Supporting Documentation

Product Support for: Power Supplies -> AC/DC Adapter 14V DC 300ma (PS14)

View the Product Page for the PS14

The PS14 is a 300ma, 14 Volt power supply for powering Digitrax accessories like the UP5, BDL168, DS64, SE8C, LNRP, UR90, UR91, UR92 and others

27 Articles Found for PS14

KB89 PM42 - Powering with PS14

The installation instructions indicate that a PS14 be used to power the PM42. Is it necessary that I cut the wire from the PS14 so that is can be attached it to the 44-pin connector, or is there a male adapter available for the connection? Yes, currently you will need to cut the wire, strip the ends and solder them to the edge connector of the PM42. Please see the related articles below. Which lead from the PS14 is to be soldered to terminal 3 on the 44-pin connector and which is to be soldered to terminal C? The PM42 ...

KB590 Q&A - Powering DS64

  Q:  How do you connect more than one DS64 to a single power supply like a PS14 to power them or do you need a separate power supply for each DS64? A:  One power supply can be used if it can provide adequate power for all the DS64s it is powering. The PS14 has a built-in circuit breaker; when it exceeds its capacity, it will shut down, cool off and then start up again. If you are experiencing this behavior then you need to add one or more PS14s to provide enought power for the DS64s you have connected. Our recommendation of one ...

KB268 Powering the SE8C

What are the power requirements of a SE8C? Any power supply that can provide 12-15 volts either AC or DC with a minimum current rating of 100 ma is all that is necessary to power a single SE8c. Digitrax recommends the PS14 for powering the SE8c. A single PS14 has the ability to power two SE8c’s. When connecting multiple SE8c’s to a single power source the total maximum current requirement of the power source is computed by multiplying the number of SE8c modules by 100 ma (Example: 3 SE8c’s would require a 300 ma power supply - 3x100=300). The edge ...

KB1017 LocoNet Accessory Power Requirements

  This document outlines the power requirements for Digitrax LocoNet accessories.  To simplify wiring, Digitrax recommends providing individual power supplies for like accessories.  For example a power supply or power buss which only powers the PM42s.  A power supply or power buss used solely to power multiple DS64s.  UR9x and UP5 panels can be daisy chained provided adequate current is provided to properly power all the panels.  Through the use of individual power supplies, the chance of Ground Loops or sneak paths back to ground is minimized.  Using individual power supplies will also make troubleshooting much easier.  Many Digitrax LocoNet ...

KB971 PM42 - Power Input Requirements

Can I combine the power input requirements for PM42's with other units for economy?Digitrax recommends each PM42 module to have its own seperate power source. The criteria for choosing a power supply for the PM42 is any power source that can deliver 12-15V AC or 13.8-15V DC with a minimum of 125 ma. The Digitrax PS14 meets the minimum power requirement of a PM42.It is possible to power more than one PM42 from a single power source. When powering multiple PM42's special care must be taken to insure identically phasing of all PM42's and ample current availability to power all ...

KB702 UP5 Power Supply and Track Indicator Connections

Hooking up the UP5's Power Supply (Optional but highly recommended to make sure LocoNet voltage is adequate to control large layouts)The optional power supply (PS14) can be connected to one or more UP and/or UR panels to provide additional power for LocoNet operation and for battery saving power to any Digitrax throttle that is plugged into any of the powered panels.1. Plug the PS14 into the DC jack located on the side of the UP5 circuit board.2. Connect the +Common point on each additional board (located between the two LocoNet jacks) to the powered board with 22AWG wire (Figure 2). ...

KB567 DS54 Power Options

  There are two methods of providing power to the DS54: from the rails and from an auxiliary power source. The DS54 can be powered from the rails however, Digitrax strongly recommens that the DS54 be powered from an auxiliary power supply capable of delivering 12-16 volts (ac or dc) at 300 millamperes for best results.  Powering the DS54 from the rails reduces the current available to power locomotives and lighted rolling stock.  The auxiliary power supply connections are the red (+) and black (-) wires. Note: Digitrax recommends the PS14 Power Supply for independently powered DS54’s. Multiple DS54’s can be powered from a single power ...

KB195 PR3 - Hardware Setup

SoundLoader and PR3 have been tested to work on PC compatible computers running at 550MHz and up with Windows XP or Vista, 512MB of RAM. Other combinations of hardware and software such as Windows 98 may also work, but are not supported by Digitrax, and have not been tested to operate properly. Installation consists of three steps: Hardware installation, software installation, and software setup. Below is a photograph of the actual hardware connections required for SoundFX programming. Assemble the PR3 hardware as shown in the diagram below and connect to an appropriate power supply (Digitrax PS14 or equivalent). Note the ...

KB1013 PR3 Xtra Support Portal

The PR3 Xtra is a bundle including the PR3 and the PS14 power supply, please go to the one of the following pages for support you need: PR3 PS14

KB1014 LNRP Xtra Support Portal

The LNRP Xtra is a bundle including the LNRP and the PS14 power supply, please go to the one of the following pages for support you need: LNRP PS14

KB352 Powering your Digitrax Command Control Railroad

Digital Command Control (DCC) has specific electrical requirements that must be provided for your layout control system to operate properly.Input PowerAll DCC systems require an external power supply.  Digitrax manufactures several power supplies for our command stations and boosters: The 3 Amp PS415 (the Zephyr Xtra power supply) The 5 Amp PS515 for all Digitrax 5 amp command stations and boosters The powerful 20 Amp PS2012 can be used for multiple 5 and 8 amp command stations and boosters  Additionally, the PS14 is available to power various other devices for your railroad.  Digitrax strongly encourages you to use our power supplies to insure satisfactory ...

KB701 UP5 Layout Installation and LocoNet Connection

1. The UP5 Universal Panel is designed for mounting on the fascia board of the layout. Cut a hole approximately 2.5” W x 1.5” H in the fascia board. Insert the UP5 through the hole with the face plate on the front of the fascia board. Attach the UP5 face plate to the fascia board with four #6 screws. Note: The UP5 uses the black screws to mount the front fascia plate.2. Connect the UP5 to LocoNet using pre-tested LocoNet cables. There are 2 LocoNet Jacks located at the back of the UP5 board for connecting LocoNet devices on your layout. ...

KB171 PR3 - Stand Alone LocoNet Interface Applications

Under what conditions can the PR3 be used as a Stand Alone LocoNet Terminator? The PR3 is so designed so that it can be configured to act as a stand alone LocoNet controller in the event that a Digitrax command station is unavailable for the control of a series of LocoNet compatible devices. There are two major situations that would require the PR3 to act as a stand alone LocoNet controller. The first situation is where one of the many advanced features offered by the LocoNet and the various LocoNet compatible devices is desired to be used on a layout ...

KB1061 Powering the PR4

The PR4 will only “light up/power ON” when it is connected to a computer via USB.  Simply connecting the PS14 will not power the device and cause any lights to come on. Please follow the complete PR4 installation instructions consisting of PR4 Driver and Software Installation and PR4 Hardware Installation to power and test your PR4. Using the PS14 power supply is only required when using the PR4 for Sound/Decoder programming.

KB814 Powering DS64

  There are three different ways to power the DS64.  Track power (Trk A and Trk B), Auxiliary power (AX1(-) and AX2(+)) and power through the rear modular power connector.  Connect the Trk A and Trk B screw terminals of the Power and Track Connections to the corresponding Rail A and Rail B track connections.  The PS14 power supply can be used with Auxiliary or the rear modular power connector.  The DS64 requires 300mA for proper operation.  Only one DS64 can be powered per PS14.  A generic DC power supply between 12-16vdc and 300mA can be connected to a DS64 ...

KB38 UR92 - Resetting Factory Defaults

Resetting Factory Defaults You are unlikely to encounter a problem that will require a factory reset. One such instance may occur if you set a password for your Duplex Group name and forget what it is. Resetting to factory default condition is an easy way to correct the situation. Note: If you have more than one UR92 in your layout, you will want to disconnect all of them to do a full factory reset on each unit as follows. Once they have been reset, reconnected to your LocoNet, and allowed to renegotiate a common Group name; you can change the ...

KB277 Powering LNRP

I have purchased an LNRP, UR90, and 4 UP5s. I have noticed the LNRP seems to have a solder point between the two LocoNet jacks as the UR90 and UP5.Can all of these be connected to the same 12 volt power supply? No. It is important that each LNRP has its own power supply. As noted in the documentation that comes with the unit, "the LNRP drives the power and Railsync signals on the standard LocoNet cable segments, so each LNRP should have a DC input of +12V to +18V at up to 250mA supplied on the side DC power ...

KB359 LNRP - Q&A

1) Does the LNRP terminate and re-time the LocoNet data signal in both directions? Yes 2) Does the LNRP repower the LocoNet data lines for each segment? Yes 3) What happens to the signal on a protected segment when there is a fault on an adjacent segment? Nothing, it keeps going 4) What happens RailSync on a protected segment when there is a fault on an adjacent segment? Nothing, it keeps going 5) What do the various diagnostics/error indicators really do? They monitor and report the protected sides. A Digitrax PS14 power supply is required for correct operation.

KB1031 Duplex Troubleshooting

  Digitrax Duplex Wireless Functional diagnosis and debug process:   Duplex Background:  The Digitrax Duplex radio system is a two-way RF radio link connecting wireless throttles (DT402D & UT4D) via a UR92 onto LocoNet.  It operates on one of 16 user-selected channels in the 2.4GHz Wi-Fi frequency band.  FCC rules requires that all WI FI devices including the RF24 Duplex transceivers (part of Digitrax Duplex throttles and the UR92) operate co-cooperatively in this 2.4GHz band and have to accept whatever wirelessenvironment is present.  This means that there is no guarantee that Digitrax Duplex will work in all situations or that it will ...

KB41 UR92 - Installation/Quick Start

The UR92 is simple to install and begin using in your new or current layout. 1. In most cases a UR92 should be situated near the physical center of a layout and will typically cover a circle of about 300+ feet (~100 meters) across, which will be adequate for most layouts. Some layouts may require additional UR92s for adequate signal coverage. 2. Connect the PS14 DC power supply to UR92 via the DC power jack on the side. The green and red LEDs should blink and then the red LED should stay on. 3. Connect the UR92 to your working LocoNet ...

KB486 PM42 - Programming Op Switches with a DT400 series throttle

Q:  How do I program the PM42 Option Switches (OpSw) with a DT400 throttle? A:  The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSws is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the DT400 series throttle with any Digitrax command system. 1) Connect the PM42 to a DCS50, DCS51, DB150, DCS100, or DCS200 with a standard LocoNet cable. 2) Connect the PM42 to an external power source; Digitrax ...

KB487 PM42 - Programming Op Switches with a DT300 Throttle

  Q:  How do I program the PM42 Op Switches with a DT300 throttle? A:  The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSws is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the DT300 throttle with any Digitrax command system. 1) Connect the PM42 to a DB150, DSC050, DSC100 or DSC200 with a standard LocoNet cable. 2) Connect the PM42 to an external power source; Digitrax recommends the ...

KB488 PM42 - Programming Op Switches with a Zephyr (DCS50 or DCS51)

  How do I program the PM42 Op Switches with a DCS50 (Zephyr) throttle? The PM42 OpSw settings are used to set up the PM42, adjusting the trip current, short circuit management (including sensitivity), and/or auto-reversing. Note: The factory default setting on all PM42 OpSw's is “thrown” or “t”. Follow the steps outlined below to program the OpSw settings of the PM42 using the keypad of a Digitrax Zephyr. 1. Connect the PM42 to the Digitrax Zephyr with a standard LocoNet cable. 2. Connect the PM42 to an external power source; Digitrax recommends the PS14. Note: Before entering Switch Mode ...

KB72 Cajon Pass, Salt Lake & Santa Fe RR

I am putting the finishing touches on my 10 x 20 foot H0 railroad. It is a copy of the Cajon Pass, Salt Lake & Santa Fe RR by John Armstrong (#86 in the 101 Track Plans by Linn Westcott) [Kalmbach Publishing, ISBN 0-89024-512-6; still in print]. I have decided to go with DCC and my local hobby store recommended Digitrax. The layout is in my basement, I will be the only operator, the plan has 54 track switches (34 NJ International twin coils and 20 Tortoise turnout motors). Can you give me an idea as to what equipment I ...

KB84 SE8C - Initial Setup & Testing

We recommend testing your new SE8C prior to installation on your layout. The following testing procedures will help familiarize you with the general operation of the SE8C. Track power needs to be ON, a working LocoNet connection and a throttle or PC running DCC control software. Pre-Installation Set-Up 1. Solder one wire from a 12V AC or 15V DC power supply to Pin 3 and the second wire from the power supply to the Pin C on the 44-Pin edge connector; this powers the SE8C. Digitrax manufactures the PS14, which is appropriate for this installation. Multiple SE8Cs can be powered ...

KB714 Loconet Overview

LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout.  LocoNet compatible devices are designed to work together on the network, and in some cases can also accept DCC commands from  the track, but often go beyond the scope of simple DCC train control.   LocoNet is a peer-to-peer Ethernet type multiple access network.  Because of its design architecture, it is very robust and powerful.  Layout implementation is simple and wiring is free form with minimal limits. LocoNet is designed to run an unshielded 6 conductor ribbon cable.  Digitrax recommends using flat, six-conductor telephone wire ...

KB1063 IPLing and Track Power with the DT602/D

IPLING From time to time the latest DT602 family throttle firmware will be updated and will be posted on the product support page.  These updates may slightly modify the DT602's operation, based on customer feedback/requests and priority support issues discovered. If you are happy with the operation of your DT602, and have no issues or new features you may want, it is not required to perform an available update. All DT602 family throttles should only be firmware updated or IPL'd while plugged directly into a working LocoNet. The Digitrax provided DMF file for field updating DT602's can be used for IPL of any ...