KB228 AC wall Power in Japan

I am thinking of buying your "Radio Equipped Super Chief Premium Set", and I understand it is recommended that I use the PS-515 as a power supply. Your product specifications for the PS-515 say that it should be plugged into a wall outlet (AC 120V, 60Hz). I live in Japan and the AC power supply is 100V and 50Hz. I wonder if this difference in voltage and frequency poses any big problem in using a "Radio Equipped Super Chief Premium Set" here in Japan. The lower voltage input is not related to the voltage output necessary for the Super Chief ...

KB590 Q&A - Powering DS64

  Q:  How do you connect more than one DS64 to a single power supply like a PS14 to power them or do you need a separate power supply for each DS64? A:  One power supply can be used if it can provide adequate power for all the DS64s it is powering. The PS14 has a built-in circuit breaker; when it exceeds its capacity, it will shut down, cool off and then start up again. If you are experiencing this behavior then you need to add one or more PS14s to provide enought power for the DS64s you have connected. Our recommendation of one ...

KB326 DCS100 and DB150 - Power Supply

The two "POWER IN" terminals on all Digitrax boosters & command stations are the power input connections. Digitrax recommends the PS514 to power the DC200 and DB150.  Set the voltage setting on the PS514 to 16.8v or 19v.  The PS2012 can also be used to power the DCS100 and DB150.  The "Y" cable provided with the PS2012 has an embedded 5 amp current protection.  The PS2012 can also be used to power the DCS200.  The "Y" cable is not suitable for use with the DCS200 since it has an 8 amp. output. When powering your layout, make sure that all polarities and ...

KB89 PM42 - Powering with PS14

The installation instructions indicate that a PS14 be used to power the PM42. Is it necessary that I cut the wire from the PS14 so that is can be attached it to the 44-pin connector, or is there a male adapter available for the connection? Yes, currently you will need to cut the wire, strip the ends and solder them to the edge connector of the PM42. Please see the related articles below. Which lead from the PS14 is to be soldered to terminal 3 on the 44-pin connector and which is to be soldered to terminal C? The PM42 ...

KB379 Super Empire Builder Power Requirements

The answer to this question applies to all Empire Builder sets including Super Empire Builder XtraQ:  I have just purchased a Super Empire Builder set. My expectations are for it to operate an N-Scale switching layout right now with future expansion to a larger N-Scale layout. I am a little confused as to which power supply I would need at this time. I am reading about power supplies and inline fuses, all of which is a little overwhelming to me as I am getting back into the hobby. Can you recommend which power supply will be better for me as ...

KB268 Powering the SE8C

What are the power requirements of a SE8C? Any power supply that can provide 12-15 volts either AC or DC with a minimum current rating of 100 ma is all that is necessary to power a single SE8c. Digitrax recommends the PS14 for powering the SE8c. A single PS14 has the ability to power two SE8c’s. When connecting multiple SE8c’s to a single power source the total maximum current requirement of the power source is computed by multiplying the number of SE8c modules by 100 ma (Example: 3 SE8c’s would require a 300 ma power supply - 3x100=300). The edge ...

KB702 UP5 Power Supply and Track Indicator Connections

Hooking up the UP5's Power Supply (Optional but highly recommended to make sure LocoNet voltage is adequate to control large layouts)The optional power supply (PS14) can be connected to one or more UP and/or UR panels to provide additional power for LocoNet operation and for battery saving power to any Digitrax throttle that is plugged into any of the powered panels.1. Plug the PS14 into the DC jack located on the side of the UP5 circuit board.2. Connect the +Common point on each additional board (located between the two LocoNet jacks) to the powered board with 22AWG wire (Figure 2). ...

KB1007 PS2012 - Overview and Installation

Regulated power supply delivers more power with less heat for more efficient booster operation. Operates up to 4 Five amp boosters. Scale selectable for use with N, HO or large scale. DC Ammeter. On/Off Switch. Integral cooling fan. Design coordinated for use with Digitrax products. One "Y" Cable (P/N YC52) Included for convenience with dual 5 amp protected outputs All secondary devices must be properly fused on their power input leads for their rated capacity. For example if you intend to use the PS2012 to drive a 5 and an 8 amp booster, you must input fuse these devices for ...