands. All accessory devices respond to these, and send LocoNet messages back reporting sensor states and point states. The DTM30 can also send ...

KB171 PR3 - Stand Alone LocoNet Interface Applications

Under what conditions can the PR3 be used as a Stand Alone LocoNet Terminator? The PR3 is so designed so that it can be configured to act as a stand alone LocoNet controller in the event that a Digitrax command station is unavailable for the control of a series of LocoNet compatible devices. There are two major situations that would require the PR3 to act as a stand alone LocoNet controller. The first situation is where one of the many advanced features offered by the LocoNet and the various LocoNet compatible devices is desired to be used on a layout ...

KB1072 Extra DS78V servo setup information

The Series7 Stationary (or Accessory) decoders are configured to not use, or need a CV Service Mode (SM) programming track. It is impractical to disconnect these fixed wired devices from a layout to configure on a SM track, unlike a mobile locomotive decoder. Series7 devices are configured when operating on a working LocoNet system to access all product capabilities. As detailed in the product Instruction Sheet (IS), the units have a number of Option Switches (OPSW's) that may be modified by; pressing the OPSW button and sending the appropriate SW# as Thrown or Closed. The IDSW button allows the setting ...

KB157 DZ125 - Installation Instructions

1. Carefully remove the locomotive’s shell from the frame. Notice the orientation of the shell to the frame so that you can reinstall correctly. 2. The DZ125 has 6” wires that you will solder directly to the appropriate connections inside the locomotive. The smaller size allows the decoder to be easily installed in a variety of locomotives. The bare ends of the wires are wired to the motor connections, power pickup connections and the lights according to this standard. Note: Avoid stressing the solder connections of the wires to the decoder board. If a connection is broken, carefully solder the wire ...

KB197 The Layout - Some thoughts on troubleshooting

  The most common problems on the layout that will impact your DCC system are electrical short circuits. If you find that you cannot get the Track Status light on your command station to come up, or there are numerous beeps from the booster, then disconnect one of the Rails from the booster and the problem should be apparent. There is an electrical short in your layout wiring. The quarter test is the BEST diagnostic tool that you have! With your DCC system up and the Track Status ON, create a short circuit across the rails of the layout every ...

KB175 Erratic loco speed

Loco is running fine, then suddenly slows down, stops for a few moments, then starts up again to its original speed. This happens repeatedly and randomly (not at the same locations). Wheels, track are clean, doesn't seem to be a problem with other locos. Running HO using the Zephyr with Digitrax decoders. You did the right thing to make sure that the track and wheels are clean; that is one of the most common sources of problems with model trains, DCC or otherwise. What is probably happening is that the locomotive has been selected by two throttles. You are operating ...

KB235 CV29 - Speed Steps

  CV29 is assigned a single value which chooses a combination of specific effects: 1. Speed step control. 2. Speed table On or Off. 3. Analog mode conversion On or Off. 4. Normal Direction of Travel (NDOT). 5. 2 digit addressing or 4 digit addressing. Speed Step Control. There are two modes for speed step control: Standard (14 speed step mode) and Advanced (28/128 speed step control). Because of differences in the capabilities of DCC compatible command stations and decoders, you may have to set CV29 in your decoders to different values to match the mode of the command station ...

KB501 Soundbug Q & A

Q:  What is the white wire for on the SoundBug? A:  The white wire is used on conjunction with a driver cam for steam sound synchronization. Q: What type/size loco does "generic" steam sound represent? A:  This sound was based on recordings of Union Pacific 3985, a 4-6-6-4 "Challenger" type.  Q:  Does the Sound bug come with an oval speaker to fit in the shell of the older model GPs or SDs that do not have space in the fuel tank. A:  The SoundBug comes with a 28mm round speaker but others may be substituted. The included-speaker is rated at ...

KB486 PM42 - Programming Op Switches with a DT400 series throttle

Q:  How do I program the PM42 Option Switches (OpSw) with a DT400 throttle? A:  The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSws is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the DT400 series throttle with any Digitrax command system. 1) Connect the PM42 to a DCS50, DCS51, DB150, DCS100, or DCS200 with a standard LocoNet cable. 2) Connect the PM42 to an external power source; Digitrax ...

KB487 PM42 - Programming Op Switches with a DT300 Throttle

  Q:  How do I program the PM42 Op Switches with a DT300 throttle? A:  The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSws is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the DT300 throttle with any Digitrax command system. 1) Connect the PM42 to a DB150, DSC050, DSC100 or DSC200 with a standard LocoNet cable. 2) Connect the PM42 to an external power source; Digitrax recommends the ...

KB557 CV29 - Configuration Register Look Up Table Method

CV29 is called the configuration register. It controls the following decoder characteristics: 1.  Whether the decoder uses 14 speed steps, 28/128 speed steps or loadable speed tables.  This affects how smoothly the loco will move and how it responds to throttle controls.2.  Whether the decoder automatically converts to analog mode when no DCC signal is present.  This allows the decoder to operate on a DC layout even though it is DCC equipped.3.  Defines the normal direction of travel for the locomotive. Normal Direction of Travel or NDOT can be changed when the motor connections of decoder have not been connected so that the locomotive runs ...

KB388 DZ121 for the N-Scale Life-Like SW1200

Prior to Disassembly Test the Decoder All Digitrax decoders are tested for proper operation before they leave the factory, but sometimes strange things happen. Therefore to insure your decoder is covered under our warranty policy, please give it a thorough test BEFORE you cut the wires. Test Run the Locomotive Be sure it runs correctly in both directions with no unusual noises or binding in the motor-gear train. If it checks out OK, then: Get Ready Before you start, get your tools and supplies together for this project. You will need the following items: DECODER TESTER - Such as the ...

KB865 DB200+ - 8amp Booster Instructions

The DB200+ is the 8 amp booster. It has NO command station capability. This booster was designed for adding power to layouts that run lots of locos and for large-scale layouts where power requirements are heavy.DB200+ Control PanelNOTE: DB200+ front panel graphics may vary from those shown here.  Internally the booster is the same. These instructions are written for both versions of graphics as well as the DB200+ OPTO optoisolated version of the booster. About the Green Jumper WireEvery DB200+ is shipped with a green jumper wire on the front panel Booster Terminal Plug connecting Synch & Ground or ‘Config ...

KB940 Decimal and Hexadecimal Numbers

Over the years, different Digitrax throttles have used a combination of decimal, modified hexadecimal and hexadecimal numbers for entering CV numbers and CV values.  The following information is provided as a programming reference to show you how these different schemes work so that you will be able to use your throttle to program decoders.UT1 & UT2 Utility Throttles use decimal numbers exclusively for CV numbers and CV values.  Because these throttles use 2 selector switches that can access the numbers 0-9, you are limited to programming only CV#s and values from 00 to 99.DT100 Throttles use a modified hex numbering ...

KB278 Marklin Z-Scale

I have an extensive collection of older (15-20 years) Z-Scale Maerklin equipment. Can I convert the locos to Digitrax, or must I buy some other brand of loco to use Digitrax? Maybe yes, maybe no. It depends upon the size of the locomotive. We are aware of several European Z-Scale model railroads that use Digitrax. We also know of a very large Z-Scale railroad in Washington, DC that uses Digitrax. This particular railroad is a model of Swiss prototype, so the locomotives are all electric-types; there seems to be enough room inside for a decoder, especially the new DZ125 series ...

KB158 UR91 Discussion

Here at the Tech Support Depot, it has been our goal to improve operators' understanding of the Digitrax system of model railroad command control. We often see thoughtful words from others who are not employed by Digitrax that still have an in-depth understanding of the product line. Here, Doug Stuard talks about the UR91; these words originally appeared on the Yahoo Groups Digitrax discussion list, and are used here with his kind permission. UR91 and Throttle Antenna The UR91 antenna is the pair of 3" wires that sprout from the PC board that are arranged in a "V" similar to ...

KB488 PM42 - Programming Op Switches with a Zephyr (DCS50 or DCS51)

  How do I program the PM42 Op Switches with a DCS50 (Zephyr) throttle? The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSw's is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the keypad of a Digitrax Zephyr. 1. Connect the PM42 to the Digitrax Zephyr with a standard LocoNet cable. 2. Connect the PM42 to an external power source; Digitrax recommends the PS14. Note: Before entering Switch Mode ...

KB394 DS64 - Cascaded Routes Example

A cascaded route is where the last command of a route triggers the next route; this is also known to some as a nesting route. With the capacity of 8 turnouts per route, it becomes necessary to cascade routes if more than 8 turnouts are involved in a route. To highlight these possibilities, we use a very complex scenario with many turnouts and possible routes. Cascading routes allows the setup of long routes without the need for a computer. Since some routes exceed the capacity of 8 turnouts, the remaining turnouts of the long routes are setup in the second ...

KB140 PM42 - Programming Op Switches Without a Digitrax Throttle

Is it possible to configure the PM42 for auto reversing without a Digitrax throttle? We're accustomed to working in the Digitrax operating environment, so our answer is theoretical at best. However, it would seem that any operating software with a LocoNet interface could be used to set the PM42 address, using the software as a throttle in this situation.

KB279 Button Control of Kato Turnouts

I have my Kato Switches hooked up to a standard switch panel with toggle momentary switches. Can I hook up the DS51K1 stationary decoder in addition to this wiring? In other words, if hooked up the DS51K1 to the Kato Switch Machine that was already wired to another source to throw the switch, would the momentary power damage the decoder when it is operated by the standard control panel? I would like to operate these switches via DCC and by the control panel. In this situation, it would appear that using a DS64 configured for Kato turnouts (solenoid turnouts) and ...

KB287 CV54 Torque Compensation

CV54: Torque Compensation & Switching Speed In FX3 decoders, CV54 is used to control the decoder's torque compensation and switching speed features. Torque Compensation improves loco performance by internally adjusting for the loss of torque caused by SuperSonic™ operation. This feature is turned on at the factory. Switching speed gives you fast access to lower speeds used in switching operations. This feature effectively reduces the throttle's target speed by about 50% and reduces the effects of acceleration (CV03) and deceleration (CV04) programmed into the decoder by 1/4 when the user activates this mode by turning on F6.

KB292 Features of Series 3 Decoders

 Digitrax Series 3 Decoders include the following features and more: FX3 Function Outputs Supersonic motor drive for quiet operation Support for all DCC programming methods One-Step decoder factory CV reset Motor isolation protection White or Golden Yellow LEDs on decoders that come equipped with LEDs Operations mode read back capability for CV read back on the main line

KB344 PM42 - Programming

On Page 9 of the instructions (under 5.0 Op Sw Set Up) I am to connect my DT400 throttle to my powered PM42 . . . 1. Does “powered” mean having the PS-14 power supply to the PM42 connected and energized? Yes. We took another look at the documentation and it means that the PM42 should be operating with its own power supply. What you are doing is using the DT400 to program the internal controls of the PM42; to do so would require that the PM42 be in its operating state, thus the power supply. The DT400 is merely ...

KB525 DS54 - Two Button Turnout Application

Q:  Can I set up the DS54 for two-button operation turnout control? A:  Two-button control (one button for setting the points to the main route and the other button for setting the points to the diverging route) is a standard configuration for the control of any turnout.  The following charts indicate operating criteria and CV settings. 

KB717 Using SFX064D with other DCC Decoders

The sound project loaded into this decoder can be operated independently of any other DCC motor or function decoder. If another non-Sound FX compatible DCC decoder is connected to the track leads then CV readback of SFX064D Sound CV's and PR2/PR3 SoundTest modes may not be possible. Note that it is always possible to Write CV values using Operations mode or a Service Mode programming track, even if CV Read is inoperative.If the connected function loads are insufficient for CV readback or an incompatible DCC decoder is also connected, it is still possible to download a complete sound project by ...

KB724 Digitrax SoundFX Decodders on Conventional DC Power

Digitrax SoundFX decoders will automatically operate on smooth DC power unless analog mode conversion has been disabled. The sound will not start until approximately 5 volts is applied to the track.  Due to this characteristic of analog operation with a DCC decoder installed, the start up sound will not play.

KB756 DT402 & DT400 Series Throttle SWCH Key

The SWCH Key is used for entering switch control mode. Once this key is pressed, you will be prompted to select a switch address and issue a thrown or closed command. Switch control mode is used in normal operation for operating turnout machines and in set up mode for setting up option switches in the throttle and command station.

KB801 DS64 - Automated Routing

Automated Routing with DS64   Routes are a way of operating a preset combination of turnouts to predefined positions using a single Switch command. Route tables hold the Switch Address and position information that make up the Route that operates when a single command is issued. The DCS100 Super Chief can store up to 32 individual routes that consist of a "Top" address and 7 additional turnout addresses and their positions.  The DS64 has a route table that can hold up to 8 individual routes that consist of a "Top" address and 7 additional turnout addresses and their positions. Sensors ...

KB822 The Quarter Trick

If your track does not have adequate power supply to the locomotives, then the DCC signal won’t get through either. Take a quarter or screwdriver blade and go around your layout creating electrical shorts by laying the quarter/screwdriver blade across both rails every 10 feet. Your Digitrax system should shutdown when the short is present.  When the short is removed, the booster should return to normal operation. If the unit does not see a short or it does not return to normal operation after the short is removed, then you need to add more feeders.

KB857 Zephyr - Status Editing

QUICK INSTALLATION Notes for users with decoders not made by Digitrax:1. The DCS50 command station operates in 128 speed step mode. If you are using a locomotive with a decoder that does not have 128 step capability you will have to adjust either the decoder or the DCS50 so that both are using the same number of speed steps to communicate. We call this procedure status editing. You can status edit each individual decoder or you can change the DCS50’s system default by setting the DCS50’s Option Switches 21-23 and run all of your decoders with fewer speed steps to ...

KB964 Analog Loco on a Transponding Layout

Can I still operate a non-decoder equipped locomotive on my Transponding layout?Yes! Transponding will not affect operation of an analog loco (one without a decoder) on address 00. The analog loco will not transpond since it is not transponder equipped.

KB985 What is Digital Command Control?

I think this is a duplicate  Z  Needs to be beefed up or discarded. Command Control systems, both analog and digital, allow you to simulate prototypical train operation on your model railroad. With Digital Command Control you can operate multiple locomotives independently at the same time on the same section of track without a computer and without blocking or other complex wiring schemes. Digital Command Control systems use digital data packets to communicate commands to decoders that control locomotives and turnouts on the railroad.

KB990 What is Digital Command Control?

Command Control systems, both analog and digital, allow you to simulate prototypical train operation on your model railroad. With Digital Command Control you can operate multiple locomotives independently at the same time on the same section of track without a computer and without blocking or other complex wiring schemes. Digital Command Control systems use digital data packets to communicate commands to decoders that control locomotives and turnouts on the railroad.

KB577 DT400 - Playable whistle on F2 button

  Q:  I have read in some of the model magazines that the F2 button on the DT400 is a pressure sensitive playable whistle button. I have not noticed any difference in sound with the F2 button on my DT400. Is there some way to determine if this feature is present on my throttle? A:  Most Digitrax DT400 and all DT402 series throttles have the capability of implementing the playable whistle feature when used with Digitrax sound decoders.Prior to the release of Digitrax sound decoders this feature was considered as an experimental throttle feature and was not fully documented. Once Digitrax released ...

KB640 DT300 - MODE Key

The MODE key is used to move from one operational mode to another on the DT300 throttle and to dispatch selected addresses or consists to make them available for use by other throttles in the system. Lo (Loco) mode is the DT300’s default mode since most of the time you are running locomotives.Press the MODE key to cycle from Lo (Loco) mode to Sw (Switch) mode to Mu (Multi Unit) mode and back to Lo, and so on.The current operation mode will show in the middle of the bottom row of the LCD display.Dispatch: To Dispatch or offer a locomotive ...

KB248 Proto 1000 F-Units

My son & I have PROTO 1000 Diesel EMD F3A-B Sets. The powered locos are equipped with an eight-pin plug for easy decoder installation. Our problem is that we've been looking through books & have no idea what sound card & speakers we are going to need that corresponds with these type of locomotives. I was told that they would need sound cards that are from the "Early Diesel" era. If this is true, please tell me what sound cards,speakers & wires do we need to make this happen? We are fond of F-units, and the Proto 1000 F-units are ...

KB925 CV54 - Torque Compensation & Switching Speed

In FX3 decoders, CV54 is used to control the decoder's torque compensation and switching speed features. CV53 is not used in FX3 decoders.Torque Compensation improves loco performance by internally adjusting for the loss of torque caused by SuperSonicTM operation.  This feature is turned on at the factory.Switching speed gives you fast access to lower speeds used in switching operations. This feature effectively reduces the throttle's target speed by about 50% and reduces the effects of acceleration (CV03) and deceleration (CV04) programmed into the decoder by 1/4 when the user activates this mode by turning on F6.FX3 CV54 Values For Controlling ...

KB667 DT300 - L Throttle and R Throttle Knobs

The DT300 Throttle has two throttle knobs, allowing you to select and control two locomotives.  We refer to the throttle knob on the left side as the L THROTTLE and the throttle knob on the right side as the R THROTTLE. This corresponds to the L and R labels that appear on the DT300 near the throttle knobs.The throttle knobs on the DT300 use “encoders” to control speed and direction of the locomotive. The encoder can be pressed or rotated to “activate” the throttle. Pressing the throttle knob once activates that encoder. Pressing the knob twice will change the direction ...

KB669 DT300 & DT300R Differences

There are two throttles in the "300" series: The DT300 connects into LocoNet by a 7' cable. The cable allows flexibility in movement. The throttle can be disconnected to move to another point on the layout and reconnected to LocoNet without losing the acquired locomotive. The unit will also work wireless using Infrared signals when used with either a UR90 or UR91 or UR92.   The DT300R is a simplex radio control throttle with a 1' cable to connect into LocoNet. The throttle is plugged into LocoNet to select a locomotive or to program a locomotive and then can be disconnected ...

KB503 DB150 Power On LED Diagnostic Indications

Digitrax DB150 Command Station/Booster Power On LED Diagnostic BlinkingSteady on = DB150 is operating as a Command Station/Booster 1/2 sec on / 1/2 sec off = DB150 is operating as a Booster only 1 sec on / 1 sec off = DB150 is in Option (OP) mode, the Option switch is in the OPTN position 2 sec on / 2 sec off = DB150 is in Sleep mode, the Option switch is in Sleep mode Fast pulsing = DB150 is in Program Mode, the Option Switch is in PROG mode. Commands sent in this mode will program decoders that are ...

KB299 SFX0416 - Use with other DCC decoders

Wired Mobile Decoder with SoundFX™+Accessory type functions for most HO scale Locomotives. The sound project loaded into this decoder may be operated independently of any other DCC motor or function decoder. If another non-Sound FX compatible DCC decoder is connected to the track leads, then CV readback of SFX0416 Sound CV's and PR3 SoundTest modes may not be possible. Note that it is always possible to Write CV values using Operations mode or a Service Mode programming track, even if CV Read is inoperative. If the connected function loads are insufficient for CV readback with a PR3 or an incompatible ...

KB79 Case Study: Nemo Junction - The Railroad Part 1 of 9

Background The world is filled with places like Nemo Junction, a crossing between two railroads which is protected by a signal interlocking plant that also serves as an interchange point between these railroads. Cars destined for places to and from another railroad are exchanged at places like these. The interchange has been described as being the ideal model railroad industry because any type of car can be found there, heading toward places that are not on the model railroad itself. Nemo Junction is based upon a real place, a location in Illinois identified on the timetable of the Santa Fe ...

KB446 Customizing the DT400 Option #1 - Local/Global Stop

DT400 can be set up to handle stop commands globally or locally. The default is local control. With local stop, when the EMRG STOP Key is pressed once the loco on the active throttle will stop and when the EMRG STOP Key is pressed a second time, the loco on the other throttle knob will stop. To resume operation, use the throttle knobs to increase speed of the locos from 0. With global stop enabled, pressing the EMRG STOP Key will stop all locos on the layout and you will see the DT400’s track power indicator blinking on and off. ...

KB463 Circulating Ground Loops and Magnetic Induction Ground Loops

Q:  What are circulating ground loops and magnetic induction loops?  What are their symptoms and how can I fix them?A:  Like a lot of things, when you get down to the details, there can be disagreement about certain matters.Consider that the Super Chief manual states:  "To minimize the possibility of radio interference, twist all conductors."  Yet, this database has an article that states to the contrary; please see the related article in question, which is linked below.  In this situation, it must be remembered that the original manual was written several years ago and the most recent update was in 2004 ...

KB10 DT402 DigiGroup Set Up - Q & A

What is the meaning of the colored lines and bars which show up in the chart portion of the DigiGroupSetup v1.03 window after pressing the "Start Chan Scan" button? The graphics show the peak signal and average detected while you let the scan run. This may be useful in helping you setup your layout for best Duplex performance. What is the "Group ID" number which is shown in DigiGroupSetup v1.03? The Group ID is typically used in the train show environment, where there may be several wireless networks operating at the same time. The unique Group ID allows new operators ...

KB150 Turntable Control

I have an old Diamond Scale turntable; this turntable uses a rotary switch to select which stall or track you want to align the table with. It is basically a closed connection, or relay connection to select the track you want. I was wondering if it was possible to use the DS64 to create a closed connection (relay output) to activate this connection for the turntable position. Basically I want a relay output from the DS64 to be addressed by my DT400. Using throttle control This should be fairly easy, but not in the way that you envision it. The ...

KB39 UR92 - Troubleshooting Your Installation

Troubleshooting Your Installation To get the best performance out of your duplex radio installation, walk around the layout and check Duplex operation to ensure complete signal coverage. Depending on the layout size and geometry and surrounding materials it is often possible to move the UR92(s) to better cover dead-spots. Experimenting with UR92 location usually will quickly provide a position that is best for most layouts. Note that DT402D orientation and your body position may also affect range and reception. On very large layouts or layouts with problem areas, it is possible to add more than one UR92. Adding extra units ...

KB783 DS51K1 Stationary Address Programming

This procedure is best done after installation of the decoder to the turnout.  The process is "blind", so it is easier to program this decoder after installation because you can then test the operation of the turnout with its new address.  The DS51K1 can be installed into the base of the turnout or attached to the bottom of the layout near the turnout.1. Turn off track power and temporarily connect the yellow programming wire from the DS51K1 to the same rail as the black wire.2. Turn on track power.3. Using your throttle, select the address you want to program into ...

KB295 Using the SFX004 SoundBug with Other Decoders

The SoundBug track connections are shown below: The SoundBug is assigned the same address as the mobile decoder, with the only shared CV's being the address (CV01), the Configuration Register (CV29), and the headlight and momentum settings. Sound projects loaded into this decoder may be operated independently of any other DCC motor or function decoder. If another non-Sound FX compatible DCC decoder is connected to the track leads then CV readback of SFX004 Sound CV's and PR3 SoundTest modes may not be possible. Note that it is always possible to Write CV values using Operations mode or a Service Mode ...

KB899 CTX/CTY Throttles - Do It Yourself

Note: This page applies only to Challenger SetsOur customers continue to come up with different combinations & configurations to suit their individual needs so, feel free to customize your own CTX/CTY!Some users choose to hard wire 4 throttles for the 4 different channels so that the throttles are not able to change locomotives within the group.Parts List:Radio Shack Part NumbersSW-1: 6 Position Rotary Selector Switch, # 275-1386, CTX 1, CTY 1C1-C4: 0.047uf Disc Ceramic Capacitors 50v, # 272-134, CTX 2, CTY 2D1-D5: 1N4148/1N914 Small Signal Diodes 50v/100ma, # 276-1620, CTX 1, CTY 2SW-2/SW-6: Normally Open Push Button Switch, # 275-1566, ...

KB739 DT402 & DT400 Series Throttles - Fn Mode

Function or “Fn” mode is the default mode for the DT402 & DT400 throttles because it is the mode that runs your trains.In Fn mode, the throttle knobs, reverse direction keys and Y+/N- keys are used to control locos.  The numeric keypad is used to access functions for the currently active loco address.  In Sw Mode, the keypad is used to operate track switches. This means that you can continue to control your trains while turning on and off functions and operating turnouts.If a throttle has a locomotive address selected, the associated loco icon and direction indicator will be lit. In ...

KB689 Digitrax Transponding - Overview

Proven technology for bi-directional layout control without the need for modifications to your existing DCC system investment. Know the detection section and/or zone location and identification of any specific locomotive or other rolling stock equipped with a transponding device. Yes, now your dispatcher will be able to know "who you are and where you are"! Location and identification information are updated constantly on LocoNet and can be displayed on a track diagram. Adds operations mode readback of CVs to your layout. Data received by the system from mobile decoders can be used for display, automation, sound processing and much more. ...

KB385 Compatibility of LOK Sound decoders with Digitrax

I have a DCS50  Zephyr system.  I'm having a great deal of problems with it when I try to run (2) loco's equipped with LOK SOUND and DCC decoders (by ESU).  What happens is that it cuts in and out 3 to 5 times on each revolution of the train. I see it cutting out on turnouts sometimes, but not on straight track.  And sometimes when the loco's are on a hard pull, like at a sharp uphill curve.  When they cut out it just isn't the loco's, but the entire railroad.With the addition of the sound electronics, power consumption ...

KB900 DZ121 - Short Address Programming Notes

Short Address Programming Note When programming the short address (CV01) in your DZ121, the decoder will automatically set CV19 to 0, CV29 to 0, CV 55 to 80, CV56 to 30 & CV57 to 0. This is done to insure compatibility with DCC systems that only recognize short addressing (2 digit mode). When using long addressing (4 digit addressing) these CV's are not affected.After changing the short address (CV01), you will probably want to change CV29 to 06 or another appropriate value based on your operations. You can do this on the programming track or, if you forget, you can ...

KB771 DT402 & DT400 Series Throttles L (Left) & R (Right) Throttle Knobs

Digitgrax refers to the throttle knob on the left side as the L Throttle and the throttle knob on the right side as the R Throttle. This corresponds to the L & R that appears on the throttle. The throttle knobs on the DT400 use “encoders.” They give very smooth, fine speed control. In 128 speed step mode it takes four complete rotations of the knob to go from stop to full speed. When you select a locomotive that is already moving on either throttle knob, that throttle will continue to run the locomotive at the same speed and in the ...

KB392 DS64 - Example of a Yard Ladder and RR Crossing Blinking Signal

  This example is a small yard with a crossing signal at its entrance. We will use independent turnout addresses to demonstrate the flexibility that the DS64 offers. Here, route (track) 2 3 and 4 will activate the blinking light when set and the deactivation is done by resetting to route 1, the main line. The advantage of this setup is that you can easily do operating RR Crossing lights without the need for additional equipment for block detection. The turnout output utilized for the RR crossing operation is simply integrated into the route setup. In addition to the route ...

KB610 Turntables

Connecting a turntable to a DCC model railroad is easy.  Each of the tracks approaching the rotating turntable bridge should be wired with the same orientation.  The power feeds through a pair of conductive rings to a pair of electrically conductive brushes that are wired to the rails of the turntable bridge.  DCC power is fed to the turntable bridge through an AR1 Autoreverser; when a locomotive enters or leaves the turntable bridge, the AR1 properly orients the DCC signal.  Some turntable designs have a "split-ring" electrical pickup, where the two electrical contacts that power the two rails on the ...

KB172 PR3 - General Applications

What are the most common applications for the PR3? 1) Stand alone Sound FX programmer As a bench tool the PR3 is the first USB and second device designed by Digitrax for the programming of the SoundFX sound decoder. The PR3 does write to and read from the sound patterns of any SoundFX sound decoder. In addition the PR3 can write to and read from any CV of most current non sound mobile and function decoders found in today's market place. 2) Digitrax command station LocoNet to Computer interface As a layout control tool the PR3 is a second generation ...

KB164 Choosing a Locomotive for Conversion to DCC

Choose a locomotive that runs well on conventional DC power. Digital decoders cannot compensate for faulty motor operation, poor track pickup, etc. If you are not happy with the way your locomotive runs on regular DC power, installing a decoder will not make it run any better. If there are any mechanical issues with your locomotive, fix them before you install the decoder. Since you have to open up the loco anyway, do a tune up to get it running really well before you put in the decoder. Digitrax recommends using a conductive brush lubricant like Aero Car Technology's "Conducta" ...

KB137 DN143IP/DN146IP - Installation Notes

Installation Notes: 1. Do not exceed the decoder’s 500mA total function output rating. 2. If you plan to use functions F1 (traditionally a green wire) or F2 (traditionally violet), the return, also called +Common or Lamp Common, should be made via a wire carefully soldered to the Common (or blue) pin indicated as shown in Figure1. 3. To use a function output with an inductive (coil) type load, you must install a kick-back suppression diode across the connections. If controlling a coil type load, such as an electromechanical relay or motor, shutting the device off can cause an inductive kick-back ...

KB832 Zephyr - FULL Message

If Zephyr DCS50/DCS51’s display shows FuLL this means that it has reached the limit of 10 (20 for the Zephyr Xtra) locomotive addresses that it can manage at one time. If you want to select additional addresses, you will need to release one or more loco addresses before you will be able to select other locomotives to run.The DCS50/DCS51 runs a “purging” routine that helps eliminate addresses that have not been used for a period of time to make slots available for running other addresses.If you see this "FuLL" message while you are operating, you can release locos that you ...

KB839 Zephyr - Making Function 3 Non-latching

The DCS50 Zephyr normally treats Function 3 as an on/off function unless you set it up as a non-latching function like Function 2. This means that F3 can be used either as a normal function operating as an "On / Off" switch, or to control a function that only requires a momentary activation like some couplers.To set up Function 3 as a non-latching function, set the DCS50’s Option Switch 6 to closed as follows:1. Press the PROG key. The last programming mode used by the DCS50 will be displayed.2. Press the SWITCH key. The display shows the last switch used ...

KB331 Brake District Set-Up using DCS 100, DCS210 or DCS240 and a second booster

When DCC locos enter a brake section with braking on, they will receive braking commands from the command station instead of normal DCC operating commands. DCC locos in this braking section will come to a stop. When you throw the switch to allow normal DCC commands, the DCC locos will resume normal operation. Once the DCC loco has left the brake section under normal DCC power, simply return the switch to the break position so that the next DCC loco will stop in the section. This is useful if you want to have trains stop at stations around the layout ...

KB1036 DCS240 Indicator lights

The DCS240 uses different combinations ofthe PWR, PROG, NET, TRACK STAUSand USB indicator to provide a visual indication.  The indicators can show what mode the DCS240 is in as well as errors and indications.   Indications Meaning PWR GREEN winking off every 3 seconds as a “Heartbeat”  The DCS240 is powered on in Command Station Mode, Normal Operation Mode.  PWR RED winking off every 3 seconds as a “Heartbeat”  The DCS240 is powered on in Booster Only Mode, Normal Operation Mode.  PWR off blinking on GREEN or RED every 4 seconds  The DCS240 is in SLEEP mode. (GREEN = Command Station Mode) ...

KB781 AR1 Auto-Reverser Trip Current Adjustment

The tuneable trip current (TTC) adjustment allows you to set the current at which the reversing section reverses when the train crosses the gap into the section. This allows you to improve the operation of your reversing sections.The tuneable trip current is adjustable from .25 amps to 8 amps. Turning the TTC screw clockwise increases the current trip point and turning the TTC screw counterclockwise decreases the current trip point. The total adjustment is approximately one half revolution of the TTC adjustment screw. The TTC adjustment is made using a full load on the reversing track--the total number of locomotives/cars ...

KB864 Zephyr - Control Panel

The front panel of the DCS50 Zephyr has a throttle knob & direction control lever, indicator lamps & display, which give status indications and operate your railroad. Before you select and run a locomotive, take a few minutes to look at the DCS50's controls and display.1. The Throttle Knob is the large silver and black knob on the right side of the DCS50. The Throttle Knob controls locomotive speed from STOP to FULL speed. Turn it clockwise to increase speed and counter clockwise to decrease speed.2. The Direction Control Lever is the small silver lever (located on the left side of ...

KB317 Function Remapping Trix GG-1

The Trix GG-1 is a fine die cast locomotive model which is equipped with a sound decoder. As produced by the Trix factory in Germany, the sound functions are: F0 Normal headlights F1 Bright headlights F2 Cab lights F3 Sound of main relay F4 Low speed switching range (switching acceleration / braking delay off) F5 Bell F6 Horn, continuous blast F7 Sound of pantograph being raised and making contact with the wire F8 Sound of blower motor F9 Sound of switching relays F10 Sound of cab radio F11 Sound of couplers F12 Sound of clickety clack railroad track Digitrax operators ...

KB551 DS54 Trigger Task Defined

The DS54 is a powerful stationary decoder, which can be used to control devices in several different ways. Within the DS54 electronics are four independent sections. Within each section are three independent elements: Switch_, Aux_ and Output_. Each element can act independently or in conjunction with one or more elements within that independent section. (Note: The Switch_ element can be accessed from the input connector and the Output connector of the respective section.) Each of these elements can perform any one of several different actions. The actions are determined by two variables: trigger and task. The relationship of the Trigger ...

KB76 PR3 - Running with JMRI on Mac OS 10.5

Running the PR3 and PR3 Xtra with JMRI on MAX OS X. 1) Plug in the Digitrax PR3 to a USB port on an Intel-based Apple computer running MAC OS version 10.5 or later.  Within about a second the Green "USB" led on the PR3 should glow steady green showing a USB connection has been established with the MAC. 2) Open system profiler or About This Mac and under hardware>USB there should be a entry "Vcom" showing that the USB port has enumerated OK. This optional step is simply to check the PR3 device was found.3) Go to JMRI sourceforge ...

KB1010 Configuring your WTL12 as an AutoReversing Booster/Throttle.

You can operate reversing sections manually or automatically with Digitrax. You must double gap (completely isolate) both ends of the reversing section just like with any other layout. If you choose manual operation, use a DPDT switch or relay to handle the polarity change as the loco enters and leaves the reversing section.   If you choose to use to completely automate the reversing section, power the reverse loop with a booster and power supply and the main layout with another Command Station and power supply. The WTL12 when running as your command station will not auto-reverse.  To configure your ...

KB891 LifeLike Proto 2000 Number Board Light Problems

Life-Like Proto 2000 locomotives with number board lights have the number board bulbs wired to their 8-pin DCC plug using pins 4 and 5. This causes no problems with DC operation but causes a path from the rail pickup to the gray motor lead when a decoder is installed resulting in erratic operation and decoder failure.This is a known problem in the Proto 2000 GP60, SD60M and LifeLike GP38-2.  The DH165L0 uses a current limiter set to control one incandescent bulb on the front (FOF) and one on the rear (FOR) and putting the removed number board bulb on either ...

KB805 DS64 - Setting Board ID for Additional DS64s

When using more than one DS64 in a DCC environment, you must assign a Board ID to each additional DS64 so that each one has a unique Board ID.You will need to set the DS64's board ID if you are planning to use the DS64's 8 inputs with a computer, system throttle, or other smart device on your layout that needs to know when a turnout has been manually thrown or closed via a particular DS64.You can use the 8 inputs on the DS64 to control the operation of the 4 outputs that control your turnouts.  For example, you can ...

KB981 Was the NMRA DCC Standard based on the Lenz System? Isn't that a proprietary system?

After considering the various alternatives available at the time, the NMRA's DCC Working Group found that the signaling techniques used by the Lenz System had what they were looking for and used a communications protocol that offered the greatest future growth potential. While the signaling techniques were based on the Lenz design, numerous improvements were made and a packet format that is much richer in features was ultimately adopted. While the Standard has its roots in the Lenz system, it is not based on any proprietary equipment or information.If you look at the early NMRA DCC working group FAQ's it ...

KB408 Introduction to the Digitrax SE8C Signaling

Security ElementsThe Digitrax Signaling System is organized around the concept of what we call "security elements", which are similar to what U.S. prototype railroads call "plants" or "interlockings". The Digitrax SE8C signal decoder displays aspects for up to 32 heads for 8 individual security elements (plants) using either a LocoNet Throttle or a computer with compatible software. When used with associated occupancy detectors and compatible software, the SE8C can be set up to protect the turnout with signals as shown by the example below. Note that trains can move from A to B, A to C, B to A or ...

KB453 DT402 & DT400 - Low Battery Power Indicator

While it is running as a tetherless throttle, the DT402 and DT400 R and D versions automatically check the power available to the throttle each time a battery is inserted and each time it is plugged into or unplugged from LocoNet. The battery's voltage will be displayed in the text area of the throttle briefly each time the throttle is plugged in or is unplugged from LocoNet. When you plug in to LocoNet the number displayed will be the power provided by LocoNet. This value will be between 9 & 15 volts. Other characters will also be displayed in the LCD depending on ...

KB494 Upgrading Old Starter Set

Q:  I just purchased a used Digitrax set consisting of a DB150, UT2 and a PS515 for a very low price. What do I need to add to bring this up to current standards? A:  Because of Digitrax LocoNet, it is easy to add the latest components to upgrade on older starter set.  What you purchased was originally called a Genesis Starter Set.  The PS515 did not come with it but it is the perfect power supply for the DB150.   Your next step depends on what you want to do with your railroad.  In this case, the components you have will be ...

KB1037 I’m getting a “StealZap” or message on my DT402 rev 2 throttle. What is this?

This is a feature that helps prevent having the same address selected on multiple throttles and creating unexpected operations.  When you steal you are truly stealing control of the locomotive instead of sharing it. When using a DT402 R2 throttle with an Advanced Command Station featuring expanded slots, each throttle ID is associated with the Loco Addresses it has selected.  With a when you select a Loco that is selected on another throttle the second throttle will take ownership of the Loco and it will be deselected from the first throttle. By first throttle will display “StealZap” meaning it has ...

KB1047 Powering your DCS240 with a PS2012

Connecting a PS2012 DC power supply to an “Advanced Booster”  DCS240 and sharing with older Command Stations and Boosters: The 2016 US DOE external power supply Efficiency requirements effectively require using DC input power and supplies for new-design products including our Advanced Command Stations/Boosters.     Digitrax does not recommend sharing a suitable DC supply for an Advanced type unit like a DCS240 with older Legacy Digitrax Command Stations/Boosters designed to run on AC output transformers. This is because the common Booster Ground (typically pin 4’s) and negative power return wires have a diode offset in non-Advanced (AC input)  units ...

KB107 Con-Cor N-Scale Aerotrain Decoder Installation

Application Note: Steps needed for installing the DN143IP mobile decoder into the Con-Cor N-Scale Aerotrain "DCC Car". The image above shows the “DCC Car” for the N scale Con-Cor Aerotrain, which is the 1st car behind the loco. It shows the holes in the underbody, above which a speaker can be mounted for a sound decoder installation. The recommended Digitrax sound decoder would be our SFX0416, but to use this decoder the seats will need to be removed. There is a pocket that is 16mm wide, 36mm long and 3mm deep designed for a speaker above the underbelly and under ...

KB1011 Troubleshooting Guide for Digitrax Sound Decoders

Digitrax SoundFX Decoder Troubleshooting Guide This troubleshooting guide assumes that you are working with an operating Digitrax system that is able to run trains and that the locomotive you are troubleshooting is operational and has a Digitrax sound decoder and speaker installed correctly.  If there is no sound, first make sure the decoder is not muted: Press the Function 8 (F8) key, and make sure F8 is OFF.  Function 8 is used to toggle between sound active (F8 OFF) and mute (F8 ON). If there is no sound and the locomotive won’t move when the address is selected on your ...

KB256 DH165A0 - Installation Instructions

1. Carefully remove the locomotive's shell from the frame. Notice the orientation of the circuit board inside so that you can install the decoder in the same orientation. (Figure 1) 2. Remove the 10 black plastic plugs from the lightboard that secure the wires to the PCB. There are 4 plugs (retainers) on each end and 2 on the side for the motor connection. Remove the red and black wires, carefully noting where each wire originally connected to the PCB. Remove the lightboard itself by pinching the black plastic release tabs and pulling the board up and off of the ...

KB78 Case Study: Nemo Junction - Basic Wiring Part 2 of 9

Although this is a simple railroad, it will have some advanced features. When the railroad's sectional modules are first assembled, the electrical connections are simple. The railroad will be controlled with a DCS50 Zephyr, using a PM42 Power Manager for short circuit protection. One section of the PM42 will control the inner oval of track, a second section of the PM42 will control the outer segment. This is done so that if a train derails on one loop, the train operation on the other loop will not be affected. Because the DCS50 is rated at 2.5 amps, the PM42 must ...

KB174 Brass Locomotives

I have several old brass locos and they have Pittman motors. I have tried DH163 Decoders and blown two. I believe that they draw excess current that exceeds 1.5amp cont. Is there an HO mobile decoder with the same size physically as DH series, but has higher current ratings? Suggestions? While it is possible that the motor may be drawing too much current, it also may be possible that the motor brushes are not isolated from the frame of the locomotive. It also would be helpful for you to determine the stall current of the locomotive to see if the ...

KB776 DT402 & DT400 Series Throttle Display Basics

The DT402 & DT402's screens are an LCD (Liquid Crystal Display) that is designed to show you what you are controlling with the throttle.  It also facilitates programming and other features of the LocoNet system. 1. The handheld has two throttles called the left throttle (L) and the right throttle (R).2. There are two direction indicators. One for the L throttle and one for the R Throttle. If the direction indicator is lit, and there is smoke over the loco icon there is an address selected on that throttle.3. The direction indicator with blinking smoke indicates which throttle is currently active. The ...

KB391 DS64 - Sensor Activated RR Crossing Lights with the addition of a BD4

You can automate grade crossing signal lights with block occupancy sensors. Install a BD4 to detect track occupancy as shown in the figure below. Other than removing the Op Sw35 commands from the routes used in the related article example, there is no additional programming needed for the DS64. Sensor operated occupancy detection requires that all rolling stock be equipped with resistor wheels for proper detection or that the detection section is longer on each side of the RR Crossing than the full length of a train since only the locomotive will draw current. A lighted caboose on the end of ...

KB627 Tower 55 locomotives-Programming a 4-digit address using Digitrax Zephyr Xtra (DCS51) or Zephyr (DCS50)

Note: The programming shortcut for 4-digit addressing outlined in the Digitrax Zephyr manual will not work to program the Tower 55 decoder in any programming mode on the Zeyphr throttle due to a programming timing issue with the DSC50. Please use the procedure referenced in this bulletin to access this feature.Note: If the DCS50 or DCS51 is being used as a command station with a DT400/DT400R throttle connected via the Loconet ports, then the programming shortcut for 4-digit addressing outlined in the DT400/DT400R throttle manual will work to enable the 4-digit address capability of the decoder when using the DT400/DT400R throttle ...

KB615 Soldering Basics

Basic tools for soldering: a soldering iron, solder, wire cutters, wire strippers, tweezers, heat sinks, etc. This photo does not show an example of desoldering braid which is useful for touch ups and removing mistakes. If you are building a model railroad, you will need to learn to solder. This skill is used for attaching track feeds to the rails to provide power to the layout, for installing decoders in locomotives, for building locomotives and signals and much more. Manufacturers minimize the need to solder where ever possible by using screw connectors, board repalcement decoders and plugs for installing decoders. ...

KB59 BDL168 - Terminology

Here are some terms that you might find useful as you work with the BDL168. Direct home wiring is a layout wiring method where each power district and its booster is electrically isolated. The track within each power district uses a "common return" wiring method for occupancy detection and/or power management. Direct home wiring is the wiring method recommended by Digitrax for safety reasons & also because it makes detection work more prototypically. Power district is the power wiring, track, components and equipment attached to that wiring, driven by a single properly isolated booster. The track for a power district ...

KB489 Programming DCS100 or DCS200 Option Switches with a DT300 throttle

Instructions below are for both DCS100 & DCS200 (DCS200 omitted in text for clarity).1. Refer to the DCS100 Option Switch Table to decide which option switches you want to change. Also note that there are special instructions for OpSw's 36, 37, 38, & 39. 2. Move the MODE toggle switch on the front of the DCS100 into the "OP" position . The LocoNet Railsync will go inactive & all other boosters plugged in to LocoNet, including the one that is built into the DCS100, will shut down. 3. Disconnect LocoNet from the DCS100 you are configuring. 4. Connect your DT300 ...

KB492 Programming DCS100 and DCS200 Option Switches with a DT400 Series Throttle

Note:  These instructions are the same for DCS100 & DCS200 (DCS200 omitted for clarity).1. Refer to the DCS100 Option Switch Table to decide which option switches you want to change. Also note that there are special instructions for OpSw's 36, 37, 38, & 39. 2. Move the MODE toggle switch on the front of the DCS100 into the "OP" position . The LocoNet Railsync will go inactive & all other boosters plugged in to LocoNet, including the one that is built into the DCS100, will shut down. 3. Disconnect LocoNet from the DCS100 you are configuring. 4. Connect your DT400 ...

KB196 PR3 - Software Setup for Microsoft Windows XP

When the PR3 is powered up and properly operating, the green ‘USB’ light on the PR3’s control panel will be blinking steadily and the red ‘STAT’ will be blinking momentarily. Make sure the supplied SoundLoader Installation CD is inserted in your PC's CD player. Plug the PR3’s USB cable into a vacant USB socket on your PC . Depending on which operating system you have on your PC, you will next see a dialog box appear on your PC’s monitor. The procedure we document in the following pages is for Windows XP, if you have Windows Vista®, Windows 2000®, or ...

KB549 Trix HO Mikado Steam Locomotive CV Settings

The following CV settings have been found to give great performance from the Trix Mikado. These settings were discovered by Norm Stenzel after much trial and error.  Once the loco was set with the following CV values this locomotive operated very nicely with the sound synchronized to its movement. CV 2 = 4         Default Value = 4      START VOLTAGECV 3 = 0         Default Value = 8      ACCELERATIONCV 4 = 0         Default Value = 6      DECELERATIONCV 5 = 35       Default Value = 64    MAX VOLTAGECV 6 = 20       Default Value = 22    MID POINT VOLTAGECV 29 = 6      Default Value = 4      CONFIGURATION ...

KB1056 LNWI Security Considerations: Enabling and Customizing WPA2 Security

LNWI Security Considerations: Enabling and Customizing WPA2 Security The LNWI has the option of enabling WPA2 security to require a passcode to connect to the LNWI SSID.  The primary purpose of this passcode is to limit access to the LNWI in a public setting.  This is designed to operate in a similar function to the passcode options for Digitrax Duplex Radio. Using an unsecured connection poses minimal threat to LocoNet access as the LNWI only utilizes a limited number of LocoNet commands.  The LNWI does not have access to programming capabilities or other advanced LocoNet capabilities on your layout.  No ...

KB7 Automatic Reversing Sections

DCC Automatic Reversing SectionsVirtually all automatic reversing will fall into 3 categories with the wiring principles for all being the same:1. Reverse Loops2. Wyes3. TurntablesDCC has the ability to automatically reverse sections of track we call Reversing Sections while our trains are running and not affect the direction or speed of the trains. This is because we put a constant square wave AC current on the track and control the trains (locos) by sending messages to them (actually to receivers we call decoders) to tell them what to do such as start, stop, change directions, etc. . We are thus ...

KB927 CV65-CV95 - 28 Step Loadable Speed Table

When you are using a throttle to control a locomotive, you will notice that as you increase and decrease the speed, the loco responds to the change in throttle settings according to the relationship between motor voltage applied and the throttle setting.  This is called the throttle response curve.  Decoders are shipped from the factory with a linear throttle response curve.  This means that as you increase the throttle setting from 0 to full speed, the loco will look like the default curve in this diagram.If you want to create a more realistic throttle response curve, you can set up ...

KB32 DT402 - Battery Installation

For normal tethered operation, the DT402 series throttles do not need a battery. To use your DT402/R/D as an infrared or radio throttle, you must install a 9 volt battery. When you install the battery, the throttle will report the battery voltage then show the last display screen. We recommend that you remove the battery from throttle if it is unplugged from the system to conserve battery life. The battery can be stored inside the DT402/R/D by removing the battery and putting it back in the battery compartment with the polarity reversed. Be careful here, see the diagram below for ...

KB34 DT402 - Controls

Remember, the EXIT Key will take you back to the Fn Mode for Normal Loco Operations.

KB86 Static Electrical Discharge & Mobile Decoder Installations

I noticed on one of the forums that some guy was saying that static discharge was a major problem when working with decoders... Is this REALLY a problem? The operative word is was. Back in the early days, back in the late 1980's and early 1990's, it was an identified problem. Since DCC was not really a player in that era, this means that it involved M

KB139 Powering the DS52

Can the DS52 be powered directly from a 13.8 v DC external power supply instead of the rails? No. Screw Terminals 4 & 5 are used to not only supply power to the DS52 from the track but also are the path that is used to both program the DS52 and to operate the DS52 via a throttle or computer program.

KB141 Wiring Harnesses

I have numerous locomotives I wish to convert to DCC. In order to spread the cost out over time I would like to install the connector/harness and add the decoder at a later date. Is it possible to buy the connector/harness assembly separately? Yes, there are several harnesses which are part of the Digitrax Easy Connect systemThis System Included the:DHWH - 9 pin to bare wires wire harnessDHDP - 9 pin dummy plugs to convert for analog operationDHWHPS - 9 pin to DCC medium plug short harness 1"DHWHP - 9 pin to DCC medium plug long harness 3"DHAT - 9 pin ...

KB142 SE8C - Voltage Output

My signals are supplied with current limiting resistors and require 12v max to operate. What are the voltage outputs from the SE8C and does this differ depending on the supply (15V AC or 12V DC). The output voltage is 5 volts, regardless of the input power. It is powerful enough to drive LED's, but it cannot handle incandescent lamps.

KB146 DZ125IN - Function Outputs

The DZ125IN is set up at the factory to control two function outputs. The DZ125IN is configured to control the forward and reverse lights on the locomotive through the white lead and yellow lead using Function 0 (F0F-forward and F0R-reverse) for directional lighting. Both function outputs can be easily set up with Digitrax FX3 lighting effects or as standard on/off functions with the following operational qualifiers: 1. Forward or Reverse direction of travel, or 2. Whether F0 is on or off, or 3. Both direction of travel and whether F0 is on or off, or 4. Whether the locomotive is ...

KB260 DT100 Locomotive Selection

ENGINE SELECTIONPlace locomotive on the tracks controlled by the command station.1. Turn the throttle knob you want to run a loco on about a quarter turn (this lets the controller know you want to address that side.)2. Push the "Sel" Button3. Turn the throttle knob you have selected until the left numbers of the display match the locomotive number you wish to run. (No decoder = 00)4. Push "Sel" again.5. Repeat for the other throttle.If the number "33" appears it means that locomotive is unavailable (usually under the control of another throttle)These simplified DT100 operating instructions courtesy of Alan Mitchell

KB320 DCS100 - Net Indicator

The NET indicator is a red LED that displays information about what the DCS100 sees on LocoNet. When your layout is wired correctly and LocoNet is operating properly, the NET indicator will be on and it will flicker off any time a good LocoNet message is detected by the DCS100. The table below explains the patterns you will see for this indicator.

KB324 DCS100 - Off Line Indicator

The DCS100 automatically shuts down when the heat sink temperature rises to around 45 to 50 degrees Celsius and the OFF LINE indicator will glow red. The DCS100 automatically resumes operation when the heat sink cools down to approximately 40 degrees Celsius. The OFF LINE indicator will also be lit when there is no track status. This is normal and you should not be alarmed.

KB359 LNRP - Q&A

1) Does the LNRP terminate and re-time the LocoNet data signal in both directions? Yes 2) Does the LNRP repower the LocoNet data lines for each segment? Yes 3) What happens to the signal on a protected segment when there is a fault on an adjacent segment? Nothing, it keeps going 4) What happens RailSync on a protected segment when there is a fault on an adjacent segment? Nothing, it keeps going 5) What do the various diagnostics/error indicators really do? They monitor and report the protected sides. A Digitrax PS14 power supply is required for correct operation.

KB367 DT400 - Erratic Behavior

I have a DCS100. I do not understand why my DT400's speed increases (all the way up to 99) sometimes when I plug it in. Also, sometimes the Loco number (when selected when this is taking place) will increase too. There is no control enabled when this is taking place. If I plug in a DT100 it operates normally. One of the buttons on the DT400 may be stuck, leading to this behavior. Take a look at the control panel of the DT400 and you will probably see this stuck button since it will not be in a fully returned ...

KB430 DT400 - Strange Locomotive Lights

The headlights of my locomotive aren't acting properly. If you can’t control the operation of the lights in your locomotive with the DT400 (in default 128, or 28 speed step mode), be sure that the decoder is programmed in advanced 28 speed step mode. Do this by programming CV29 with a decimal value of 06.

KB433 DT400 - EMERGENCY Stop

If the layout starts to “get away” on you, either PRESS the PWR Key followed by the N- Key or, turn the track power to “SLEEP” on the command station. Either way, the layout will stop to give you a chance to regain your composure. To resume operations where you left off, press the PWR Key followed by the Y+ Key

KB434 DT402 & DT400 - EXIT Key

  If your DT402 or DT400 display isn’t showing you what you expect based on the manual, press the EXIT Key to return to normal operating mode-Fn. Then try the throttle task again.

KB439 Customizing the DT400 Option #4

Option # 4 sets the throttle ID of your throttle. Each throttle in your LocoNet system can have its own unique ID to support advanced LocoNet functionality. Products that use this feature will usually require each throttle in your system to have a unique ID. We recommend changing this ID only when specifically directed to do so by the manufacturer of a LocoNet compatible product that requires unique throttle IDs for operation. You may use any ID in the range of values x00-x7F (hex) and you must be sure that every throttle in your system has a unique ID #.

KB600 Rule 17 Headlight Dimming

Rule 17 refers to how a locomotive engineer operates the locomotive's headlights while running the train. Rule 17 is part of a railroad's standardized rulebook.  Rule 17 varies from railroad to railroad. Typically, it requires dimming the headlight when the locomotive is standing in a siding waiting to meet another train, passing through passenger stations or moving within yard limits.  Program CV49 to 104 to set Function 0 to implement Rule 17 dimming.      

KB636 DT300 - Infrared Emitters

Your DT300 has two infrared LEDs in the cable end of the throttle case. These emitters send infrared signals that can be used by LocoNet compatible Infrared receivers such as UR90, UR91 & UR92 to give you tetherless operation via infrared signals.

KB641 DT300 - SEL Key

The SEL key, called the Select Key or Select/Set Key, is used for selecting loco addresses on to the throttles. This is sometimes referred to as “assigning locos to throttles.”This key is also used to select or complete (set) an operation.

KB647 DT300 - Mode Indicator

The mode indicator, located at the bottom center of the LCD, shows the DT300’s current mode of operations. The DT300 automatically defaults to the Lo (Loco) mode and returns to this mode after about 6 seconds of inactivity in Mu (Multi Unit) or Sw (Switch) modes.

KB662 DT300 - Option Switch 4 (Op#4)

Option # 4 sets the throttle ID of your throttle. Each throttle in your LocoNet system can have its own unique ID to support advanced LocoNet functionality. Products that use this feature will usually require each throttle in your system to have a unique ID.We recommend changing this ID only when specifically directed to do so by the manufacturer of a LocoNet compatible product that requires unique throttle IDs for operation. You may use any ID in the range of values x00-x7F (hex) and you must be sure that every throttle in your system has a unique ID #.

KB671 DT300 Display Modes

  The DT300 controls devices and operations in different modes:

KB685 Can the Transponding feature be turned off in decoders that have integrated transponders?

Yes. Digitrax decoders with integrated transponding are shipped with transponding enabled but this does not affect the operation of existing layouts not outfitted for transponding.

KB743 DT402 & DT400 Series Throttle Enter Key

The ENTER key is used to complete the current throttle task and return to Fn mode for normal operations.

KB744 DT402 & DT400 Series Throttle Exit Key

The EXIT Key is used to exit the current throttle task without making changes. Pressing this key will usually return the DT402 and DT400 series throttles to Fn mode for regular locomotive operation.

KB755 DT402 & DT400 Series Throttle Direction Reverse Keys

The L & R Direction Reverse Keys change the direction of travel of the loco on the related throttle when the throttle is in Fn (Normal Operation) Mode. The R Direction Reverse Key changes direction of the address on the “R” or Right Throttle. The L Direction Reverse Key changes direction of the address on the “L” or Left Throttle.  You can also reverse the locomotive by double clicking the throttle knob.

KB766 DT402 & DT400 Mode Indicator

The mode indicator, located at the bottom center of the LCD, shows the DT402/DT400 series throttles' current mode of operations. The DT400 automatically defaults to the Fn mode & returns to this mode whenever the EXIT Key is pressed. The Mode indicator usually shows what the numeric keys are associated with. For example, in Fn mode, any entry on the numeric keypad will affect functions. In Sw mode, keypad entries will change turnouts and in Lo mode, entries on the keypad will enter loco address numbers, etc.

KB821 Zephyr-Exit Key

HELP!!!!!!!!If your Zephyr DCS50 display isn't showing you what you expect based on the manual, press the EXIT key to return to normal operating mode. Also make sure that the "Power" is on. Then try the throttle task again. If you think you might have made an inadvertent change to one of the factory settings in either the decoder or the command station, try resetting everything to the factory settings and try the task again. Please see the related articles (below).

KB910 DT100 Address Programming Instructions

These simplified DT100 operating instructions courtesy of Alan Mitchell, tested by the Raisin Valley Model Railroad Club in Blissfield, Michigan! PROGRAMMING THE ADDRESS INTO A LOCOMOTIVE WITH A DT100Place locomotive to be programmed on program track with the system turned on.1. Push "Run/Stop" Button, hold it down and push the Function Button. Release both buttons (The digital display should say "Ad:--")2. Turn the right hand throttle knob to select the address you wish to program into you throttle3. When the number appears, push "sel" (the display should say "Page" followed momentarily by "Good"NOTE: DT100 is out of production.

KB960 Digitrax Transponding vs. Lenz RailCom

Transponding is proprietary technology of Digitrax Inc.  Transponding works with existing DCC compatible layouts. RailCom is proprietary technology of Lenz Elecktronik. This is sometimes referred to as "bi-directional communication."  It requires modifications to existing DCC equipment for proper operation.The two methods are not compatible, they do not use the same technology.

KB961 Transponding and signaling systems

Digitrax transponding works with Digitrax signaling system products. Transponding is not required to operate signaling systems however, the provision of transponding allows the possibility of the signaling system being able to automatically take control of trains that violate a signal aspect. Transponding can also be used to eliminate the "pushy pusher" problem that is characteristic of hardware implemented signal influenced speed control schemes.

KB983 Why use a digital system rather than an analog system?

1.  Digital technology gives extremely reliable operation and the technology is almost infinitely expandable without causing backward compatibility problems (analog systems are inherently more restrictive). 2. Digital systems make wiring simple and easy to install. 3.  Digital systems encode information sent from the command station to the decoder as numbers grouped into packets, new types of packets can be added to a digital system to send more information thus extending the existing system without causing backward compatibility problems.

KB984 What will DCC do for me and my railroad?

This needs to be beefed up or discarded  Z Simply put, DCC will let you "run your trains, not your track." DCC gives you the freedom to bring your railroad to life! With DCC you have truly prototypical operation at your fingertips.

KB376 Example Control Display

I am not sure what example railroad he is talking about.    ZHere is a control panel display example for our example railroad using Railroad & Co.: This is the way that an actual railroad dispatcher would control our example railroad. Although the three sidings are not controlled by the dispatcher, they are still shown because the positions of their points have a material affect upon train operations. A train approaching an open turnout would be put at risk, so the position of these turnouts is considered to be part of the control system. These sidings would be manually controlled by ...

KB536 What is a Programming Track?

Q: What is a programming track? A:  A programming track is a section of track that is used to program the mobile decoders in locomotives.  Sometimes it is called the service mode track or service mode programming track.  It must be electrically isolated from the rest of your layout and connected to the Prog A and Prog B terminals of your command station.  The programming track can be completely separate from the rest of the layout or can be isolated by double gapping and using an electrical switch to allow locos to move from the programming track to the mainline before and after programming.   Usually ...

KB495 Run a four digit locomotive address with UT1 Utility Throttle

Although the UT1 can only handle addresses between 00 and 99, it can be used to operate one four digit locomotive address. 1. On the UT1 dial up 992. On a DT100, DT300 or DT400 series throttle, dispatch the four digit address you want to run on the UT13. On the UT1 press the ACQ (acquire button) to run the four digit addressNote that dispatching is a special state and the first UT1 throttle to press the Acquire button after the dispatch from another throttle will acquire that address to run.

KB28 DT402 - Mode Indicator

The mode indicator, located at the bottom center of the LCD, shows the DT402’s current mode of operations. The DT402 automatically defaults to the Fn mode and returns to this mode whenever the EXIT Key is pressed. The Mode indicator usually shows what the numeric keys are associated with. For example, in Fn mode, any entry on the numeric keypad will affect functions. In Sw mode, keypad entries will change turnouts and in Lo mode, entries on the keypad will enter loco address numbers, etc. The following table provides a list of the Mode indication displayed, the mode name and ...

KB156 DZ125 - Function Outputs

The DZ125 is set up at the factory to control two function outputs. The DZ125 is configured to control the forward and reverse lights on the locomotive through the white lead and yellow lead using Function 0 (F0F-forward and F0R-reverse) for directional lighting. Both function outputs can be easily set up with Digitrax FX3 lighting effects or as standard on/off functions with the following operational qualifiers: 1. Forward or Reverse direction of travel, or 2. Whether F0 is on or off, or 3. Both direction of travel and whether F0 is on or off, or 4. Whether the locomotive is ...

KB232 CV29 - NDOT

  CV29 is assigned a single value which chooses a combination of specific effects: 1. Speed step control. 2. Speed table On or Off. 3. Analog mode conversion On or Off. 4. Normal Direction of Travel (NDOT). 5. 2 digit addressing or 4 digit addressing. Normal Direction of Travel, or NDOT for short, lets you set up your locos to run either long hood forward or short hood forward. Because with DCC the decoder determines which way the loco will move independent of track polarity, you can set up either direction as forward depending on the prototype. (Not all decoders ...

KB325 DCS100 - Track Status Indicator

The TRACK STATUS indicator shows that there is voltage on RAIL A & RAIL B terminals. The color indicates the type of signal:  If it is orange the track is getting DCC signals with no analog zero stretching.  If the color is green or red then a stretched zero signal is being used to operate a conventional locomotive. When zero stretching is present, the DCC decoder equipped locomotives will read their digital commands normally and perform as commanded. If the Track Status LED is not lit there is no voltage on the track, the track power to the DCS100 may ...

KB613 Throttle Jacks vs. LocoNet Jacks

The jacks on the front and sides of the UP5, UR92, UR91, UR90, and LNRP front panels are Throttle Jacks and should only be used for connecting throttles to LocoNet.  They should not be used to connect to other LocoNet devices.  The jacks on the back of these units are LocoNet Jacks that are used for connecting LocoNet devices to the network.  Technically speaking! These units were designed to have the FRONT jack's second Railsync differential signal run as a diode-or'ed power source (for throttles).  This means that some cable orientations and power loads could cause unexpected operations in downstream LocoNet devices ...

KB1034 AR1 autoreversing with the Zephyr Xtra

When using an AR1 with the Zephyr Xtra, we suggest you change Option Switch 18 to Closed (OPSw18='c').  Option Switch 18 extends the DCS51 booster short circuit shutdown time from 1/8 to 1/2 second.  By increasing this Option Switch setting to 1/2 second, this allows the AR1 to change the track polarity before the DCS51 booster reacts to the momentary short caused when the train passes over the reversing section gaps.   To change Option Switch 18, do the following:   Press PROGRAM Press SWITCH Press 1 Press 8 Press c (CV-WR, lower right) Press EXIT   You will still ...

KB48 BDL168 - Option Switch Table

The option switches and settings you can use to customize your BDL168 are indicated in the table below. These option switches on your BDL168 are set up using a Digitrax throttle's SWITCH commands. (This can only be done with a Digitrax LocoNet throttle or equivalent software). SWITCH mode is normally used for operating turnouts by issuing closed ("c") or thrown ("t") commands. In the case of your BDL168, each switch address is a BDL168 option switch. The following table shows what each OpSw is used for when it is set for thrown or closed. Factory settings are indicated by shaded ...

KB683 Will Digitrax Transponding affect my existing boosters, track wiring or locomotive pickups?

Q:  Will Digitrax Transponding affect my existing boosters, track wiring or locomotive pickups?A:  No. Digitrax transponding is designed to be sued with DCC compatible boosters made by all DCC manufacturers, track wiring & locomotive pickups without causing any damage or operational problems with existing DCC track signals. Unlike other "bi-directional" systems, no high current spikes are used by Digitrax transponding that can cause problems with boosters and wiring. Digitrax transponding does not require the replacement or modification of existing control equipment or infrastructure.

KB246 DS64 - Multiple Output Pulses

Why does the DS64 generate multiple output pulses for a single command? I get between 2 and 5 pulses over a period of about 2 seconds. Option Switch 01 determines the type of turnouts that you can operate, static or pulse. The Factory default is for "Pulse". Option Switches 02, 03, 04, and 05 set the pulse length. OpSw 02 = Closed the pulse width is 200ms (milliseconds). OpSw 03 = Closed, the pulse width is 400ms. OpSw 04 = Closed, the pulse width is 800ms. OpSw 05 = Closed, the pulse width is 1600ms. All, or any combination of ...

KB50 BDL168 - Using with Power Managers

The BDL168 is designed to be used with power management devices such as PM42. The BDL168 is designed to operate “downstream” of the Digitrax boosters and power management devices. The BDL168 is the "last" device in the chain from booster to power manager to BDL168. It is connected directly to the track detection section. There should be no other connections to any detection section that will draw track power or the detection section will always show occupied. If a device is used to switch off power feeding the BDL168 and the track it is connected to, for example, a PM42 ...

KB634 DT300 - Power Save Mode

If an untethered DT300, operating as a tetherless throttle, detects no user throttle activity for about 3 minutes it will enter power save mode. The display will show: The throttle may flash the normal Lo (Loco) Mode screen about every 60 seconds. This happens when the throttle “pings” the system to let the command station know that it is still part of the system. This keeps the system from releasing that locomotive back to the system and making it available to be selected by another throttle.Any key strokes or movement of the throttle knobs will bring the DT300 out of ...

KB500 DS54 - Standard Turnout Feedback

  Setting up DS54 for Standard Turnout Reporting The creation of a feedback circuit for standard turnout reporting is simple. Connect a normally open set of contracts attached to the switch machine, a normally open set of contacts of a micro switch monitoring the turnout throw arm, or the normally open contacts of a relay monitoring the switch machine to the common (green) and switch (red) wires to the desired DS54 output circuit. The following two diagrams indicated the two most common switch machine configurations plus the contact configuration for turnout reporting.  Note: The location and type of contacts available for ...

KB507 SE8C - Signals On Non-DCC Layouts

Q: I would like to know about SE8C and signals on non-DCC layouts. A:  The SE8c is a signal driver for your layout. You can operate signals manually with any LocoNet Throttle and Command Station. Or, in your case, the SE8c can drive signals automatically with detection and compatible computer software such as RailRoad & Co. or JMRI.You will need detection devices to identify the presence of trains, a computer interface such as the PR3, a computer program supplying the signaling logic and the SE8c driving the signal heads themselves. Note that in a LocoNet environment, the SE8C supports detection: DS01 ...

KB888 Installation of Digitrax Decoders in HO Scale Atlas RS1, RS3, RSD4/5

Many thanks to Bob Dattore for this application note!This app note details using a DN142 decoder for the installation.  This decoder is no longer in production but the following decoders would work as well:  DN135D, DN163, DZ123, DZ125, DZ143.  Any decoder that is small enough to fit could be used.The Problem:  Atlas RS1's (and RS3's & RSD4/5's) are hard to install Digitrax decoders in. There is no easy drop-in or light board replacement with back-emf capability.I have installed several Atlas Dual Mode decoders in these popular hard to fit narrow, low hood diesels with ease, by replacing the original light ...

KB1021 DS51K1 compatibility with Kato Turnouts

The Digitrax DS51K1 Stationary Decoder is for use with single coil Kato powered turnouts only.  These turnout include the following: 20-202 N Scale #6 Left Hand Powered 20-203 N Scale #6 Right Hand Powered 20-210 N Scale Double Crossover Powered * 20-220 N Scale #4 Left Hand Powered 20-221 N Scale #4 Right Hand Powered 20-222 N Scale #2 Wye Powered 2-860 HO Scale #6 Left Hand Powered 2-861 HO Scale #6 Right Hand Powered 2-850 HO Scale #4 Lef Hand Powered 2-851 HO Scale #4 Right Hand Powered * The 20-210 Double Crossoever requires a total of 4 DS51K1 ...

KB1069 Differences in the DS74 from the DS64

Differences in the DS74 from the DS64: Up to date and compact LocoNet design with customer IPL/firmware field update capability using DigiIPLII. All plug-in connections. Can support on expansion header up to 4 DSXCP1 fascia SW control panels with SW direction indicator LEDs. 8 internal LocoNet integrated System routes, that can be conveniently edited on a DT602 with latest IPL update. Configurable unit Base switch address when on layout. No need to remove from layout to service/configure. Automatic DS74 switch address overlap detection, and correction capability when editing with DT602. Indicates internal IPL Sub-version loaded to latest DigiIPLII rev 2.9 ...

KB478 PM42 - Power Management of an Auto Reversing Section

Q:  What is the preferred way of protecting a reverse loop with circuit breaker management and still having automatic reversing? A:  There are two ways of protecting a reversing section with a circuit breaker and reversing section controller. 1.  Use one PM42 (circuit breaker manager) and one AR1 (automatic reversing section controller). 2.  Use two PM42s (one as a circuit breaker manager and one as a reverse section control). The following diagram displays both methods: a) The first method (left), is where one section of a PM42 configured for circuit breaker operation feeds one or more AR1s (automatic reversing section controller), or b) The second method ...

KB576 CV 58 Master Volume Control

The master volume control CV is CV58, its values range from 0 to 15.  The factory default value for this is 09.Digitrax SFX decoders have a factory default value of 09 set for CV58.  This works well for 32 ohm speakers.The decoder will reset to this value whenever you do a decoder reset of CV8=8. Digitrax SFX decoders built for use with 8 ohm speakers should have this value changed to 4 or 5 for best operation value of 4 or 5, since the decoder may not supply enough current at high volume/drive levels.Your results may also depend upon track voltage present. Kato USA says ...

KB1053 LNWI Advanced Options

LNWI Advanced Options Status LEDs: The LNWI has two status LEDS Green ID indicator and a Red OPS indicator.  The state of these indicators can be interpreted to provide status information and also some useful diagnostic insights. Table 1: Status LEDs LED Status Indicates Green ID indicator mostly lit, winking OFF every 3 seconds LNWI is powered and connected to LocoNet Green ID indicator mostly off, blinking ON every 3 seconds LNWI is powered and LocoNet is not connected or sleeping Green ID indicator winks OFF LNWI received a good LocoNet Message Red OPS indicator blinks ON LNWI received a ...

KB213 LocoNet Adapters LA1 & LA2

The first Digitrax system to use LocoNet was Big Boy. Each Big Boy system came with a LocoNet Adapter 1 (LA1) or LocoNet Adapter 2 (LA2). Documentation for these units was minimal, but is included here. LA1 LA-1 came with a simple card: LA-1 LocoNet Adapter Use this cable to connect your DB100 to your DT200 command station unit and to your LocoNet command bus. The LA-1 allows you to connect more than one throttle to your Big Boy System. You only need one LA-1 in a Big Boy System. If you are upgrading to Big Boy from Challenger, you ...

KB912 LT-1 Decoder Testing Procudures

1. Strip the insulation from the red, green, black and yellow wires on the harness. The blue and white wires are not used and may be cut off the harness if you wish.2. Twist the red and yellow wires together. Twist the black and green wires together. 3. To test motor operation, hook up the wires according to the directions in the Digitrax Decoder Manual. One of the two center LEDs will light as the motor voltage increases from the decoder. Change direction and the other LED will light. 4. To test other decoder functions connect the LT-1 to the ...

KB581 BD4 - Connecting to a DS54

  How do I connect the BD4 to the DS54? The BD4 is a block occupancy detection device designed as an add-on device that can take advantage of the LocoNet hosting capability of the DS54 stationary decoder. It is connected in this way: The installation of a BD4 is relatively simple. Looking at the BD4, you will find a 5-point terminal block on one end and two (LED1 and DS1) 10-pin (5x2) headers on the other. There are three termination areas: a) The 5-point terminal block (left) is for the interconnection between the rail power source and the rails. b) ...

KB103 Troubleshooting DB150 Shutdowns

If the DB150 unit shuts down occasionally due to a track short circuit: 1. Correct the short circuit condition and the booster will resume normal operation. 2. Turning off the booster when a short occurs is not necessary since it will re-start automatically when the short is cleared. If the DB150 unit shuts down frequently: 1. Move the DB150 so that the heat sink has a flow of cool air. 2. Place the DB150 out of direct radiant heat like sunshine or a room heater. 3. Try direct cooling by using a small fan to blow air onto the heat ...

KB533 BD4 - Connecting to a DS64

How do I connect a BD4 to a DS64? The BD4 is a block occupancy detection device designed as an add-on device that can take advantage of the LocoNet hosting capability of the DS64 stationary decoder. It is connected in this way: The installation of a BD4 is relatively simple. Looking at the BD4, you will find a 5-point terminal block on one end and two (LED1 and DS1) 10-pin (5x2) headers on the other. There are three termination areas: a) The 5-point terminal block (left) is for the interconnection between the rail power source and the rails. b) The ...

KB665 DT300 - Option Switch 3 (Op#3)

The factory setting for Op#3 for all DT300 throttles is Op#3=x01.LCD Backlight Brightness SettingThe backlight intensity can be set for off, low, medium or high intensity. The brightness of the backlight affects battery life, the brighter the LCD, the shorter the battery life.Note: When the DT300 is untethered, the backlight automatically reduces brightness by one setting to conserve battery power.Fast Clock FormatThe fast clock can be set up to display either 12 hour format or 24 hour format. The factory setting is 12 hour format.Recall Stack DepthThe DT300 recall feature can be set to keep a list of the last ...

KB742 DT402 & DT400 Series Throttle EMRG STOP Key

Your DT402/DT400 throttle comes from the factory set for “Local” Stop. When you press the EMRG STOP Key , the loco address that is active on your display (the one with the blinking smoke) will stop.When you press the EMRG STOP Key again, the loco address on the other throttle of your DT400 will stop.You can use the OPTN t Key to change the EMRG STOP to “Global” Stop.With global stop option enabled, pressing the EMRG STOP Key will stop all locos on the layout and you will see the throttle's track power indicator blinking on and off.To resume operations, press ...

KB513 Zephyr - Non-USA Power Supply

Note: Zephyr (DCS50) has been superseded by Zephyr Xtra (DCS51) which is available in an EU version that comes with the appropriate power supply.  This article only applies to the original Zephyr (DCS50)Q: I´m a foreign model railroader, and I want to buy a Zephyr without power pack. The instruction manual says that I can use a 18 Volt DC trafo in order to power the Zephyr. Can you suggest a way to connect a Zephyr DCS 50 to German current (220/50)? A:  In the North American market, Digitrax recommends the use of a dedicated PS315 power supply or equivalent for use ...

KB852 Loco Won't Stop or Start As Expected

Whoa!!!!!Each locomotive on your railroad has a mobile decoder which receives the command control signals from the command station and operates the locomotive motor accordingly.  The performance of mobile decoders can be adjusted by changing the Configuration Variables (CV's) of the decoder.  You can improve the speed performance of a locomotive by adjusting its start speed (CV02, V-Start), its mid-range speed (CV06, V-Mid) and its top speed (CV05 - V-Max).  You can also adjust the acceleration (CV03) and the deceleration (CV04).If the deceleration CV value you set for a particular loco is very large, this can make it look like ...

KB179 Zephyr - Q&A, DCS50 as a Booster

If a Zephyr has been switched to run as a booster/throttle (no command function), can it still be used to program locomotives on the programming track? No, when using the DCS50 as a booster, the programming outputs are disabled. Programming is a function of the command station only, so when the Zephyr is toggled to booster mode, it loses the programming function. If a Zephyr has been switched to run as a booster, does the throttle still work? Yes, but you must assign an unique throttle ID to the Zephyr which is acting as a booster. Assigning Throttle Identities To ...

KB651 What is the Digitrax LocoMotion System?

Your locomotives look like the real thing, Digitrax LocoMotion™ System makes them run like the real thing, too!   128 speed step control.   Smooth deceleration to stop before changing direction when locomotive is reversed. No sudden, non-prototypical stops!   Torque compensation for the smoothest operation ever.   Momentum with acceleration and deceleration settings.   Set normal direction of travel for your loco.   Switching speed feature for quick access to slower switching speeds.   Simple 3 step speed tables are easy to set up.   Advanced 28 step speed tables with 256 level resolution.   Scaleable speed stabilization feature. ...

KB177 Function Outputs for DN163A0

The DN163A0 is set up at the factory to control six functions. The unit is prewired with two golden-white LEDs set up for directional lighting as F0F/F0F+ for the front light and F0R/F0R+ for the rear light. Functions F1 (Green), F2 (Violet), F3 (Brown) and F4 (White/Yellow) can be used by soldering a wire from the pad for the function you wish to use to the lamp (or other function) you wish to control. The wire colors indicated are the standard color code used in the industry (you can use any color you like). These colors are important if you ...

KB703 UP5 Front Panel Installation

While it is possible to use RJ12 telco jacks as throttle jacks on LocoNet, the UP5 is much simpler to use and looks much more professional on the front of the layout. The UP5 is shipped as a kit that must be assembled.  You will need to attach the front panel to the circuit board using the screws provided as shown below before installing the entire unit on your layout.  If your front panel does not fit at a "perfect" 90 degree angle to the circuit board, this is will not affect the functionality of the unit.Make sure to line up the Track ...

KB323 DCS100 - Mode Switch & Scale Switch

The MODE and SCALE switches are used to configure the DCS100 for your railroad. The 3 MODE switch settings are:  RUN is for normal operations. OP is used to customize the DCS100 by changing its option switch settings. SLEEP is used to shutdown the system and all throttles that are plugged in to the system. SCALE Switch (O/G HO N) This switch sets the maximum track voltage limit. 1. Set the DCS100's SCALE switch to the scale you are running (N, HO, O\G). Use the lowest setting (N, HO, or O/G) that will run your layout. 2. Set the MODE switch ...

KB375 Super Empire Builder & Slot=max

If your throttle says "slot=max", this means that the Super Empire Builder's capacity to handle operating locos is full. The DB150 can run up to 22 addresses at the same time. If you have the "slot=max" message, be sure that all locos that are not running have been released from throttles. This will free up room inside the DB150 for other locos to run. A DCS100 command station can run up to 120 locos so, if you are having this problem often, you should consider adding a DCS100 to your LocoNet system. To Release Locomotives 1. Use the throttle to ...

KB123 Function Outputs on the DN163K1D

The DN163K1D is set up at the factory to control six functions. The unit is prewired with two white LED's set up for directional lighting as F0F/F0F+ for the front light and F0R/F0R+ for the rear light. Functions F1 (Green), F2 (Violet), F3 (Brown) and F4 (White/Yellow) can be used by soldering a wire from the pad for the function you wish to use to the lamp (or other function) you wish to control. The wire colors indicated are the standard color code used in the industry (you can use any color you like). These colors are important if you ...

KB1015 Power Xtender Q & A

My sound decoder has a capacitor, why do I need a PX112? The capacitor that came with your Digitrax sound decoder is designed to hold up sound operation in the presence of brief power interruptions.  It is not designed to keep the locomotive’s motor and lights running.  Our ears are very sensitive to sound interruptions so, the capacitor on your sound decoder will prevent most of these drop outs on average quality track.  Most people don’t even notice the small pauses in a locomotive’s movement and the small flashes of the lights when the track power is interrupted.  If you ...

KB1071 PM74 display and LocoNet message control Option Switches

The PM74 OPSW41= C will change the 4 DS1-4 led display, so each DS led now reports the same way the PM42 leds did. This is a Legacy option provided for users who want the PM74 indications to be similar to the PM42. The default OPSW41 =T has the DS led light ON for resistance Occupancy detection within that DS, and will flash when a Transponder is present in that DS. These 2 additional DS detection capabilities and indication were NOT present in the PM42. Whatever the OPSW41 state is, LocoNet messages will report Power state/action,  Occupancy and Transponding messages to a connected LocoNet, ...

KB382 DN163K2 - Function Outputs

Is this part of the instructions sheet?  If so, we don't need it here?  ZIThe DN163K2 is set up at the factory to control six functions. The unit is prewired with two golden-white LEDs set up for directional lighting as F0F/F0F+ for the front light and F0R/F0R+ for the rear light. Functions F1 (Green), F2 (Violet), F3 (Brown) and F4 (White/Yellow) can be used by soldering a wire from the pad for the function you wish to use to the lamp (or other function) you wish to control. The wire colors indicated are the standard color code used in the ...

KB831 Zephyr - Error Messages

The DCS50 Zephyr displays three types of error messages: Short circuit shutdown occurs when the DCS50 detects a short circuit in the power district where it is connected to the layout. This can be a loco that has derailed or picked a switch or some other conductive material lying across the tracks. In this case you will see “o”s walking across the display from left to right. Once the short is cleared, the DCS50 will resume normal operations. Current overload occurs when the DCS50 has reached its 2.5 Amp current limit. In this case you should run fewer locomotives or ...

KB56 BDL168 - 44-Pin Connector Pinout Configuration

BDL168 Pin Out Configuration: Notes: 1) All connector pins are paired top (component side of the BDL168) and bottom (solder side of the BDL168) except 11/M and 12/N. For 6 Amp current rating with 3 Amp connector pins, track/zone wires must be connected to both pin pairs: e.g. Zone A = pins 1 & A (See Figure below): 2) Letters G, I, O & Q are not used as pin designations on the connector. 3) Power connections should be made to a power supply dedicated to BDL168 use only. Multiple BDL168 units can be supplied by a single shared supply ...

KB40 DT402D - Joining Your Throttle to the Duplex Group

Join Your Throttle to the Duplex Group 1. Connect a DT402D Duplex Radio Throttle with an installed battery to the front RJ12 jack of the UR92 for about 2 seconds. 2. Disconnect the DT402D from the LocoNet jack. The DT402D will briefly display an 8 character Duplex Group name and the Channel number being used by the UR92 Group. The actual Duplex Group name is not important at this point, it is simply used by the DT402D to join this Duplex group on its particular Duplex channel (#11 through #26). 3. Now that the DT402D has joined the Duplex group, ...

KB154 DZ125PS Installation in Kato H0-Scale F40PH

1. Carefully remove the locomotive’s shell from the frame. Notice the orientation of the shell to the frame (Figure 1) so that you can reinstall the shell correctly. 2. Remove the dummy plug from the locomotive’s DCC-ready socket. (Figure 2) The jumper plug allows the loco to operate on a standard DC track or in analog mode on a DCC track. Pin 1 is marked for proper orientation of the decoder. 3. The DZ125PS has a short, 1" harness with a DCC 8-pin plug on the end of it. The plug is oriented so the pin for the orange wire ...

KB315 Resetting Super Chief

There are times, when all else has failed, that it is best to simply start over. To reset Super Chief, you can use the Chief's option switches to start fresh. *Special Instructions for DCS100 Op Switches 36, 37, 38, & 39 For Op Switch #36-#39 to work properly:   In this example, a complete reset will occur (Option Switch 39). 1. Place the DCS100's MODE toggle switch on the DCS100 in the Center OP position 2. Press the SWCH key on the DT400/DT402/DT500 3. Press 3 and then press 9 4. Set the OpSw of choice to c by pressing the ...

KB29 DT402 - Turn track power on and off

The Track Power indicator on your DT402 display shows the track power status. There is also a Track Status light on your Command Station. If the track power indicator is lit then track power is on. To turn the track power on or off: 1. Press the PWR key on the DT402. You will see a screen similar to the one below. You will now be able to toggle the track power on/off: 2. Press the N/- key to toggle the track power off. The Track Power Indicator on your DT402 and on your Command Station will go off. 3. ...

KB481 PM42 - Automatic Reverse Section Control

  Q:  What is the basic configuration and Option Switch (OpSw) settings for each of the four sections of the PM42 when configured for automatic reverse section control? A:  The PM42 is a 4 section multi-purpose device where each of the four sections can be individually configured to act as either a circuit breaker, or auto-reverse section controller or DPDT relay. When configured as an auto-reverse section controller, the PM42 adjusts the rail phasing of the reversing section it controls whenever a locomotive, or car with metal wheels, bridges the gaps between the rails of that reverse section and an adjacent non-reversing section ...

KB987 General Command System Troubleshooting and Tools

This article stops in a strange place??  We need to find the rest of it and split it up into meaningful chunks.  Also needs meta stuff Troubleshooting in General:Regardless of the guides, manuals, tips, suggestions, experts or whatever, troubleshooting can occasionally degenerate into a vast chasm of darkness and confusion.  It would be impossible to cover all the areas that have, can or may cause problems. This is a general guide to identifying and resolving problems with Digitrax Complete Train Control.  Keep Good Records:Although it may seem to be a pain while setting up your Digitrax system, keeping layout records ...

KB249 DH165Q1 - Function Outputs

The DH165Q1 is set up at the factory to control six function outputs. The DH165Q1 is configured to control the forward-headlight F0F/white lead and reverse-headlight F0R/yellow lead for directional lighting. These two headlight function leads are current regulated for LEDs or lamps, with factory setting of approx 15mA, with no resistors required. Cut the ADJ link to increase headlight current to approx 30mA- see fig 5. Functions F1 (Green), F2 (Violet), F3 (Brown) and F4 (White/Yellow) are full track voltage and can be used by soldering a wire from the pad for the function you wish to use to the ...

KB5 DN163A1 - Function Outputs

The DN163A1 is set up at the factory to control six functions. The unit is prewired with two golden-white LEDs set up for directional lighting as F0F/F0F+ for the front light and F0R/F0R+ for the rear light. Functions F1 (Green), F2 (Violet), F3 (Brown) and F4 (White/Yellow) can be used by soldering a wire from the pad for the function you wish to use to the lamp (or other function) you wish to control. The wire colors indicated are the standard color code used in the industry (you can use any color you like). These colors are important if you ...

KB41 UR92 - Installation/Quick Start

The UR92 is simple to install and begin using in your new or current layout. 1. In most cases a UR92 should be situated near the physical center of a layout and will typically cover a circle of about 300+ feet (~100 meters) across, which will be adequate for most layouts. Some layouts may require additional UR92s for adequate signal coverage. 2. Connect the PS14 DC power supply to UR92 via the DC power jack on the side. The green and red LEDs should blink and then the red LED should stay on. 3. Connect the UR92 to your working LocoNet ...

KB11 DH163 Series - Function Outputs

The DH163 series decoders are set up at the factory to control six function outputs. The DH163 is configured to control the forward and reverse lights on the locomotive through the white lead and yellow lead using Function 0 (F0F-forward and F0R-reverse) for directional lighting. Functions F1(Green) and F2 (Violet) are part of the harness for easy hookup. F3 and F4 are also available on the decoder board. These can be accessed by snipping the shrink wrap and peeling it back to expose the solder pads that control these functions: To use these functions, solder a wire from the pad ...

KB254 DH165K0 - Function Outputs

The DH165K0 is set up at the factory to control six function outputs. The DH165K0 is configured to control the forward-headlight F0F/white lead and reverse-headlight F0R/yellow lead for directional lighting. These two headlight function leads are current regulated for LEDs or lamps, with factory setting of approx 15mA, with no resistors required. Cut the ADJ link to increase headlight current to approx 30mA- see fig 5. Functions F1 (Green), F2 (Violet), F3 (Brown) and F4 (White/Yellow) are full track voltage and can be used by soldering a wire from the pad for the function you wish to use to the ...

KB70 Apex & Hypotenuse AR1 Layout Wiring Example

My layout is the Apex & Hypotenuse design, from the Atlas design. I was wondering where would you suggest I wire the AR1. We remember this layout design, if for no other reason than its ingenious complexity. This railroad initially appeared in the Custom Line King Size Plan Book - H0 Railroads You Can Build, originally published by Atlas Tool in 1966. This book was yet another collaboration between the late John Armstrong and illustrator Thaddeus (Tad) Stepek. This railroad must have required a certain level of dexterity by the operator since the reversing segment is actually two different return ...

KB88 DS64 Option Switches - Overview

The DS64 is a powerful stationary decoder that can be used to control different devices on your railroad. It can be used on both command control and analog model railroads. The DS64 is configured by the settings of different Option Switches (OpSw's), listed below: OpSw01 - Solenoid or slow motion devices OpSw02 - Pulse Timeout, 200ms OpSw03 - Pulse Timeout, 400ms OpSw04 - Pulse Timeout, 800ms OpSw05 - Pulse Timeout, 1600ms OpSw06 - Output Auto Power Up OpSw07 - Factory-default Reset OpSw08 - Regular/Extended Startup Delay OPSw09 - Timeout Option OpSw10 - Throttle/Computer Option OpSw12 - Sensor Input Option OpSw13 ...

KB364 DH165A0 - Function Outputs

The DH165A0 is set up at the factory to control six function outputs. The DH165A0 is configured to control the forward-headlight F0F/white lead and reverse-headlight F0R/yellow lead for directional lighting. These two headlight function leads are current regulated for LEDs or lamps, with factory setting of approx 15mA, with no resistors required. Cut the ADJ link to increase headlight current to approx 30mA (see figure below). Functions F1 (Green), F2 (Violet), F3 (Brown) and F4 (White/Yellow) are full track voltage and can be used by soldering a wire from the pad for the function you wish to use to the ...

KB499 DS54 - Exact Turnout Feedback

  Setting up DS54 for Exact Turnout Reporting The creation of a feedback circuit for exact turnout reporting is simple. Connect a normally open set of contacts attached to the switch machine, a normally open set of contacts of a micro switch monitoring the throw arm, or a normally set of contacts of a relay monitoring the switch machine power to the common and switch input of the DS54 input connector. When the turnout is closed these contacts must be closed. Connect a normally open set of contacts attached to the switch machine, a normally open set of contacts of a ...

KB614 BDL168, PM42 & SE8C Recommended Wiring Procedure For 44 Pin Connector

  Do you have a recommend wiring procedure for the 44-pin edge connector on the PM42 and SE8C?PM42, PM4, BDL168, BDL16, BDL162 & SE8C use a 44-pin edge connector. Connecting wires securely to this connector requires soldering skills. For connections to the 44 pin connector, Digitrax recommends using 16 gauge stranded wire. For all other soldering connections, Digitrax recommends 14 gauge (AWI) stranded wire for electrical connections on your railroad. 1. Use individual short lengths of 16 gauge wire to connect to the 44 pin connector. 2. Strip and tin both ends of the wire. 3. Bend one end into ...

KB814 Powering DS64

  There are three different ways to power the DS64.  Track power (Trk A and Trk B), Auxiliary power (AX1(-) and AX2(+)) and power through the rear modular power connector.  Connect the Trk A and Trk B screw terminals of the Power and Track Connections to the corresponding Rail A and Rail B track connections.  The PS14 power supply can be used with Auxiliary or the rear modular power connector.  The DS64 requires 300mA for proper operation.  Only one DS64 can be powered per PS14.  A generic DC power supply between 12-16vdc and 300mA can be connected to a DS64 ...

KB856 Zephyr - Setting Speed Limit

To control the speed of a locomotive:1. Select the loco address on the Zephyr.2.  Place the reverse lever [2] into either forward or reverse.3. Turn the Throttle Knob  [1] clockwise to increase speed and counterclockwise to decrease speed. Setting Speed LimitsYou can limit the speed on any locomotive controlled by the DCS50. This feature is very useful if you are running your layout with young children who want to make the trains GO FAST!!! By setting a reasonable speed limit on the throttles used by the children, everyone can have more fun with the trains.To set a “speed limit” for ...

KB38 UR92 - Resetting Factory Defaults

Resetting Factory Defaults You are unlikely to encounter a problem that will require a factory reset. One such instance may occur if you set a password for your Duplex Group name and forget what it is. Resetting to factory default condition is an easy way to correct the situation. Note: If you have more than one UR92 in your layout, you will want to disconnect all of them to do a full factory reset on each unit as follows. Once they have been reset, reconnected to your LocoNet, and allowed to renegotiate a common Group name; you can change the ...

KB250 DH165K1A - Installation Instructions

DH165K1A Board Replacement Decoder Fits Kato SD40-2, AC4400 1. Carefully remove the locomotive’s shell from the frame. Note the orientation for proper reinstallation (Figure 1). 2. Remove the four track power pickup wires clipped to the lightboard at mid point (Figure 1). 3. Unscrew the two screws securing the lightboard and lift it from the frame. (Figure 2) 4. Remove the lightboard by pulling it gently straight up, off the motor clips. (Figure 3) 5. Decoder installation is the reverse of what we’ve done so far. Snap the decoder into place over the motor clips. Be sure motor clips are ...

KB656 DT300 -Stealing an Address That is In Use by Another Throttle

Stealing an Address that is in use by another throttle If you try to select a loco address that is already selected on another throttle the DT300 will display “Steal?=Y” in the text area. This is a safety interlock to prevent operators from taking control of locos that are already selected on other throttles. Occasionally it is necessary to override this interlock to gain control of a loco that is “lost” for whatever reason. This override is called stealing and can result in having a single loco address selected on two different throttles at the same time.To Steal An Address With ...

KB928 Three Step Speed Table-CV02, CV06, CV05

Three Step Speed Table CV02 V-Start (Start Voltage) CV06 V-Mid (Mid Point Voltage) CV05 V-Max (Maximum Voltage)When you are using a throttle to control a locomotive, you will notice that as you increase and decrease the speed, the loco responds to the change in throttle settings according to the relationship between motor voltage applied and the throttle setting. This is called the throttle response curve. Decoders are shipped from the factory with a linear throttle response curve. This means that as you increase the throttle setting from 0 to full speed, the loco will look like the default curve in ...

KB1068 UT6 Throttle Options Settings

UT6 Throttle Option Settings Throttle ID# Option Name Factory State ID01 Ballistic Knobs With Ballistic tracking, the faster you increase or decrease the throttle knob the faster the data changes in the throttle. When Off the speed step increase is per encoder notch. on ID02 Key clicks Off disables clicks for key press and encoder changes on ID03 Duplex RF allow Off will disable Duplex Radio capability. on ID04 IR allow Off will disable IR capability. on ID05 Fast Clock show On will show fast clock. off ID06 24Hr Clock mode On changes the clock mode from 12Hr to 24Hr. ...

KB843 Zephyr - Reading Back CV Values

Your DCS50 can read back the CV data values programmed into your decoders. You will use your programming track for reading back CV data values.To read back CV values using a programming track:1. Be sure that only the locomotive you want to read back is on the programming track.2. Press the PROG key to enter programming mode. The Zephyr DCS50 will display one of the programming modes available. Once the mode you want to use is on the screen you can go to step 3.For example, to use Paged mode stop pressing the PROG Key when the following screen appears:3. ...

KB511 Direct Home Wiring

Direct Home Wiring: A wiring system where the DCC booster powers each rail via an individual wire.  Each booster is wired to it's own track power section and there is no electrical connection between boosters. This means that each power district is double gapped and is connected to it's own booster.  The boosters are in turn connected via LocoNet to the command station providing one source of commands for the entire layout.Digitrax recommends using only Direct Home Wiring for all Digitrax layouts. Non command control layouts typically use common rail wiring as part of their control method. This means that one rail ...

KB304 Kato RDC's and DN143K2

Photo Courtesy Kato, USA The DN143K2 replaced the earlier DN122K2 as a custom decoder designed for the Kato RDC in N-Scale. This is not a particularly easy installation and there have been some reports of problems with the headlights. Paul Lator has some experience with this installation, and this may be of help to you: "The wiring with the DN143K2 works well if you do not route the wires over the top of the seating in the RDC, rather completely disassemble the unit, mount the decoder in it's designated location then run the wires through the drive shaft tunnels. Place ...

KB876 Roco Digital Crane with Digitrax Throttle

This crane is fully controllable by your Digitrax system. The crane itself turns 360 degrees, the boom raises and lowers, the hook raises and lowers. An electromagnet and searchlight are optional and can also be controlled from your throttle. Only one can be used at a time, but they both come in the same package.Here is a step by step guide to using it with your Digitrax system.The decoder has an address of '08' and is a 28 speed step decoder - selecting the crane requires doing what is known as a "status edit". Hit SEL, turn a knob to ...

KB1041 DCS240 USB is lit Blue, but Utilities will not work

When I hook up my USB cable to my PC the DCS240’s blue USB led turns on, but Digitrax DigiIPL II, LocoMon and SoundLoader II utilities do nothing when opened. What is the problem? The blue USB led lit on the DCS240 means that the complex USB Enumeration and startup sequence has successfully completed.  Be sure to select the correct COM port number that is now associated with this DCS240 in the software you are trying to use.  You can see this COM number appear in the “Ports (COM & LPT)” entries of e.g. the Device Manager function of Windows, ...

KB552 Can you have two command stations on the same layout?

Q: Can you have two command stations on the same layout? A: No. If you try and run with two command stations you will experience what we usually refer to as "shocking, horrifying results." Two command stations on a single layout is often a problem with modular layouts. You can disable the command station capability in Digitrax Command Station/Boosters so that you can use them as boosters only to add more power to your layout.For the DCS100 to disable command station mode:1. Set Op switch 2 to "c" 2. Set Op switch 5 to "t" 3. Set it to auto ...

KB318 DCS100 - CMOS Battery Replacement

When you hear 7 beeps when power is applied to your DCS100, you need to replace the CMOS battery. The DCS100 will continue to operate, even if this battery is not present, but all your memory settings and option switch settings will not be remembered when the DCS100 is powered down. To replace the CMOS battery without losing any memory settings: 1. Remove the DCS100 input power & disconnect all DCS100 leads. 2. Open the DCS100 case:  a. Remove the two screws on the top and bottom of each side of the case. b. Slide the gray front panel off ...

KB238 Zephyr Xtra, Super Empire Builder Xtra or Super Chief Xtra? What's the difference among the Digitrax Sets?

  Zephyr Xtra                             Super Empire Builder Xtra                            Super Chief Xtra                                                Command Station DCS51 DB150 DCS100 Current Rating 3 Amps 5 Amps 5 Amps or 8 Amps Throttle DCS51 DT402 DT402 Throttle Controls Single Knob, Direction Switch Dual click encoder throttles Dual click encoder throttles Function Control F0-F29 F0-F29 F0-F29 Keypad Full Numeric Keypad Full Numeric Keypad Full Numeric Keypad Display Large LED Multi-line Backlit LCD Multi-line Backlit LCD Throttle Capacity 20 22 120 Loco Capacity 20 22 120 Loco Address Range 00-9000+ 00-9000+ 00-9000+ Stationary Address Range 01-999 00-999 00-999 Turnout Position Reporting Yes, last command sent Yes, last ...

KB534 Short Circuit when adding a DB100 or DB150 booster to a DCS100 or DCS200 Command Station

Q:  I recently split my layout in half, with a DB150 acting as a booster powering one side and a DCS100 powering the other. I'm trying to reconnect the bus feeders to the rails, which all worked properly before the split. Now when I reconnect the feeders there is no short indication, BUT when a loco goes over the insulated gap between the two sections, a short occurs. A:  This is a common issue when the first booster is added to a DCS100/DCS200 command station. MOST DCS100/DCS200 command stations come from the factory set with Rail A & Rail B connections that are the opposite ...

KB625 Tower 55 DCC Equipped Locos- Testing a Four Digit Address Reset with DCS50 Zephyr

Testing for Tower 55 DCC Equipped Locos after 4 Digit address programming:Note these instructions are the same for both DCS50 Zephyr and DCS51 Zephyr Xtra1. Press the LOCO key on the DCS50. (The LED display should begin flashing)2. Enter the 4-digit address that was programmed in the procedure above using the numeric keypad. (The LED display should be flashing “####” with the # symbols replaced with the 4-digit address that was keyed in)3. Press the LOCO key on the DCS50. (The LED display should display “####” solid and the locomotive sounds should start up)4. Select FORWARD with the direction knob ...

KB556 CV29 - Addition Method for Hexadecimal Users

CV29 controls many aspects of the locomotive, including its decoder address (including two or four digit address) , normal direction of travel (NDOT), whether the locomotive opperates at 28 speed steps or 128 and others. Some older Digitrax throttles use hexadecimal notation for programming.  This article is presented for the benefit of those who may still be using these throttles.  CAUTION: if you are NOT using a DT100 or DT200, please disregard this article to avoid confusion.The Addition Method The table below shows each switch and its value if it is on or off. Notice that if the switch is ...

KB264 DB150 Reset Instructions

There are times when it is necessary to reset the Super Empire Builder. Because this is a system reset, there are special instructions: There are different levels of system reset. OpSw 36: Clears all mobile decoder information, including locomotive consists. OpSw 38: Clears the locomotive roster (such as when you receive a "slot=max" error report). OpSw 39: Full reset, clears all internal memory states. The factory default setting for all DB150 option switches is t or "thrown" The Initial Procedure 1. Determine which DB150 option switch you want to change, 36, 38 or 39. 2. Move the Mode toggle switch on ...

KB886 Installation of Digitrax Wired Decoders in a Kato GP35 Diesel HO

Note: These instructions cover the hardwired installation of any Digitrax decoder with wires into a Kato GP35 H0 Diesel. Currently, the recommended decoder for current production GP35's from Kato are the DH163K0 board replacement decoder.  Using the board replacement decoders are much simpler and cleaner installation than the one described here.Tools Needed for Decoder InstallationYou'll need a few simple tools:1. A soldering iron, preferably temperature controlled.2. Solder3. Screwdriver4. Small diagonal cutters for cutting and stripping small wire5. TweezersMotor Isolation for Kato GP35Carefully remove the loco's shell and weight.To isolate the motor, disconnect the brass strips (motor brushes) from the track pick up ...

KB120 Decoder Installation in the H0-scale Con-Cor Pioneer Zephyr

Application Note: Con-Cor HO-Scale Zephyr steps needed for the DZ125PS decoder installation Step 1: Carefully remove the body from the frame. There are four clips along each side of the body. (See red arrows) We have found if you start at the rear of the body with a small flathead screwdriver and carefully pry the body outward to remove the back clip, you can move the screwdriver forward to release the others. Once the body is completely removed, carefully lift the light board from its holders on the bulkheads. (See blue arrows) Be very careful as the pins that hold ...

KB415 DCS 100 & 200 Front panel

The 5 Amp DCS100 and the 8 Amp DCS200 share the same front panel layout. There is a variety of indicators, switches and connectors: Power Input The two POWER IN terminals on all Digitrax boosters & command stations are the power input connections. Power On Indicator This green LED indicates that the power to the DCS100 is on. Ground Terminal The terminal marked ground provides electrical safety features and an RF ground reference for minimum radiated noise. This should be the ONLY point of any DCS100 installation that is connected to the AC safety ground pin provided on most 3 ...

KB67 BDL168 - Setting Up Board ID

When the BDL168 is connected to LocoNet, it will communicate coded detection information to the system. If you wish to report BDL168 status to LocoNet and attached devices or computers that can interpret these messages, you will probably want to set up a unique board address for each BDL168. This is done so that the BDL168 Board ID does not conflict with the Board ID of other devices on the railroad. Board addresses can range from 01 to 999. It is recommended that you make a record of the addresses you use for all devices connected to your layout. Setting ...

KB521 What is "Smooth" DC?

The term smooth DC is used to describe the power provided to the layout by conventional model railroad power packs (analog transformers). Traditional model railroad power packs convert household line current into 12-18 volt current to power your model railroad. Voltage is supplied to the track, and as the voltage increases, the speed of the locomotive's motor increases, which makes it run down the tracks at faster speeds. Some power packs put out only AC (alternating current), while others put out DC (direct current) and AC (for accessories such as track switches and building lights). AC powered trains tend to ...

KB403 Steps to take to locate UR90, UR91 & UR92 for best performance

Follow these simple instructions to determine the best location/s on your layout for installing your UR panels for the best possible infrared or radio reception. With LocoNet, you can use Infrared, Duplex Radio and Simplex radio individually or in any combination on your layout.You'll need to be able to observe whether your command station is receiving commands from the UR panels when you are installing infrared or radio receivers and transceivers.  Your Digitrax command station makes it easy to determine when the system is receiving a signal and when it is not.  You can observe the NET LED and the Track Status Indicator or your ...

KB112 Reset Procedure for Mobile Decoders

CV08 is the factory reset CV for all FX3 decoders and also the Manufacturer ID CV for all decoders. This procedure is performed on a programming track. To reset all CV values to their factory default, program CV08 to a value of 008/x08 while the locomotive is on the programming track. To reset all CV values except for 28 step speed tables to their factory values set CV08 to a value of 009/x09. Earlier Digitrax decoders must be reset manually, CV by CV. This procedure may or may not work with other manufacturer's decoders. When you "read" the value of ...

KB868 Troubleshooting DS54 Stationary Decoder Problems

Before sending your Digitrax DS54 stationary decoder in for repair try these steps to see if you can “bring it back from the dead” and save a trip to the shop and possible repair charge.If you find you need to send in an item for repair, click here For Digitrax Repair Procedures and InformationAre there burn marks on the DS54 decoder?You'll need to send it in for repair!Understand CV programming with different throttleCV values shown are 00 or 000 for decimal and x00 for hex. Read your manual carefully to be sure you are using the appropriate values when programming ...

KB354 Programming MRC Sound decoders in OPS mode ('on the Main') using Hexidecimal conversion for CVs 17 and 18

Editor's Note: This tech note has nothing to do with Digitrax SoundFX sound decoders. This is for users who have Digitrax command stations / boosters / etc and wish to program MRC sound decoders. --------------------------- Due to low programming track power in certain dcc systems, programming sound decoders on the program track may not be possible, especially trying to assign the decoder a four, (4), digit address. This programming procedure has to be performed on the mainline, where more power is available for programming sound decoders. If your dcc system allows simple 4 digit address programming on the main, [ops mode ...

KB73 TSMK - Terminal Strip Mounting Kit

The TSMK, Terminal Strip Mounting Kit, includes 2 terminal strip boards with resistors for easy installation. The Digitrax Terminal Strip Mounting Kit makes it simple to connect any scale or model signal to the Digitrax signaling system without soldering. Simply connect the wires from the signal to the TSMK’s screw terminals and plug it in to the SE8C’s Signal Driver Cable. Using the Terminal Strip circuit boards You can attach any of a variety of types of model signal masts in any scale you choose to the Terminal Strip Mounting Kit. The Terminal Strip Mounting Kit has 10 screw terminals ...

KB958 Digitrax Starter Set Comparison

  Zephyr Xtra Super Empire Builder Xtra  Super Chief Xtra Command Station DCS51 DB150 DCS100 Current Rating 3.0 Amps 5 Amps 5 Amps or 8 Amps Throttle DCS51 DT402 DT402 Throttle Controls Single Knob, Direction Switch Dual click encoder throttles Dual click encoder throttles Function Control F0-F28 F0-F28 F0-F28 Keypad Full Numeric Keypad Full Numeric Keypad Full Numeric Keypad Display Large LED Multi-line Backlit LCD Multi-line Backlit LCD Throttle Capacity 20 22 120 Loco Capacity 20 22 120 Loco Address Range 00-9000+ 00-9000+ 00-9000+ Stationary Address Range 01-999 00-999 00-999 Turnout Position Reporting No Yes, last command sent Yes + actual ...

KB628 Performing factory decoder reset using Digitrax DCS100 & DT400 series throttle

Overview:To reset locomotive electronics to factory defaults the user must set CV08 to a value of 08. It is recommended that this procedure be performed on the dedicated service mode programming track using direct mode programming.* Note: This is the only programming procedure that we recommend using the programming track for. All other programming should be performed on the main track using Operations mode programming.Procedure:1. Place the DCC equipped locomotive on a dedicated service-mode programming track.* Note: The rails of this track should be connected to the PROG A & PROG B outputs on the DCS100 command station.2. Set the ...

KB365 Proto 1000 - The Stuff They Don't Tell You

"I had two Proto 1000 RDC's that I wanted to convert. After opening up the first one, I did what I usually do, yanked out all the circuit boards and such, threw them over my shoulder and commenced to hardwiring the decoder into the unit. Everything went fine, and I took it with me to a friend's railroad to enjoy what I had done. After I got there and played a bit, my friend commented that wasn't it neat that the Proto 1000 series has wiring connections on the circuit board in the locomotive, making things considerably easier. Wiring points?" ...

KB266 DB150 Option Switch Table

  Option switches are used to change the operation of the DB150. Option Switch # Effect on system when Option Switch “c” closed Default OpSw 02 Booster Only override t OpSw 03 DB150’s booster is auto reversing t OpSw 05 Default closed for command station –DO NOT CHANGE- c OpSw 13 Loco purge time extended from 200 seconds to 600 seconds t OpSw 14 Loco purging is disabled t OpSw 15 Purging will force loco to Stop or 0 speed t OpSw 17 Automatic advanced decoder assisted [FX] consists are disabled c OpSw 18 Extend the DB150 booster short circuit ...

KB1058 BXPA1 Advanced Setup

 OpSw Setup Enter OpSw mode by pressing the OpSw button.  The OPS and ID light will flash alternating RED and GREEN. Use your throttle in SWITCH mode to set switches to thrown or closed to match your desired OpSw setting.  There are currently no published OpSws for the BXPA1. If you erroneously set an OpSw, the BXPA1 can be factory reset by setting OpSw40 = Closed Trip Speed Pot The Trip Speed Pot can be adjusted to set the speed at which auto reversing and power management is resolved.  Turning the pot clockwise will make the speed slower and turning ...

KB1067 DT602 Throttle Options List

DT602 Throttle Option Settings Throttle ID# Option Name Factory State ID01 Ballistic Knobs With Ballistic tracking, the faster you increase or decrease the throttle knob the faster the data changes in the throttle. When Off the speed step increase is per encoder notch. on ID02 Key clicks Off disables clicks for key press and encoder changes. on ID03 Duplex RF allow Off will turn off Duplex Radio capability. on ID04 IR allow Off will turn off IR capability. on ID05 Fast Clock show On will show fast clock. off ID06 24Hr Clock mode On changes the clock mode from 12Hr ...

KB237 CV29 - Configuration Register - The Addition Method

CV29 sets the characteristics for 5 different decoder behaviors. The table below shows each characteristic and its value if it is on or off. Notice that if the switch is off the value is zero. Click here to go to the automated CV29 value calculatorTo determine the value to program for your decoder just go down the list and add up the numbers for all the switches you want to set as ON. If you need to convert the decimal valueCV29 Examples of CV Values: The factory default value for CV29 is 06. Switch # Characteristic if OFF Value if ...

KB923 CV19, CV21, CV22 - Advanced Consist Address/Function Controls

Most customers that use Digitrax command stations use Universal Consisting instead of Advanced Consisting as described here.  With Universal consisting, the consist information is handled by the command station instead of by the decoder.CV19 is the advanced consist address. CV19 also contains data for the direction in which the consist will operate. See the table below to determine what value to program into CV19 CV19 Value Effect on Adv Consist Address Normal Direction of Travel of Advanced Consist 000 Advanced Consist Addressing Disabled N/A 001 - 127 Advanced Consist Addressing Enabled Forward 129 - 255 Advanced Consist Addressing Enabled Reverse When ...

KB239 CV29 - Look-Up Table Method

The look up table below shows the results of different CV values that you can program into CV29. CV values are shown in both hex & decimal. In practice, most Digitrax operators now only use decimal. CV29 Values: The factory default value for CV29 is 06. CV Value For CV29 Hex   Dec Speed Steps/ Speed Table Analog Mode Conversion Normal Direction Of Travel 2 or 4 Digit Address x00 000 14 OFF Forward 2 x01 001 14 OFF Reverse 2 x02 002 28/128 OFF Forward 2 x03 003 28/128 OFF Reverse 2 x04 004 14 ON Forward 2 x05 005 ...