KB507 SE8C - Signals On Non-DCC Layouts

Q: I would like to know about SE8C and signals on non-DCC layouts. A:  The SE8c is a signal driver for your layout. You can operate signals manually with any LocoNet Throttle and Command Station. Or, in your case, the SE8c can drive signals automatically with detection and compatible computer software such as RailRoad & Co. or JMRI.You will need detection devices to identify the presence of trains, a computer interface such as the PR3, a computer program supplying the signaling logic and the SE8c driving the signal heads themselves. Note that in a LocoNet environment, the SE8C supports detection: DS01 ...

KB614 BDL168, PM42 & SE8C Recommended Wiring Procedure For 44 Pin Connector

  Do you have a recommend wiring procedure for the 44-pin edge connector on the PM42 and SE8C?PM42, PM4, BDL168, BDL16, BDL162 & SE8C use a 44-pin edge connector. Connecting wires securely to this connector requires soldering skills. For connections to the 44 pin connector, Digitrax recommends using 16 gauge stranded wire. For all other soldering connections, Digitrax recommends 14 gauge (AWI) stranded wire for electrical connections on your railroad. 1. Use individual short lengths of 16 gauge wire to connect to the 44 pin connector. 2. Strip and tin both ends of the wire. 3. Bend one end into ...

KB230 BDL168 - Power Districts and Transponding

Is it possible to add a pair of PM42 Power Management Modules between the command station Rail A/Rail B outputs and run the resulting output from the PM42's on as many as 8 sets of Rail A/Rail B Wires to 8 isolated power Zones? These isolated power zones could have their Common Zone (Rail A) Wires running through RX1 transponding receivers connected to an RX4 ribbon cable running to the BDL168 for the purpose of interfacing with the SurroundTraxx Multi-Train Sound System. If this is possible, it would only require 5-6 of the DS lines on the BDL168 to be ...

KB904 BDL16x Series-Detection-Planning Worksheet

RX4 / BDL168 Hookup Worksheet BDL168 #_______ Address:________ Description______________________________________________________ Aux Power:_______ Standard BDL162 Configuration Advanced Detection Section Wiring: Transponding Method________________________________   Section Pin # Named Detection Section Description ZONE A Power In 1       1 2     Power 2 3     District 3 4       4 5     In Out Alternate Zone Comments                                             ZONE B Power In 6       5 7     Power 6 8     District ...

KB905 BDL162 - Increase Detection Section Threshold Sensitivity

How do I Increase BDL162 Detection Section Threshold SensitivityThe BDL162 has Option Switch settings to control detection sensitivity. The factory setting is OpSw19=t for a threshold sense for DCC occupancy of approximately 22 Kohms minimum. Changing OpSw19=c will set the threshold to 10 Kohm minimum. See the BDL162 instruction manual for details on setting the Option Switches. These settings will accommodate most layouts, though there may be circumstances when a higher threshold is desired, for example, in a high moisture environment or with G scale operations outside.To raise the threshold even further resistors can be added into the wiring between ...

KB588 BDL168 - LT5 Tester

There was an error In the BDL168 Instruction Sheet, Figure 6 on Page 19.  The LT5 diagram was incorrect.  This article shows the correct LT5 Detection Sections.  The current on-line version of the BDL168 Instruction Sheet has been corrected. Each BDL168 comes with an LT5 that will help you with layout wiring and troubleshooting for transponding & detection. The LT5 plugs onto the LED header connections of BDL168 and the LEDs on the LT5 light when detection sections are occupied. The status of power to each zone is also shown. In service, the LT5 is plugged in to one of ...

KB80 SE8C - Detection Inputs

Detection Section Inputs DS01 to DS08 (see below) are inputs from occupancy detectors that provide at least +5V (max 22V) when occupied, and 0V when unoccupied. The SE8C sends occupancy messages to LocoNet when these inputs change. If these detection section inputs are not disconnected, they will report “unoccupied”. Occupancy reporting can be turned off by changing OpSw 13 to closed.

KB497 BD4 - Connecting to an SE8C

  Connecting BD4 to an SE8C?The BD4 is a block occupancy detection device designed as an add-on device that can take advantage of the LocoNet hosting capability of the SE8c signal decoder.   It is connected this way: The installation of a BD4 is relatively simple. Looking at the BD4, you will find a 5-point terminal block on one end and two (LED1 and DS1) 10-pin (5x2) headers on the other. There are three termination areas: a) The 5-point terminal block (left) is for the interconnection between the rail power source and the rails. b) The LED1 10-pin header is ...

KB594 Is Digitrax signaling and detection equipment compatable with other DCC systems?

Q: I have a Lenz Set 100 and was wondering if I can use my DCC system and use the Digitrax signaling and detection components. What about other DCC systems?A: Yes, Digitrax detection and signaling will work with any DCC system.  You will need to install a LocoNet network for the LocoNet components to communicate with each other and use a PR3 or MS100 to interface with a computer running software such as Railroad and Co. 

KB968 Common Rail Track Detectors With Digitrax

We have a number of customers who are running Digitrax alongside their existing block detection circuitry. There are numerous block detection schemes and circuits, and we cannot cover all the variations here. Generally, it is necessary to isolate the block detector power supply and ground system of your existing block detector system from that of the Digital boosters. The most common detectors use "back to back" high current diodes to sense block current-draw. Detectors with "opto-isolated" or relay outputs will generally have no problem sensing current draw of a loco, etc., on the DCC current, and will signal the occupancy ...

KB54 BDL168 - Troubleshooting Checklist

Here are several things to check if you are having trouble with the BDL168: Proper Wiring Be sure that you have NOT connected pin 11 to pin M, as this can prevent proper LocoNet communication. Check to make sure not wires are touching adjacent pins.  Follow the wiring diagram closely. Packet Reception Be sure the green ID LED is ON & is “winking” off about every 2 seconds. This means that correctly formatted DCC packets are being decoded from the left most (Railsync) pin of the RJ12 LocoNet socket. For DCC detection, the same DCC packet signal that drives the ...

KB56 BDL168 - 44-Pin Connector Pinout Configuration

BDL168 Pin Out Configuration: Notes: 1) All connector pins are paired top (component side of the BDL168) and bottom (solder side of the BDL168) except 11/M and 12/N. For 6 Amp current rating with 3 Amp connector pins, track/zone wires must be connected to both pin pairs: e.g. Zone A = pins 1 & A (See Figure below): 2) Letters G, I, O & Q are not used as pin designations on the connector. 3) Power connections should be made to a power supply dedicated to BDL168 use only. Multiple BDL168 units can be supplied by a single shared supply ...

KB58 BDL168 - Connecting to a "Direct Home" Wired Layout

Direct Home Layout Wiring Digitrax strongly recommends direct home wiring where each power district and its booster are electrically isolated. This method of wiring has safety advantages and makes troubleshooting problems easier. In addition, direct home wiring makes detection work more prototypically. With direct home wiring, the BDL168 can determine and indicate whether any of its 4 zones is powered or not (possibly short-circuited) even when there is nothing on the rails in the detection sections. The BDL168 factory-set logic causes the detection sections to show "occupied" if the associated zone's power is off (because in this case, detection is ...

KB411 AR1 with BD4 for Block Detection

How do you wire an AR1 with a BD4 so that you get block detection within the reverse loop and without the BD4 permanently detecting the AR1? It should be wired with the AR1 between the power source and the BD4. All four detection sections of the BD4 will have to be inside the reverse loop.

KB61 BDL168 - Using two boosters

Is it possible to connect my BDL168 across two power districts (Boosters). I envisage using zone 1 & 2, with detection sections 1-8 one one booster (DCS100), with zones 3 & 4, with detection sections 9-16 on another booster (DB150). Will this work? Please refer to the chart below: Note that Pins 1 & A, 6 & F, 13 & P, and 18 & V are identified as "Connection to Booster for Zone *. Each Zone can support up to four detection sections. So, for your application, the DCS100 would be connected to Pins 1 & A and 6 & ...

KB607 Resistance wheel sets

Railroad signaling works based on detection of trains on the railroad.  If a train is detected, then the signal system goes into action, setting up indications that let show that the track section is occupied and warn other trains that the section is occupied.  At a grade crossing where a railroad and a highway intersect, the presence of a train starts the crossing signals and lowers the gates in time to stop highway traffic so the train can pass.In the case of real railroads, detection is easy, since the rails are naturally insulated from each other and either a locomotive or ...